10 series Blood Pressur e Monitor with C omF it TM Cuff Model BP785 INSTRUCTION MANU AL ESP AÑOL ENGLISH.
2 Befor e Using the Monitor Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4 Safety Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5 Operating the Device .
T aking a Measurement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .28 Calibration Check System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .28 Cuff Wrap Guide . . . . . . . . . . . . . . . . . . . . . . .
4 Thank you for purchasing the Omron ® BP785 IntelliSense ® Automatic Blood Pressure Monitor with ComFit TM Cuff. INTRODUCTION Fill in for future referenc e. DA TE PURCHASED: __________________ SERIAL NUMBER: ____________________ Y our ne w digital blood pressure monitor uses the oscillometric method of blood pressure measurement.
5 T o assure the corr ect use of the pr oduct basic safety measures should always be followed including the warnings and cautions listed in this instruction manual. W ARNING Indicates a potentially hazardous situation which, if not av oided, could result in death or serious injury .
OPERA TING THE DEVICE (continued) This device is intended for use in measuring blood pressure and pulse rate in the adult population. Do not use this device on inf ants or persons who cannot express their intentions. Read the Special Conditions section (page 34) of the instruction manual if your systolic pressure is known to be more than 220 mmHg.
RISK OF ELECTRICAL SHOCK Do not plug or unplug the power cord into the electrical outlet with wet hands. Do not ov erload power outlets. Plug the de vice into the appropriate voltage outlet. CARE AND MAINTENANCE Do not subject the monitor to strong shocks, such as dropping the unit on the floor .
8 BEFORE T AKING A MEASUREMENT T o ensure a reliable reading follow these recommendations: 1. A void eating, drinking alcohol, smoking, e xercising, and bathing for 30 minutes prior to taking a measurement. Rest for at least 15 minutes prior to taking the measurement.
9 KNOW Y OUR UNIT Main Unit: Air Jack Battery Compar tment Start/Stop Button USER ID Selection Switch Morning/Evening A verage ( ) Button Memor y ( ) Button Display AC Adapt er Jack Operating Instruct.
KNOW Y OUR UNIT 10 Componen ts: Arm Cuff Air T ube Air Plug (Connects to Air Jack) AC A dapter Storage Case Housing Cord Quick Start Guide Instruction Manual.
11 UNIT DISPLA Y Diastolic Blood Pressure Systolic Blood Pr essure Movement Symbol Pulse Display / Memory Number Date/Time Display Low Battery Indicator Deflation Symbol Morning Av erage Symbol Heartb.
12 IRREGULAR HEAR TBEA T SYMBOL ( ) When the monitor detects an irregular rhythm two or more times during the measurement, the Irregular Heartbeat Symbol ( ) will appear on the display with the measurement values.
The American Heart Association 1 recommends the following guideline for upper limit of normal for home blood pressure readings: AHA Home Guideline for Upper Limit of Normal BP Systolic Blood Pressure 135 mmHg Diastolic Blood Pressure 85 mmHg This is a general guideline because blood pressure depends on age and morbidity .
HEAR TBEA T SYMBOL ( ) T AKING A MEASUREMENT The Heartbeat Symbol flashes on the display during the measurement. The Heartbeat Symbol flashes at e very heartbeat. A VERA GE V ALUE SYMBOL ( ) The A verage V alue Symbol is displayed when you press the memory button.
IMPORT ANT SAFET Y INSTRUCTIONS SA VE THESE INSTRUCTIONS NO TES: • Use only the authorized Omron A C Adapter that came with this monitor . • W e recommend you install the batteries ev en if the A C Adapter is used. If no batteries are installed, you may need to reset the date and time if the A C Adapter is disconnected.
TO CONNECT THE A C AD APTER ① Insert the A C Adapter Plug into the A C Adapter Jack on the back side of the monitor as illustrated. ② Plug the A C Adapter into a 120V A C outlet (60 cycles). TO DISCONNECT THE A C ADAPTER ① Hold the Housing to remov e the A C Adapter from the electrical outlet.
1. Remov e the battery cover with pulling the hook up while pushing it in the direction of the arrow . 2. Install 4 “ AA” size batteries so the + (positiv e) and - (negativ e) polarities match the polarities of the battery compartment as indicated.
B A TTERY REPLA CEMENT When the Low Battery Indicator appears on the display screen turn the monitor off and remo ve all the batteries. Replace with four new batteries at the same time. Longlife alkaline batteries are recommended. CAUTION If battery fluid should get in your eyes, immediately rinse with plenty of clean water .
19 Set the monitor to the current date and time before taking a measurement for the first time. If the date and time are not set correctly , the measurement values stored in the memory and the a verage values may not be correct. If the date and time are not set, “-:--” appears during or after measurement.
1. SETTING THE TR UREAD TM MODE 1) Select your USER ID (A or B). 2) Press the SET button. The T ruRead TM symbol and the oFF setting appears on the display . 3) Press the Up or Down b utton ( / ) to select on. NO TE: Press the Up or Down button to alternate between on and oFF .
4) Press the SET button to conf irm the change. If on is selected, the number of seconds between each measurement is displayed. NO TE: The default v alue between each measurement is 60 seconds. 5) Press the Up or Down ( / ) to change the interval of time between each measurement.
22 SET TING THE DA TE/TIME AND TRUREAD TM 2. SETTING THE YEAR The year can be set between 2010 and 2040. When the display reaches 2040, it will return to 2010. Press the Up button ( ) to advance by increments of one year . Press the SET button to set the current year .
23 4. SETTING THE D A Y Press the Up button ( ) to advance by increments of one day . Press the SET button to set the current day . The hour flashes on the display . 5. SETTING THE HOUR The time is set using AM or PM. Press the Up button ( ) to advance by increments of one hour .
CAUTION Read all of the information in the instruction manual and any other literature in the box before operating the unit. CAUTION This device is intended for use in measuring blood pressure and pulse rate in the adult population. Do not use this device on inf ants or persons who cannot express their intentions.
25 3. Sit on a chair with your feet flat on the floor . Place your left arm on a table so the cuff is le vel with your heart. 4. Hold the thumb grip on the cuff securely with your right hand.
26 6. Apply the cuff to your left upper arm so the blue stripe is on the inside of your arm and aligned with your middle finger . The air tube runs down the inside of your arm. The bottom of the cuff should be approximately 1/2" abov e your elbow .
APPL YING THE CUFF ON THE RIGHT ARM When taking a measurement using the right arm use this instruction for Step 6 on page 26. Apply the cuff to your right upper arm so the thumb grip is centered on the inside of your inner arm. The bottom of the cuf f should be approximately 1/2'' abov e your elbow .
The monitor is designed to take measurements and store the measurement values in the memory for tw o people using USER ID A and USER ID B. The monitor can also be used to take a single measurement for other persons using the GUEST Mode. The USER ID symbol is not displayed when using the GUEST Mode.
USING THE GUEST MODE 1. Press and hold the ST AR T/STOP button. The A and B Symbols disappear from the display . 2. Release the ST AR T/STOP button. The cuff starts to inflate automatically . NO TE: T o stop the inflation press the ST AR T/STOP b utton.
SELECTING THE USER ID Select your USER ID. Always use the same USER ID when taking a measurement. The monitor stores the measurement v alues in the memory by the USER ID selected. These measurement v alues are used to calculate the Morning A verages and Ev ening A verages.
USING THE SINGLE MODE 1. Select your USER ID (A or B). 2. Press the ST AR T/STOP button. All symbols appear on the display . The USER ID Symbol you selected flashes on the display . The cuff starts to inflate automatically . As the cuff inflates, the monitor automatically determines your ideal inflation lev el.
3. Inflation stops automatically and the measurement is started. As the cuff deflates, decreasing numbers appear on the display . The Heartbeat Symbol ( ) flashes at every heartbeat. 4. When the measurement is complete, the arm cuff completely deflates.
USING THE TR UREAD TM MODE 1. Select your USER ID (A or B). 2. Press the ST AR T/STOP button. All symbols appear on the display . The USER ID Symbol you selected flashes on the display . The cuf f starts to inflate automatically . NO TE: T o stop the inflation or measurement, press the ST AR T/STOP button.
T AKING A MEASUREMENT 34 The second measurement is complete, waiting to start the next measurement. The consecutiv e measurements are complete. The av erage for three measurements appears on the display . 5. Press the SET button to display the blood pressure and pulse rate for the first measurement.
T AKING A MEASUREMENT 35 If your systolic pressure is known to be more than 220 mmHg, press and hold the ST AR T/STOP button until the monitor inflates 30 to 40 mmHg higher than your expected systolic pressure. NO TES: • Do not apply more pressure than necessary .
The monitor is designed to store the blood pressure and the pulse rate in the memory for two people (USER A and USER B) ev ery time a measurement is completed. The monitor automatically stores up to 100 sets of measurement values (blood pressure and pulse rate) for each user (A and B).
TO DISPLA Y THE MEASUREMENT V ALUES 1. Select your USER ID (A or B). 2. Press the Memory button ( ). The A verage Symbol ( ) appears on the display when the a verage reading is shown.
3. Press the Down b utton ( ) to display the most recent set of measurement values on the screen. The values are displayed from the most recent to the oldest. NO TE: The date and time are alternately displayed with the measurement values. Press the Up or Down b utton to display the next set of v alues.
MORNING AND EVENING A VERA GES The monitor calculates and displays a weekly av erage for measurements taken in the morning ( ) and evening ( ). The monitor stores 8 weeks of Morning A verages and 8 weeks of Ev ening A verages for each user (A and B).
TO DISPLA Y MORNING AND EVENING A VERA GES 1. Select your USER ID (A or B). 2. Press the Morning/ Evening A verage b utton ( ) to select the Morning or Evening a verage. The av erage for the current week “THIS WEEK” appears on the display . 3. Press the Down ( ) button to display the pre vious weeks.
41 USING THE MEMORY FUNCTION DISPLA Y COMBIN A TIONS In addition to the Morning A verage and Ev ening A verage Symbols, the monitor may also display the Morning Hypertension Symbol if the morning av erage for that week is abov e the AHA guidelines. (See page 13 for details.
42 The Morning Hypertension Symbol () appears if the weekly av erage for morning measurements is abov e 135/85. In this case the Morning Hypertension Symbol () is displayed when the Evening A verage is displayed, regardless of the v alues for the Evening A verage.
43 T o keep your digital blood pr essure monitor in the best condition and pr otect the unit from dam age, follow the dir ections listed below: Keep the monitor in the storage case when not in use. Make sure the A C adapter is placed under the main unit so that it does not damage the display .
Use the unit consistent with the instruction pro vided in this manual. CAUTION Changes or modification not appro ved by Omron Healthcare will void the user w arranty . Do not disassemble or attempt to repair the unit or components. CAUTION Use only Omron authorized parts and accessories.
Contact Customer Service for repair information. Sensor may be out of alignment. Refer to “ Applying the Arm Cuf f”. Cuff is not applied correctly . Air plug disconnected. Insert the plug securely . Refer to “ Applying the Arm Cuff”. Arm cuff not applied correctly .
46 ERROR INDICA TORS AND TROUBLESHOO TING TIPS PROBLEM CA USES AND SOLUTIONS No power . No display appears on the unit. Replace all four batteries with new ones. Check the battery installation for proper placement of the battery polarities. Measurement values appear too high or too low .
47 FC C ST A TEMENT NO TE: PO TENTIAL FOR RADIO/TELEVISION INTERFERENCE (for U.S.A. only) This product has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.
LIMITED W ARR ANTIES 48 Y our Omron ® BP785 IntelliSense ® Automatic Blood Pressure Monitor, excluding the arm cuff, is w arranted to be free from defects in materials and workmanship appearing within 5 years from the date of purchase, when used in accordance with the instructions provided with the monitor .
49 Model: BP785 (HEM-7222-Z) Display: LCD Digital Display Measurement Range: Pressure: 0 to 299 mmHg, Pulse: 40 to 180/min. Accuracy/Calibration: Pressure: ±3mmHg or 2% of reading Pulse: ±5% of read.
Manufactured by OMR ON HEAL THCARE Co., Ltd. Made in China Distributed by: Omron Healthcar e, Inc. 1200 Lakeside Dri ve Bannockburn, IL 60015 www .omronhealthcare.
An important point after buying a device Omron Healthcare BP785 (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Omron Healthcare BP785 yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Omron Healthcare BP785 - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Omron Healthcare BP785 you will learn all the available features of the product, as well as information on its operation. The information that you get Omron Healthcare BP785 will certainly help you make a decision on the purchase.
If you already are a holder of Omron Healthcare BP785, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Omron Healthcare BP785.
However, one of the most important roles played by the user manual is to help in solving problems with Omron Healthcare BP785. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Omron Healthcare BP785 along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center