Instruction/ maintenance manual of the product 7510 DSU Paradyne
Go to page of 69
MODEL 7510 DSU USER’S GUIDE Document No. 7510-A2-GB20-10 November 1997.
Printed on recycled paper A 7510-A2-GB20-10 November 1997 Copyright 1997 Paradyne Corporation. All rights reserved. Printed in U.S.A. Notice This publication is protected by federal copyright law .
i 7510-A2-GB20-10 November 1997 Contents About This Guide Document Purpose and Intended Audience v . . . . . . . . . . . . . . . . . . . . . . . . . Document Summary v . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Contents ii 7510-A2-GB20-10 November 1997 4 Monitoring the DSU What to Monitor 4-1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Viewing System and T est Status 4-2 . . . . . . . . . . . . . .
Contents iii 7510-A2-GB20-10 November 1997 A Configuration Option T ables Overview A-1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . System Options Menu A-2 . . . . . . . . . . . . .
v 7510-A2-GB20-10 November 1997 About This Guide Document Purpose and Intended Audience This guide contains information needed to set up, configure, and operate the Model 7510 DSU and is intended for installers and operators. Document Summary Section Description Chapter 1 About the DSU.
About This Guide vi 7510-A2-GB20-10 November 1997 Section Description Glossary Defines acronyms and terms used in this document. Index Lists key terms, acronyms, concepts, and sections in alphabetical order .
1-1 7510-A2-GB20-10 November 1997 About the DSU 1 Model 7510 DSU Featur es The DSU provides an interface between the customer premises equipment (CPE) and a Digital Data Service (DDS) network. The DSU’s features and capabilities include: Easy Installation.
About the DSU 1-2 7510-A2-GB20-10 November 1997 T ypical DSU Configurations The following illustration shows a typical LAN/W AN interconnection application for the DSU. The routers connected to the DSU at each location provide the LAN interconnection.
About the DSU 1-3 7510-A2-GB20-10 November 1997 User Interfaces There are two types of user interfaces for the DSU: Menu-driven Asynchronous T erminal Interface (A TI) screens (see Chapter 2, Using the Asynchronous T erminal Interface ). Front panel LED status indicators (see Chapter 4, Monitoring the DSU ).
2-1 7510-A2-GB20-10 November 1997 Using the Asynchr onous T erminal Interface 2 Connecting to the T erminal Port The device used for the Asynchronous T erminal Interface (A TI) can be a VT100-compatible async terminal, or a PC running emulation software.
Using the Asynchronous T erminal Interface 2-2 7510-A2-GB20-10 November 1997 Initiating an A TI Session The user interface is blank until activated. Press Return to activate the user interface. The first time you do this the Main Menu screen is displayed.
Using the Asynchronous T erminal Interface 2-3 7510-A2-GB20-10 November 1997 Configuration Edit/Display • System • Network • Data Port • T erminal Port Status • System and T est Status • N.
Using the Asynchronous T erminal Interface 2-4 7510-A2-GB20-10 November 1997 Screen W ork Areas There are two user work areas: Screen area – This is the area above the dotted line that provides the menu path, menus, and input fields. The menu path appears as the first line on the screen.
Using the Asynchronous T erminal Interface 2-5 7510-A2-GB20-10 November 1997 Navigating the Scr eens Y ou can navigate the screens by: H Using keyboard keys H Using screen function keys H Switching between the two screen work areas Keyboard Keys Use the following keyboard keys to navigate within the screen.
Using the Asynchronous T erminal Interface 2-6 7510-A2-GB20-10 November 1997 The current setting or value appears to the right of the field name. The valid choices for the field are displayed in the screen function area. Y ou can enter information into a selected field by typing in the first letter or letters of a field value or command.
Using the Asynchronous T erminal Interface 2-7 7510-A2-GB20-10 November 1997 Switching to the Screen Function Key Ar ea Selecting Ctrl-a allows you to switch between the two screen work areas to perform all screen functions. Procedur e T o access the screen function area below the dotted line: 1.
Using the Asynchronous T erminal Interface 2-8 7510-A2-GB20-10 November 1997 Ending an A TI Session Use the E xit function key from any screen to terminate the session. Procedur e T o end an A TI session: 1. Press Ctrl-a to go to the screen function key area below the dotted line.
3-1 7510-A2-GB20-10 November 1997 Customizing the DSU 3 Identifying the Device and System Use the Device Name screen to determine the name that will be displayed at the top of all A TI screens, and system information that will be displayed on the Identity screen.
Customizing the DSU 3-2 7510-A2-GB20-10 November 1997 Procedur e T o enter Device Name screen information: 1. Position the cursor in the Device Name field. Enter a name unique in your system to identify the unit. The maximum length of Device Name is 20 characters.
Customizing the DSU 3-3 7510-A2-GB20-10 November 1997 Configuring the DSU Configuration option settings determine how the DSU operates. Use the DSU’s Configuration branch to display or change configuration option settings. Configuration Option Areas The DSU is shipped with factory settings in the Default Factory configuration area.
4-1 7510-A2-GB20-10 November 1997 Monitoring the DSU 4 What to Monitor This chapter presents information on how to access and monitor DSU status and performance statistics on the DDS network.
Monitoring the DSU 4-2 7510-A2-GB20-10 November 1997 V iewing System and T est Status T o view System and T est Status information, follow this menu selection sequence: Main Menu → Status → System.
Monitoring the DSU 4-3 7510-A2-GB20-10 November 1997 Health and Status The following messages appear in the first column of the System and T est Status screen. The highest priority Health and Status message also appears on all A TI screens on the bottom right.
Monitoring the DSU 4-4 7510-A2-GB20-10 November 1997 T able 4-2. Health and Status Messages (2 of 2) Message What T o Do What Message Indicates Device Fail yyyyyyyy An internal error has been detected by the operating software. yyyyyyyy indicates the 8-digit hexadecimal failure code.
Monitoring the DSU 4-5 7510-A2-GB20-10 November 1997 T est Status Messages The T est Status Messages in the following table appear in the right column of the System and T est Status screen. T able 4-4. T est Status Messages T est Status Message Meaning No T est Active Status message, indicating no local, remote, or network test in progress.
Monitoring the DSU 4-6 7510-A2-GB20-10 November 1997 V iewing Network Interface Status The network interface status fields are read-only: Line Rate (Kbps) .
Monitoring the DSU 4-7 7510-A2-GB20-10 November 1997 V iewing Network Performance Statistics Performance statistics for the network interface are available to: Monitor the current status of the network operations. View the DSU’ s performance statistics, which: — Assist you in determining the duration of specific conditions.
Monitoring the DSU 4-8 7510-A2-GB20-10 November 1997 Monitoring the LEDs The status of DSU LEDs can be viewed on the Display LEDs screen. The 12 LEDs are organized into three groups: System LEDs d.
Monitoring the DSU 4-9 7510-A2-GB20-10 November 1997 System LEDs 496-1506 2 CTS (106) OK ALARM TEST DM OOS OOF NS TXD (103) RXD (104) RTS (105) DTR (108) Network System Por t red green yellow OK: ON – DSU is operational. OFF – DSU is performing a power-up self-test, has detected a system failure, or there is no power .
Monitoring the DSU 4-10 7510-A2-GB20-10 November 1997 Network LEDs 496-1506 2 CTS (106) OK ALARM TEST DM OOS OOF NS TXD (103) RXD (104) RTS (105) DTR (108) Network System Por t red green yellow DM – Data Mode: ON – DSU (DDS network interface) is sending or receiving data, or is in DMI condition (all 1s being received).
Monitoring the DSU 4-1 1 7510-A2-GB20-10 November 1997 Port LEDs 496-1506 2 CTS (106) OK ALARM TEST DM OOS OOF NS TXD (103) RXD (104) RTS (105) DTR (108) Network System Por t red green yellow TXD – T ransmitted Data: ON – Receiving all 0s from the DTE.
5-1 7510-A2-GB20-10 November 1997 T esting 5 Accessing the T est Menu From the T est menu, you can run network tests, data port tests, and a lamp test for the front panel LEDs.
T esting 5-2 7510-A2-GB20-10 November 1997 Loopbacks can be started from a variety of points in the network, as shown in T able 5-1. T able 5-1. Device Messages Loopback T ype Initiated By Notes Bilateral Loopback User Remote unit sending V .54 sequence When enabled, running a DSU loopback also automatically starts a local loopback.
T esting 5-3 7510-A2-GB20-10 November 1997 Running Network T ests Network tests require the participation of your network service provider . T o access the Network T ests screen, follow this menu sele.
T esting 5-4 7510-A2-GB20-10 November 1997 CSU or External Network Loopback CSU loopback is an external loopback that is located as closely as possible to the network interface. Procedur e T o run a CSU loopback: 1. Position the cursor at the Start command next to CSU Loopback on the Network T ests screen.
T esting 5-5 7510-A2-GB20-10 November 1997 DSU or Internal Network Loopback DSU loopback is an internal loopback that is located as closely as possible to the customer interface serving the DTE. " Procedur e T o run a DSU loopback: 1. Position the cursor at the Start command next to DSU Loopback on the Network T ests screen.
T esting 5-6 7510-A2-GB20-10 November 1997 51 1 T est Pattern for the Network This test sends or monitors the 51 1 test pattern over the network interface. Procedur e T o run a Send 51 1 test: 1. Position the cursor at the Start command next to Send 51 1 on the Network T ests screen.
T esting 5-7 7510-A2-GB20-10 November 1997 Running Data Port T ests For an example of the fields on a test menu screen, refer to Running Network T ests on page 5-3.
T esting 5-8 7510-A2-GB20-10 November 1997 Local Loopback Local Loopback loops the user data back to the DTE. This loopback is located as closely as possible to the User Data Port (DTE) interface. Procedur e T o run a local loopback: 1. Position the cursor at the Start command next to Local Loopback on the Data Port T ests screen.
T esting 5-9 7510-A2-GB20-10 November 1997 Procedur e T o run a Monitor 51 1 test: 1. Position the cursor at the Start command next to Monitor 51 1 on the Data Port T ests screen. 2. If desired, use Ctrl-a to switch to the screen function key area and use the virtual function key r or R (R esetMon) to clear the error counter to zero.
T esting 5-10 7510-A2-GB20-10 November 1997 Ending an Active T est A test initiated by the user can be ended by the user . A T est Timeout option is available to automatically terminate a user-initiated Loopback or Pattern test after it has been running a specified period of time.
6-1 7510-A2-GB20-10 November 1997 Messages and T r oubleshooting 6 Messages and T roubleshooting There are many messages available to assess the status of the device and contribute to problem resolutions.
Messages and T roubleshooting 6-2 7510-A2-GB20-10 November 1997 T able 6-1. Device Messages (2 of 2) Device Message What T o Do What Message Indicates Invalid T est Combination A loopback or 51 1 pattern test was in progress when Start was selected to start another test, or was active on the same or another interface when Start was selected.
Messages and T roubleshooting 6-3 7510-A2-GB20-10 November 1997 T roubleshooting This DSU is designed to provide you with many years of trouble-free service. If a problem occurs, however , refer to T able 6-2 for possible solutions. T able 6-2. T roubleshooting (1 of 2) Symptom Possible Cause Solutions Alarm LED is on.
Messages and T roubleshooting 6-4 7510-A2-GB20-10 November 1997 T able 6-2. T roubleshooting (2 of 2) Symptom Solutions Possible Cause Not receiving data; DSU is not responding. DDS line rate/speed has changed. Excessive BPVs causing DSU to become stuck in Autobaud mode.
A-1 7510-A2-GB20-10 November 1997 Configuration Option T ables A Overview The tables in this appendix summarize the configuration options accessed when you select Configuration on the Main Menu. The configuration options are arranged into groups based upon functionality .
Configuration Option T ables A-2 7510-A2-GB20-10 November 1997 System Options Menu For System Options, refer to T able A-1. T o access the System Options screen, follow this menu selection sequence: Main Menu → Configuration (Load Configuration From) → Configuration Edit/Display → System T able A-1.
Configuration Option T ables A-3 7510-A2-GB20-10 November 1997 T able A-1. System Options (2 of 2) LADS Line Rate (Kbps) Possible Settings: 56, 64 Default Setting: 64 Line operating rate for LADS operation. LADS Line Rate (Kbps) option appears when Operating Mode is set to LADS.
Configuration Option T ables A-4 7510-A2-GB20-10 November 1997 Network Interface Options Menu For Network Interface Options, refer to T able A-2. T o access the Network Interface Options screen, follow this menu selection sequence: Main Menu → Configuration (Load Configuration From) → Configuration Edit/Display → Network T able A-2.
Configuration Option T ables A-5 7510-A2-GB20-10 November 1997 Data Port Options Menu For Data Port Options, refer to T able A-3. T o access the Data Port Options screen, follow this menu selection sequence: Main Menu → Configuration (Load Configuration From) → Configuration Edit/Display → Data Port T able A-3.
Configuration Option T ables A-6 7510-A2-GB20-10 November 1997 T able A-3. Data Port Options (2 of 3) Carrier Control by RTS Possible Settings: Constant , Switched Default Setting: Constant Simulates Constant or Switched Carrier operation. Constant – The internal RTS is forced on and the DSU is in a constant Data Mode on the transmit line.
Configuration Option T ables A-7 7510-A2-GB20-10 November 1997 T able A-3. Data Port Options (3 of 3) Monitor DTR Possible Settings: Enable , Disable Default Setting: Enable Indicates to the DSU whether to monitor the Interchange Circuit CT108, Data T erminal Ready (DTR), from the DTE.
Configuration Option T ables A-8 7510-A2-GB20-10 November 1997 T able A-4. T erminal Port Options (2 of 2) Disconnect Time(minutes) Possible Settings: range 1 – 60 Default Setting: 5 Number of minutes of inactivity before the A TI session terminates automatically .
B-1 7510-A2-GB20-10 November 1997 W orksheets B Overview The worksheets in this appendix summarize the configuration options accessed when you select Configuration on the Main Menu. The possible menu selections are displayed with the default settings and the possible settings.
Worksheets B-2 7510-A2-GB20-10 November 1997 Network Interface Configuration Option Settings Default in [ Bold ] Network-initiated DSU Loopback (64K CC) [ Enable ], Disable Data Scrambling (64K CC) Enable, [ Disable ] V .
C-1 7510-A2-GB20-10 November 1997 Cables and Pin Assignments C Overview The following sections provide pin assignments for the: T erminal Port EIA-232 Connector V .
Cables and Pin Assignments C-2 7510-A2-GB20-10 November 1997 T erminal Port EIA-232 Connector The T erminal port connects to a PC or VT100-compatible terminal.
Cables and Pin Assignments C-3 7510-A2-GB20-10 November 1997 V .35 User Data Port Connector The following table provides the pin assignments for the 34-position V .
Cables and Pin Assignments C-4 7510-A2-GB20-10 November 1997 Standard EIA-232-D Cr ossover Cable A standard crossover cable can be used to connect the T erminal port to an external modem.
Cables and Pin Assignments C-5 7510-A2-GB20-10 November 1997 LAN Adapter Converter and Cable The following figure shows the pin assignments for the: DB25 plug to modular jack converter between the.
D-1 7510-A2-GB20-10 November 1997 T echnical Specifications D T able D-1. Model 7510 DSU T echnical Specifications (1 of 2) Item Specifications Housing Height (including feet) Height (without feet) Width Depth (case) Depth (case and connectors) 2.1 inches (5.
T echnical Specifications D-2 7510-A2-GB20-10 November 1997 T able D-1. Model 7510 DSU T echnical Specifications (2 of 2) Item Specifications Network Interface Data rates LADS data rates Services supported 56 kbps and 64 kbps clear channel (CC) 56 kbps and 64 kbps 4-wire service Network Compatibility ANSI T1.
GL-1 7510-A2-GB20-10 November 1997 Glossary A single bit stream that combines two or more bit streams. American Standard Code for Information Interchange. A 7-bit code that establishes compatibility between data services. ASCII is the standard for data transmission over telephone lines.
Glossary GL-2 7510-A2-GB20-10 November 1997 Data Mode Idle. Refers to a sequence of ones transmitted or received on the DDS network. Data Set Ready . An EIA-lead standard for V .24 circuit CT 107; an output signal (DCE-to-DTE). Data Service Unit. Data communications equipment that provides an interface between the DTE and the digital network.
Glossary GL-3 7510-A2-GB20-10 November 1997 A method for interleaving several access channels onto a single circuit for transmission over the network. A connection or switching point on the network. A non-latching loopback can only be initiated or terminated by the 56 kbps network service provider .
IN-1 7510-A2-GB20-10 November 1997 Index Numbers 51 1 test pattern, 5-6– 5-7 A alarm condition, 4-1 LED, 4-9 ASCII, printable characters, 3-1 AT I Configuration menu, 3-3 Control menu, 3-1, 6-4 exit.
Index IN-2 7510-A2-GB20-10 November 1997 H hardware revision number , 6-4 health and status, messages, 4-3– 4-4 I identity , 6-4 device name, 3-1 interface connections, 1-4 network status, 4-6 K key.
Index IN-3 7510-A2-GB20-10 November 1997 R rear panel, connections, 1-4 reset device, 6-4 revision numbers, 6-4 RJ48S network interface cable, C-5 RTS, request to send LED, 4-1 1 RXD, received data LED, 4-1 1 S safety instructions.
An important point after buying a device Paradyne 7510 DSU (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Paradyne 7510 DSU yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Paradyne 7510 DSU - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Paradyne 7510 DSU you will learn all the available features of the product, as well as information on its operation. The information that you get Paradyne 7510 DSU will certainly help you make a decision on the purchase.
If you already are a holder of Paradyne 7510 DSU, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Paradyne 7510 DSU.
However, one of the most important roles played by the user manual is to help in solving problems with Paradyne 7510 DSU. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Paradyne 7510 DSU along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center