Instruction/ maintenance manual of the product NE U07 Omron
Go to page of 9
NE U07 Inhalationsgerät – Nebuliser Instruction manual Page 2 Gebrauchsanweisung Seite 20 Mode d’emploi Page 38 Istruzioni per l’uso Pagina 56 Instrucciones de uso Página 74 NE U07 5.
2 3 English General Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3 Components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4 Safety precautions . . . . . . . . . . . . . . . . . . . .
4 5 English Components of the OMRON NE U07 main unit 1 Mouthpiece 2 Aerosol rate adjust knob 3 Cover 4 Casing 5 Nebuliser lamp 6 Battery discharge lamp (only if rechargeable batteries are used) 7 Powe.
6 7 English Safety Precautions Please read the following instructions carefully , as they contain important information concer ning the setting up, use and maintenance of your new nebuliser. • Keep this manual for future reference. • As soon as you have unpacked the nebuliser, check it for visible damage or defects.
9 English 8 Never submerge or wet the AC power unit or cord. Doing so could result in electrical shock. Never operate the unit with the water tank empty . Use only water in the tank. Solutions other than water may cause da- mage to the transducer. Change the water in the water tank after each use.
10 11 English Aerosol output is adjustable by rotating the delivery rate adjust knob placed on the cover. Rotate the knob counterclockwise to increase the rate, or clockwise to reduce the rate. Adjust it to your requirements. Sit relaxed at a table and breathe in the aerosol delivered through the mouthpiece or air tube (optional part).
12 13 English Remove the nebuliser guide, mouthpiece and aerosol volume adjust knob from the cover. • How to remove the delivery rate volume adjust knob: Rotate the knob counterclockwise, adjust the " " mark with the matching mark " " of the cover and pull it upwards.
14 15 English Operation button lamp (AC) does not light up. • With AC adaptor in use. No nebulisation Low nebulisation rate Symptom Correctly insert it. Correctly mount it. Fill water up to proper level. Fill the medication cup and switch on the power by pressing OFF/ON () .
16 Use only OMRON spare parts. The medication cup, mouthpiece and air filter will deteriorate with time. They must be changed from time to time. Medication cup (5 pcs.
An important point after buying a device Omron NE U07 (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Omron NE U07 yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Omron NE U07 - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Omron NE U07 you will learn all the available features of the product, as well as information on its operation. The information that you get Omron NE U07 will certainly help you make a decision on the purchase.
If you already are a holder of Omron NE U07, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Omron NE U07.
However, one of the most important roles played by the user manual is to help in solving problems with Omron NE U07. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Omron NE U07 along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center