Instruction/ maintenance manual of the product PS-M01 Oregon Scientific
Go to page of 25
EN Full Weather Station with Radio Controlled Clock (Model #: PS-M01 / PS-M01U) User Manual PS M01 English Cover R7 op 7/24/03, 10:42 AM 1 Black.
EN 1 TABLE OF CONTENTS About this guide ........................................................ 2 Product overview ....................................................... 3 Getting started .......................................................... 8 Batteries .
EN 2 In this box, you will find: • Main unit • Remote sensor • Batteries • AC/DC power adapter ABOUT THIS GUIDE Congratulations on your selection of the Philippe Starck with Oregon Scientific Full Weather Station with Radio- Controlled Clock (PS-M01 / PS-M01U).
EN 3 DESCRIPTIONS 1. Snooze / Light button 2. Light sensor PRODUCT OVERVIEW TOP VIEW 2 1 PS M01 English R17 op 7/24/03, 10:57 AM 3 Black.
EN 4 DESCRIPTIONS 1. Low battery icon 2. Clock 3. Barometer 4. Weather forecast 5. Moon phase 6. Calendar 7. Temperature and humidity 8. Alarm LCD DISPLAY 1 2 3 4 5 6 7 8 PS M01 English R17 op 7/24/03.
EN 5 BUTTON DESCRIPTIONS 1. Select - switch modes / change settings 2. Up - increase setting / activate auto-synch 3. Down - decrease setting / deactivate auto-synch 4.
EN 6 2 BOTTOM AND SIDE VIEW DESCRIPTIONS 1. Battery compartment 2. Backlight switch 3. Reset button 4. Light sensitvity knob 5. DC Power input jack AC power adapter not shown.
EN 7 DESCRIPTIONS 1. Temperature / Trend display 2. Low battery icon 3. Humidity / Trend / Comfort Level display 4. ° C/ ° F switch 5. Channel switch 6.
EN 8 Insert the batteries in the remote unit before you set up the main unit. Do not use rechargeable batteries. AC POWER ADAPTER An AC power adapter is supplied for use with the main unit. You must connect the power adapter if you wish to use the continuous backlight feature.
EN 9 CHANGE SETTINGS Press and hold SELECT for 2 seconds. Then, press UP or DOWN to change each setting. Press SELECT to switch options. REMOTE UNIT SET UP Up to 3 remote units can be used with this product to monitor outdoor temperature and humidity.
EN 10 CLOCK This product can automatically synchronize the date and time with official time-keeping organizations in Frankfurt, Germany (PS-M01) or Rugby, England (PS-M01U). When the unit is within 1500 km (932 miles) of a RF signal, the reception icon will blink during reception.
EN 11 SET ALARM 1. Press SELECT several times until the Alarm area flashes. 2. Press and hold SELECT for 2 seconds to enter the setting mode. 3. Select the hour, minute, melody (1 - 7) and volume level (Lo or Hi). Press UP or DOWN to change the setting.
EN 12 TO TURN THE ALARM OFF OR ON Press any button to stop the alarm. To turn the alarm off completely (deactivate it for the next day), press ALARM . CALENDAR SET DATE Clock auto-synchronization must be deactivated before you manually set the date. ( 10) 1.
EN 13 VIEW THE LAST 24 HOURS Press SELECT 2 times until the Barometer Area flashes. Then, press UP or DOWN to view the last 24 hours history. BAROMETER This product tracks barometric pressure changes over the past 24 hours to provide the weather forecast ( 14) and a trend line showing the direction of barometric change.
EN 14 SET UNIT AND ALTITUDE You can set the unit of measurement (mb/hPa or inHg) and altitude. Setting the altitude allows the product to take more accurate barometric measurements. 1. Press SELECT 2 times until the Barometer Area flashes. 2. Press and hold SELECT for 2 seconds.
EN 15 Outdoor measurements are collected by the remote unit. Temperature is give at the top; humidity is below. VIEW MIN / MAX / CURRENT MEASUREMENTS Press SELECT 3 times until the Temperature and Humidity Areas flash. Press UP or DOWN to scan the readings.
EN 16 Signals from household electrical appliances such as doorbells and home security systems can cause temporary reception failures between the indoor and outdoor units. This is normal and does not affect the general performance of the product. Reception will automatically resume once the interference ends.
EN 17 TRENDS The trend arrow for the last 30 minutes always displays. Indoor and outdoor temperature and humidity trends are shown separately. SET UNIT While in Temperature / Humidity Mode, press SELECT for 2 seconds. Press UP or DOWN to switch between ° C and ° F.
EN 18 2. Move it to the “AUTO” position to enable continuous backlight controlled by light intensity. When activated, the backlight will be on whenever the unit perceives that the room is dark. 3. The Light sensitivity knob is located in the battery compartment.
EN 19 WARNINGS This product is designed to give you years of service if handled properly. Observe the following guidelines: • Never immerse the unit in water. This can cause electrical shock and damage the unit. • Do not subject the main unit to extreme force, shock, or fluctuations in temperature or humidity.
EN 20 Problem Symptom Remedy Temp Shows “LLL” or “HHH” Temperature is out-of- range. Calendar Strange date / month Change language ( 12) Backlight No continuous backlight Plug in AC power adapter. Check the BACKLIGHT switch. ( 8, 17) TROUBLESHOOTING Check here before contacting our customer service department.
EN 21 SPECIFICATIONS Main unit dimensions L x W x H 129 x 43 x 133.3 mm (5.1 x 1.7 x 5.2 inches) Weight 457 grams with batteries Remote unit dimensions L x W x H 75 x 35 x 78.
EN 22 Resolution 0.1 ° C (0.2 ° F) Comfort 20 ° C to 25 ° C (68 ° F to 77 ° F) (see also, Relative humidity) Memory Minimum / maximum Trend + /- 0.
EN 23 Channel No. 1, 2, or 3 Unit ° C or ° F Radio-controlled clock Synchronization Auto or disabled Clock display HH:MM:SS Hour format 12hr AM/PM (MSF format) 24hr (DCF format) Calendar DD/MMM; wee.
EN 24 Additional information: The product is therefore conform with the Low Voltage Directive 73/23/EC, the EMC Directive 89/336/EC and R&TTE Directive 1999/5/EC (appendix II) and carries the respective CE marking.
An important point after buying a device Oregon Scientific PS-M01 (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Oregon Scientific PS-M01 yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Oregon Scientific PS-M01 - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Oregon Scientific PS-M01 you will learn all the available features of the product, as well as information on its operation. The information that you get Oregon Scientific PS-M01 will certainly help you make a decision on the purchase.
If you already are a holder of Oregon Scientific PS-M01, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Oregon Scientific PS-M01.
However, one of the most important roles played by the user manual is to help in solving problems with Oregon Scientific PS-M01. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Oregon Scientific PS-M01 along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center