Instruction/ maintenance manual of the product AP200 Asus
Go to page of 32
® A P200 Dual Pentium ® III Group Server Hardware Reference Guide.
AP200 Hardware Refer ence Guide 2 User ’ s Notice No part of this manual, including the products and software described in it, may be reproduced, transmitted, transcribed, stored in a retrieval syst.
AP200 Hardware Refer ence Guide 3 ASUS Contact Information ASUST eK COMPUTER INC. (Asia-Pacific) Marketing Address: 150 Li-T e Road, Peitou, T aipei, T aiwan 1 12 T elephone: +886-2-2894-3447 Fax: +886-2-2894-3449 Email: info@asus.
AP200 Hardware Refer ence Guide 4 Contents I. Introduction 1-1. Sections ........................................................................... 7 1-2. Component Checklist ....................................................... 7 1-3. Features ...
AP200 Hardware Refer ence Guide 5 Contents 4-2. Motherboard ................................................................... 19 Motherboard Screws ......................................................... 19 Chassis Intrusion Photo Sensor .........
AP200 Hardware Refer ence Guide 6 FCC & DOC Compliance Federal Communications Commission Statement This device complies with FCC Rules Part 15. Operation is subject to the following two conditions.
7 I. Introduction AP200 Hardware Refer ence Guide I. Introduction The AP200 Hardware Reference Guide provides information and proce- dures on the various components used in this server . This guide is intended for experienced users and integrators with hardware knowledge of personal computers.
8 I. Introduction AP200 Hardwar e Refer ence Guide I. Introduction Features 1-3. Features The AP200 is a group server configured on the ASUS P2B-DS/P2B-D smart motherboard which uses the 440BX chipset from Intel and supports two Pentium III/II processors and 100MHz front side bus in order to handle any complicated task.
9 I. Introduction AP200 Hardware Refer ence Guide I. Introduction 1-4. Safeguards Observe the following safety instructions any time you are connecting or disconnecting any devices. Operation Safety T ools Required A Phillips (cross) screwdriver and a standard (flat) screwdriver are needed to install or remove the components in this server .
10 I. Introduction AP200 Hardwar e Refer ence Guide I. Introduction Electrical Safety IMPOR T ANT • Before installing or removing signal cables, ensure that the power cables for the system unit and all attached devices are unplugged.
11 I. Introduction AP200 Hardware Refer ence Guide I. Introduction 1-5. Preparation 1. Unpack your server , but do not connect the power cord. Preparation 2. Unlock the padlock if one is used. This server is equipped with a lock- able panel to prevent unauthorized access.
12 II. Components AP200 Hardwar e Refer ence Guide II. Components 2-1. System Overview Front V iew A B C D F E I J H G A. T op Panel B. LED Status Indicator C. CD-ROM Drive D. 5.25” Device Bays E. A TX Power Button F . Floppy Disk Drive G. Reset Button H.
13 II. Components AP200 Hardware Refer ence Guide II. Components Rear V iew A B C D E F G H I J K L M N O P A. T op Panel Screw B. Air Outlet V ents C. Power Supply Fan D. Power Supply Switch E. V oltage Selection F . AC Power In Connector G. PS/2 Keyboard H.
14 II. Components AP200 Hardwar e Refer ence Guide II. Components Side View A B C D E F G H I J L M K A. CD-ROM Drive B. 5.25” Device Cage C. Floppy Disk Drive D. 3.5” Device Cage E. Hard Disk Drive F . Fan Module G. Speaker H. Long Card Guide I. Hard Disk Drive Carrier Plate J.
15 II. Components AP200 Hardware Refer ence Guide II. Components Chassis Features 2-2. Chassis Features 5.25” Device Cage The 5.25” device cage is used for mounting three 5.25” devices such as CD- ROM, tape, and hard disk drives. 3.5” Device Cage The 3.
16 III. Getting Started AP200 Hardwar e Refer ence Guide III. Getting Started Startup / LED / BIOS 3-1. Starting the Server T urn on the system unit by turning the power knob clockwise and pushing inwards momentarily .
17 IV . Hardware Setup AP200 Hardware Refer ence Guide IV . HW Setup 4-1. Chassis Removing the Left Panel The left panel needs to be removed to gain access to the internal system. Left Panel Removal Procedur e: 1. Remove the padlock if one is used on the left panel.
18 IV . Hardware Setup AP200 Hardwar e Refer ence Guide IV . HW Setup Chassis Removing the Front & T op Panels Before removing the front panel, the top panel must be unscrewed and re- moved. Lean the front panel over the edge of a table or book. Reach your fingers up into the front panel and pull the front panel away from the chassis.
19 IV . Hardware Setup AP200 Hardware Refer ence Guide IV . HW Setup Motherboard Stabilizing Link Bar The stabilizing link bar needs to be removed in order to access the mother - board or remove the 3.
20 IV . Hardware Setup AP200 Hardwar e Refer ence Guide IV . HW Setup Motherboard Chassis Intrusion Photo Sensor This motherboard has a photo sensor onboard, which detects extreme levels of light entering the chassis such as when the chassis is opened, and sends a signal to the ASMA software in such an event.
21 IV . Hardware Setup AP200 Hardware Refer ence Guide IV . HW Setup 3.5” Device Cage 4-3. 3.5” Device Cage Before hard or floppy disk drives can be installed or removed from the 3.5” device cage, you must remove the device cage from the chassis.
22 IV . Hardware Setup AP200 Hardwar e Refer ence Guide IV . HW Setup Floppy Disk Drive Cable Connections The 1.44MB floppy disk drive requires signal and power connections. Align the red stripes of the signal and power cables so that they face each other .
23 IV . Hardware Setup AP200 Hardware Refer ence Guide IV . HW Setup Hard Disk Drives CD-ROM Drive Mounting and Connections The CD-ROM disk drive mounts only in the 5.25” device cage and requires signal and power connections. The red stripe of the signal and power cables should face each other .
24 IV . Hardware Setup AP200 Hardwar e Refer ence Guide IV . HW Setup Hard Disk Drives Mounting the Hard Drive above the Power Supply Insert the carrier plate and hard disk drive into the slot on the bottom of the chassis top panel.
25 IV . Hardware Setup AP200 Hardware Refer ence Guide IV . HW Setup Air Circulation System External SCSI T erminator In order to prevent SCSI signal loss, the provided external SCSI terminator must be used at the end of the 68-pin SCSI cable. 50-pin SCSI cables may also use terminators but usually use termination jumpers on the device it- self.
26 IV . Hardware Setup AP200 Hardwar e Refer ence Guide IV . HW Setup Card Guide / Speaker 4-7. Long Card Guide T o reach into the inside front of the chassis, you may want to remove the long card guide first. Press the plastic clips with a screwdriver as shown.
27 IV . Hardware Setup AP200 Hardware Refer ence Guide IV . HW Setup Power Supply 4-9. Power Supply Removing the Power Supply Unmounting the power supply must be done from the inside of the chassis. Remove the left panel of the chassis and the four screws securing the power supply .
28 IV . Hardware Setup AP200 Hardwar e Refer ence Guide IV . HW Setup Power Information 4-10. Power Information Output V oltage Regulation Output Min Max T olerance +5.0V +4.75V +5.25V ±5% +12.0V +1 1.40V +12.60V ±5% +3.3V +3.135V +3.465V ±5% -12.0V -1 1.
29 V . Appendix AP200 Hardware Refer ence Guide V . Appendix SCSI Cable Limits i. SCSI Cable Limits SCSI cables have a limit to the length that it may have. Exceeding the length may cause problems mounting or using any one of the SCSI devices. Cable Limits Max Data T ransfer Rates Max Devices 1) 12m (29.
30 V . Appendix AP200 Hardwar e Refer ence Guide V . Appendix SCSI Cabling ii. SCSI Connection Example This is an example of how SCSI devices can be connected to your server . • T wo 9GB Ultra2-SCSI hard disks in the 3.5” cage can be connected to the Ultra2 connector on the motherboard for 18GB of main storage.
31 V . Appendix AP200 Hardware Refer ence Guide V . Appendix ASUS RAID Solutions iii. ® RAID Solutions ASUS PCI-DA2100/2200 Series SCSI RAID Card • PCI-DA2100 series support 4x86 DX4-100 processor .
32 V . Appendix AP200 Hardwar e Refer ence Guide V . Appendix ASUS Barebone Servers iv . ® Barebone Servers Pentium ® III PC100 ECC Ultra2 SCSI 5.25” Pentium ® II Max.
An important point after buying a device Asus AP200 (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Asus AP200 yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Asus AP200 - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Asus AP200 you will learn all the available features of the product, as well as information on its operation. The information that you get Asus AP200 will certainly help you make a decision on the purchase.
If you already are a holder of Asus AP200, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Asus AP200.
However, one of the most important roles played by the user manual is to help in solving problems with Asus AP200. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Asus AP200 along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center