P0881594 Is sue 02 MICS-XC Nors tar-Comp anion Installer G uide Registering individual port ab le s Register ing the C30 60 The following section des cribes the pr ocedures involved in registering C ompanion C3060 po rtable telephones.
90 / Regist er ing indi vi dua l por tables MICS-XC Norsta r-Companion Ins taller Guide P0881594 Is sue 02 Note: Wire less Systems is a registra tion list of names for up to six diff erent systems. If the list is full, and you must add another system, de-register an existing system name.
Regis teri ng in divid ual po r tables / 91 P0881594 Is sue 02 MICS-XC Nors tar-Comp anion Installer G uide • Press the dial pad ke y until the letter you need appears on the displa y. For example, press key 5 three times to display the letter L. • P re ss S S S SP P P PA A A AC C C CE E E E to add a blank s pace to the name.
92 / Regist er ing indi vi dua l por tables MICS-XC Norsta r-Companion Ins taller Guide P0881594 Is sue 02 b . Dial the number of a working telephone. The telephone must ring to conf irm the regis tra ti on.
Regis teri ng in divid ual po r tables / 93 P0881594 Is sue 02 MICS-XC Nors tar-Comp anion Installer G uide If a portable is regist ered on othe r system s, it will still be available on those systems. You deregister one system at a time. Note: If you ar e out of r ange of the system, this procedur e clears registration data only from the portable.
94 / Regist er ing indi vi dua l por tables MICS-XC Norsta r-Companion Ins taller Guide P0881594 Is sue 02 Measuring RS SI for a C306 0 The Receive Signal Strength Indicator (RSSI) is a measurement of the s ignal s trength the B ase Stat ion receives from the portable.
Regis teri ng in divid ual po r tables / 95 P0881594 Is sue 02 MICS-XC Nors tar-Comp anion Installer G uide You can also pres s ⁄ to view the information in “ standard” display mode. This mode displays the radio ID of the Base Station to whic h the por table is li nke d, followed by the signal strength and power mode.
96 / Regist er ing indi vi dua l por tables MICS-XC Norsta r-Companion Ins taller Guide P0881594 Is sue 02 • The five-digit I D of the B ase Station radio you want to measure, by mapping the Bas e Station location to the T CM port. The first four digits indicate t he TCM port to which the Base Station is connec ted.
Regis teri ng in divid ual po r tables / 97 P0881594 Is sue 02 MICS-XC Nors tar-Comp anion Installer G uide You can also pres s ⁄ to view the information in “ standard” display mode. This mode displays the radio ID of the Base Station to whic h the por table is li nke d, followed by the signal strength and power mode.
98 / Regist er ing indi vi dua l por tables MICS-XC Norsta r-Companion Ins taller Guide P0881594 Is sue 02 To register the C30 50 1. Turn on registration for your s ystem. 2. Open the portable flap. The portable displays the current system name or No system selected for two seconds.
Regis teri ng in divid ual po r tables / 99 P0881594 Is sue 02 MICS-XC Nors tar-Comp anion Installer G uide 7. Enter the s ystem name (up to 16 cha racters), for example NORTEL 1 . ( If you ar e registering to only one sys tem, use the portable telephone u ser’s name.
100 / Re gister ing ind ividual por tabl es MICS-XC Norsta r-Companion Ins taller Guide P0881594 Is sue 02 6. Close the portable’s flap, and set the Ringer Control Switch to g . If the portable is twinned with a desk tele phone, make sure the desk te lephone is idle and Call Forw ard is not active.
Regis teri ng ind ividu al por ta bles / 101 P0881594 Is sue 02 MICS-XC Nors tar-Comp anion Installer G uide 2. P re ss Í . The portable displays WI R E LE SS S Y ST E M S and ADD . Note : Do not select AD D . 3. Press the scroll keys ( ” or ’ ) to display the system name that you want to dere gister.
102 / Re gister ing ind ividual por tabl es MICS-XC Norsta r-Companion Ins taller Guide P0881594 Is sue 02 Measuring RS SI for a C305 0 The Receive Signal Strength Indicator (RSSI) is a measurement of the s ignal s trength the B ase Stat ion receives from the portable.
Regis teri ng ind ividu al por ta bles / 103 P0881594 Is sue 02 MICS-XC Nors tar-Comp anion Installer G uide You can also use directed RSSI to prevent hand-off while you find a cell edge. To measure the RSSI of a specifi c radio, you must be in range of two Base Stations—the one you want to measure and another Ba se Station.
104 / Re gister ing ind ividual por tabl es MICS-XC Norsta r-Companion Ins taller Guide P0881594 Is sue 02 5. Enter the five-digit ID code for the Base Station radio you want to measure. T he portable displays this ID followed by the signal s trength and the power mode, for exa mple 03142 - 54 H .
Regis teri ng ind ividu al por ta bles / 105 P0881594 Is sue 02 MICS-XC Nors tar-Comp anion Installer G uide on page 106 to over write the system number then return to step 2 of this pr ocedure. 4. P re ss s , the n pr ess m . The display shows Regis tering.
106 / Re gister ing ind ividual por tabl es MICS-XC Norsta r-Companion Ins taller Guide P0881594 Is sue 02 If t he portable does not ring, try to register the por table again. If you do not hear a dial t one, or if the portable does not ring, refer to the Troubleshooting se ction in this guide.
Regis teri ng ind ividu al por ta bles / 107 P0881594 Is sue 02 MICS-XC Nors tar-Comp anion Installer G uide 6. To continue u sing the por table, press r . Measur ing RS SI for a C3020 (Can ada only) The R e ceive Signal Strength I ndicator (RSSI) is a measurement of the si gnal stre ngth the Base Station receive s from t he portable.
108 / Re gister ing ind ividual por tabl es MICS-XC Norsta r-Companion Ins taller Guide P0881594 Is sue 02 Measuring direct ed RSSI You may want t o measure the Receive S ignal Strengt h Indicator between a portable and a specific Base Station radio. For example, you may suspect that a radio in a Base St at ion is not working pr operly.
Regis teri ng ind ividu al por ta bles / 109 P0881594 Is sue 02 MICS-XC Nors tar-Comp anion Installer G uide Meas uring direct ed RSSI using you r p ortab le 1. Perform an undir ected Receive Signal Strength Indicator by following steps 1 to 3 in “ To measure undirected RS SI’’ on page 102.
110 / Re gister ing ind ividual por tabl es MICS-XC Norsta r-Companion Ins taller Guide P0881594 Is sue 02 For the steps involved in operating a Norstar Companion portable, see the Companion Portable Telephone Use r Guide that is s upplied with the portable.
An important point after buying a device Nortel Networks 03050 (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Nortel Networks 03050 yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Nortel Networks 03050 - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Nortel Networks 03050 you will learn all the available features of the product, as well as information on its operation. The information that you get Nortel Networks 03050 will certainly help you make a decision on the purchase.
If you already are a holder of Nortel Networks 03050, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Nortel Networks 03050.
However, one of the most important roles played by the user manual is to help in solving problems with Nortel Networks 03050. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Nortel Networks 03050 along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center