Instruction/ maintenance manual of the product RX3 Omron Healthcare
Go to page of 19
1 RX3 Plus English The OMRON RX3 Plus measures your blood pr essure and pulse simply and quickly from the wrist, without the use of an inflation bulb or stethoscope. The measur ement values are stor ed in the memory of the OMRON RX3 Plus. The OMRON RX3 Plus fits wrist circumfer ences from 13.
Instruction manual page 1 RX3 Plus Digital Automatic Blood Pressure Monitor 24031904 RX3 Plus Cover 3/22/04 10:17 AM Pagina 1.
2 RX3 Plus English T able of contents 1 How to obtain meaningful blood pressur e readings 3 2 Overview 4 3 Preparation 5 3.1 Insert batteries 5 3.2 Fit wrist cuff 6 4 Operation 7 4.1 Control functions 7 4.2 Set date and time 8 4.3 Measurement 9 4.4 Read display 10 5 Memory 11 5.
3 RX3 Plus English General • The OMRON RX3 Plus is not suitable for measuring the frequency of cardiac pacemakers. • Consult your doctor during pregnancy , arrhythmia and arteriosclerosis. • Avoid eating, drinking (alcohol), smoking, sport and taking a bath befor e measurement.
4 RX3 Plus English 2 Overview A Display B W rist Cuf f C Set button D Adjust button E Memory button F On/of f button G Battery Compartment A F E D G C B 24031904 RX3 Plus GB 1-18 3/25/04 12:32 PM Pagi.
5 RX3 Plus English 3 Preparation 1 Open the battery compartment. 2 Insert two batteries in the battery compartment. Caution ! Use two identical 1.5V alkaline batteries type AAA! 3 Close the battery compartment.
6 RX3 Plus English 3.2 Fit wrist cuff Caution ! Do not press on/of f button when the wrist cuff is not wrapped around the wrist! S Y S mmH g D I Am m H g P UL S E / m i n M A D JU S T S E T DATE/ TI M.
7 RX3 Plus English SYSmmHg DIAmm Hg P ULSE/min M ADJUST S ET DA TE/TIME SET C D E F H K J P L Q M N T R S 4 Operation C Set button D Adjust button E Memory button F On/of f button H Date. J Systolic blood pr essur e in mmHg. K Diastolic blood pressur e in mmHg.
8 RX3 Plus English 3 Press set button to pr oceed to month setting. Press adjust button to set the current month. 4 Press set button to pr oceed to day setting.
9 RX3 Plus English 5 Press set button to pr oceed to hour setting. Press adjust button to set the current hour . 6 Press set button to pr oceed to minute setting and press adjust button to set the current minutes.
10 RX3 Plus English SYSmmHg DIAmm Hg P ULSE/min M ADJUST S ET DA TE/TIME SET 2 Press on/of f button to start measurement. The OMRON RX3 Plus measures during inflation! Caution ! Sit still, do not move, do not speak and do not touch the OMRON RX3 Plus! 4.
11 RX3 Plus English 5 Memory L M SYSmmHg DIAmm Hg P ULSE/min M ADJUST S ET DA TE/TIME SET S YSmmHg DIAmm Hg PULSE/min M ADJUST S ET DA TE/TIME SET 5.1 Recall average value H/Q Date/time of measur ement. 1 Press memory button for latest and pr evious values.
12 RX3 Plus English 1 Press memory button to turn on power . 2 Press memory button and simultaneously on/off button to erase memory . Caution ! All stored values will be erased! P ress on/of f button to turn off power . SYSmmHg D IA mmHg P ULSE/min M ADJUST S ET DA TE/TIME SET SYSmmHg DIAmm Hg P ULSE/min M ADJUST S ET DATE/TIME SET 5.
13 RX3 Plus English 6 Storage Display empty Fault Cause Rectification Correct r eading not possible Movement, sound vibration, weak pulse W ait for at least thr ee minutes to repeat measurement Low voltage Batteries weak/exhausted Fit two new identical 1.
14 RX3 Plus English 8 Maintenance and spare parts Cleaning instruction • Use a soft, slightly moistened cloth to clean the OMRON RX3 Plus and the wrist cuff. Caution ! Do not use petrol, thinners or similar solvents! Caution ! Do not wash the wrist cuff! • Do not carry out repairs of any kind yourself.
15 RX3 Plus English Product name OMRON Digital Blood Pressure Monitor Model RX3 Plus Display Digital LCD Measurement range Pressure: 0 - 299 mmHg / Pulse: 40 - 180 /minute Accurac y Pressure: ± 3 mmH.
16 RX3 Plus English Blood circulation The blood circulation is r esponsible for supplying the body with oxygen. Blood pressur e is the pressur e exerted on the arteries. The systolic blood pressur e value (higher pressur e or top value)repr esents the blood pressur e produced by contraction of the heart muscle.
17 RX3 Plus English Hypertension accelerates arterial sclerosis which can lead to very serious conditions such as stroke and myocar dial infarction. For these r easons it is very important to know whether the blood pressur e is within a healthy range.
T reatment of high blood pr essure If your blood pr essur e reaches upper values of 140 - 160 mmHg and lower values of 90 - 95 mmHg in repeated measur ements over several days, you should consult your doctor for detailed medical examination.
An important point after buying a device Omron Healthcare RX3 (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Omron Healthcare RX3 yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Omron Healthcare RX3 - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Omron Healthcare RX3 you will learn all the available features of the product, as well as information on its operation. The information that you get Omron Healthcare RX3 will certainly help you make a decision on the purchase.
If you already are a holder of Omron Healthcare RX3, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Omron Healthcare RX3.
However, one of the most important roles played by the user manual is to help in solving problems with Omron Healthcare RX3. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Omron Healthcare RX3 along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center