NLS-HR15Series NLS-HR15XX-3 E Cordless 1D Ba rcode Scanner User Guide.
© 2012 by New land Auto -ID Tech. Co., Ltd. All rig hts reserved. Please ca refully read the manual before use the product, an deffectively to protect the sa fet y o f products operation. Please keep this manual after reading prop erly and save for the next reading.
Table of Contects Preface ............................................................................................................................................................................................................... 1 Introduction ..
SetupProcess Flow ........................................................................................................................................................................ 17 Default Setup ...............................................
Add Custom Prefix or Not .............................................................................................................................................................. 35 Define the Custom Prefix .......................................
Set Whether or not to Read 5-Digit Extracode ........................................................................................................................... 49 Extended Setup ................................................................
Allow to Read Deutsche14 or not ................................................................................................................................................. 62 CodeID Setup .........................................................
Allow to Read Codabar or not ....................................................................................................................................................... 75 CodeID Setup ......................................................
CodeID Setup .................................................................................................................................................................................. 89 Chapter 7 Appendix .....................................
.
1 Preface Introduction This manual provides information about using the NLS-HR15 series1D barcode cordlessscanner:NLS-HR15XX- 3E . (Hereinafter refer to as “HR15 cordless s canner”) Chapter Descriptions Chapter1,Getting Started :Generaldescription of HR15 cordless scanner included ing all the parameters of HR15 cordless scanner.
2 Chapter 1 Getti ng Started Introduction HR15 cordless scanner is a ty pe of 1D barcode scanner with ex cellent performance, except for all the n ormal 1D barcode, it also can read the sta cked 2D barcode such as PDF417 and the MicroPDF17.
3 CD15 Cradle The main parts of CD15 cradle are shown in the following pict ure. Button Definition : P : Batch Transmission M : Pair/Sea rch LED Indicator Definition : Blue : Wireless Networ.
4 Synchronized mode: HR15 w ithin wireless coverage area, barcode data will transfer to the host PC immediately after successful decoded, and fail transfer when out of the coverage area. Asynchronized mode: HR15 within w ireless coverage area, the barcode d ata will be transmitted to the host PC immediately aft er successful decoded.
5 USB USB interface on the host RS232 RS232 interface on the host Please check the port on the host and purchase the right cab le. Using USB C able Connect the CD15 cradle with host PC through USB cable. 1. Plug the RJ45 connector into CD15 communication port.
6 Using RS232 Cable Connecting the CD 15 cradle with host through RS232 cable: 1 Plug the RJ45 connector into HR15 scanner . 2 Plug the RS232 connector into Host. 3 Connect the RS232 cable with power adapter . Power-on, Power-off, Sleep, Reboot Power- on Connect the HR15 with the host, the HR15 will power on automatically (factory default).
7 Reboot If the HR15 no response or abnormal, please pull out the cable from Host PC then plug again to reboot the HR15. Reading Window Maintenance The scanning window should ke ep clean. Avoid hard and rough objects to clean the reading window that will easy to cause the damage or scratch.
8 Reading Depth of Field.
9 Specification Performance Light Source 620nm Visible Red LED Scan Pattern CCD linear image Symbologies Code128, EAN-13, EAN-8, Code39,UPC-A, UPC-E, Codabar, I nterleaved 2 o f 5, ISBN,Code 93, UCC/EAN-128, GS1 Databar, PDF417, MicroPDF417 etc.
10 FCC Part15 Class B, CE EMC Class B, CCC Test condition: Code39 , Data length=3bytes ,M inimum space width= 10mil , W idth r adio=2.5:1 , PCS=0.8, Barcode height=11mm, Testing distance=120mm,Envirmenttemperature =23 ℃ , En vi rment light Illumination = 200 LUX Overview Left View The picture below is the left view of HR15 scanner.
11 CD15Ceadle Previe w Barcode Reading Make sure the scanner, data cable and power are properly connectedbefore turn on the pow er. Pressing the trigger to activate the illumination light, then the red illuminating line will appear.
12.
【 S tart Setup 】 【 Exit Setup 】 13 Chapter 2 Gene ral Configuration Introduction There are two ways to set up the barcode engine. Setting Bar code To u se d reading a series of special barcode to setting the barcode engine.
【 S tart Setup 】 14 【 Exit Setup 】 Use the Setting Barcodes The s etup function will be activ ated by reading the “ Start Setup ” barcode.
【 S tart Setup 】 【 Exit Setup 】 15 Use the Setup Command The setup command is based on t he communication serial port; it is meant to use t he visible charaters from 0x20 to 0x7D to describe all the content.
【 S tart Setup 】 16 【 Exit Setup 】 D390ADC8D38FF5E6D99DAA|E1DFA587}” 8. If the setting command contains pa rameters, then the command will be combined according to the command system definition. For example: The combined c ommand s tring which is sto p b y 0x0D and 0x 0A .
【 S tart Setup 】 【 Exit Setup 】 17 SetupProc ess Flow.
【 S tart Setup 】 18 【 Exit Setup 】 Default Setup Factory Default Setting All th e sc anners h ave the factory d efault setting, by reading the “Restore to Factory Default” barcode, the scanner will restore the factory default.
【 S tart Setup 】 【 Exit Setup 】 19 Power off Timer The HR15 cordless scannerwill power-off automatically if it hibernates overtime (default: 5 minutes) 【 Auto power off after 5 minutes in sleep mode . 】 【 Auto power off after 10 minutes in sleep mode 】 【 Auto power off after 20 minutes in sleep mode .
【 S tart Setup 】 20 【 Exit Setup 】 Auto Scan ning Mode Press the trigge r after setup, the scanner will a utomatically startthe next scan after finish a successful reading; the scanner will stop until the trigger is pressed again. In the default mode, it is not allowed to repeatedly read the same barcode.
【 S tart Setup 】 【 Exit Setup 】 21 Intermittent Reading Mode Device will intermittent reading the barcode. W hether reading successful or not, the reading twice intervals are fixed, intermittent time default value is 1sec, this value can be change.
【 S tart Setup 】 22 【 Exit Setup 】 【 Set the Barcode Reading T i me 】 【 Set the Scanning T ime Interv als 】 The customer can select the sensitity according to the environmrnt, in order to increase the reading efficiency.
【 S tart Setup 】 【 Exit Setup 】 23 【 Continuous Reading 】 The scanner can set the time interval of scanning in the continuous reading mode.
【 S tart Setup 】 24 【 Exit Setup 】 To stop b arcode scanning by s ending t he stop c ommand in the terminal (such as PC) or reading the “Stop Simulating Trigger”, and require a 2 -Digit character passback ( such as 0A,0X,etc.
【 S tart Setup 】 【 Exit Setup 】 25 Decoding Sound Setup 【 T urn off Decoding Au dio 】 【 Intermediate Frequency - Weak 】 【 High Frequency - Laud 】 【 Low Frequency - Laud 】 【 H.
【 S tart Setup 】 26 【 Exit Setup 】 Other Setup Activ ate/Abort Temporary Mute 【 Active T empora ry M ute 】 【 Exit T empo r ary Mute 】.
【 S tart Setup 】 【 Exit Setup 】 27 Ch ap t er 3 Inquir y Command Introduction In order to inquire, the HR15 cradle information can feed back to the host by reading the setup barcode.
【 S t art Setup 】 28 【 Exit Setup 】 Inquire the Product-Name of the Cradle Inquire the Wireless Module Information In order to inquire, the HR15 cradle information can feed back to the host by reading the se tup barcode.
【 S tart Setup 】 【 Exit Setup 】 29 Chapter 4 Communicati on Setup HR15 Communication Mode Setup Communication modes include: Synchronous , A synchronous and Batch mode. Synchronous mode: the HR15 will transmit th e barcode data to the CD cradle after collecting when the network is connected.
【 S t art Setup 】 30 【 Exit Setup 】 【 9600 】 【 1 200 】 【 2 400 】 【 4800 】 【 14400 】 【 19200 】 【 38400 】 【 57600 】 【 1 1520 0 】.
【 S tart Setup 】 【 Exit Setup 】 31 Check Setu p 【 No Check 】 【 Even Check 】 【 Odd Check 】 Stop Bit 【 1 S top Bit 】 【 2 S top bits 】 Flow Contr ol Setup No Flow Control CTS .
【 S t art Setup 】 32 【 Exit Setup 】 Data Bit 8 Data Bits 8 Data Bits, no Chec k, 2 S top Bit 8 Data Bits, no Chec k, 1 S top Bit 8 Data Bits, Ev en Check, 2 S top Bit 8 Data Bits, Even Check, .
【 S tart Setup 】 【 Exit Setup 】 33 CD15 Cradle USB Function Setup USB Virt ual Keyboar d Function USB Virtual Keyboard Function USB Virt ual Serial Port Function USB Virtual Serial Port Functi.
【 S t art Setup 】 34 【 Exit Setup 】 5 th France 1 1st Brit ain 6 th T urkey F Set the Delay bet ween Charact ers The range of th e delay time be tween characters is from 0 to 75 ms, it takes 5ms as one level, totally 15 levels. The default value is 0ms.
【 S tart Setup 】 【 Exit Setup 】 35 Chapter 5 Data Form at Setup Introduction After successful barcode reading, the customer will receive a string of da ta which can be numbers, English characters symbols and so on, this string of data is the data information included in the barcode.
【 S t art Setup 】 36 【 Exit Setup 】 For ex ample, it is allowed to a dd custom prefix and set the prefix to character string “AB”, by readin g the barcode with data “123”, the scanner adds ”AB” before “123, and the host will receive “AB123”.
【 S tart Setup 】 【 Exit Setup 】 37 It is not Allow to Ad d AIMID Prefix Allow to Add AIMID Prefix Code ID Prefix Except for using AIM prefix to iden t ify different barcode, the customers also can u se CodeID prefix to perform the same function.
【 S t art Setup 】 38 【 Exit Setup 】 which will be set, according to priority. Set the Custom suffix For example: Set the custome suffix to “AGE” (the hexadecimal value is 0x 41/0x47/0x45) 1. Read the “ Start Setup” barcode . 2. Read the “Set the Custom Suffix ” barcode .
【 S tart Setup 】 【 Exit Setup 】 39 Set the End Mark Suffix Set the end m ark suf fix to 0x 0D, ,and mak e it can b e sent Set the end mark suffix to 0x0D,0x0A ,and make it can be sent For Example: Set the end mark of Windows Operation System to “newline” 1.
【 S t art Setup 】 40 【 Exit Setup 】 Chapter 6 Barc ode Parameter Setup Introduction Every kind of barcode has its o wn special character; the customer can adjust the scanner to suit the character changes by the setup barcode introduced in this chapter.
【 S tart Setup 】 【 Exit Setup 】 41 CodeID Setup Example: Set the CodeID of Code 128 to “p” (the hexadcimal value is 0x70): 1. Read the “ Start Setup ” b arcode. 2. Read the “CodeID S etup ” barcode. 3. Read the numeric barcode “7”, “0” (see the appendix— numeric barcode) 4.
【 S t art Setup 】 42 【 Exit Setup 】 9. Read the “ Exit Setup ” b arcode. UCC/EAN- 128 Restore Default Value By reading the barcode, the parameter setup of UCC/EAN-128 will be restored to the factory default state.
【 S tart Setup 】 【 Exit Setup 】 43 3. Read the numeric barcode “7”, “0” (see the appendix— numeric barcode) 4. Read the “Save” barcode.
【 S t art Setup 】 44 【 Exit Setup 】 Restore the Default Setup V alue of UCC/EAN -128 AIM 128 A llow to Read A IM-128 or n ot Allow to Read AIM- 128 Prohibit Reading AIM- 128 Note:the scanner w.
【 S tart Setup 】 【 Exit Setup 】 45 Read the barcode of “Set the M inimum Length Limit” to adjust the minimu m length limit . Read the barcode of “Set the M aximum Le ngth Limit.
【 S t art Setup 】 46 【 Exit Setup 】 Note:the scanner will become unable to read EAN -8 by reading the setup barcode “Prohibit Rea ding EAN -8 ”, thus, if the scanner is unable to read the EAN -8 , please try to read the setuo barcode “allow to read EAN-8 ”.
【 S tart Setup 】 【 Exit Setup 】 47 Note: By setting “Allow to Read 2 - Digit Ex tracode ”, the scanner can re ad the new barcode consisted of no rmal barcode and extracode, and the normal barcode without ex tracode.
【 S t art Setup 】 48 【 Exit Setup 】 Note:the scanner will become unable to read EAN- 13 by rea ding the setup barcode “Prohib it Reading EAN - 13”, thus, i f the scanner is unable to read the EAN-13, please try to read the setuo barcode “allow to read EAN - 13”.
【 S tart Setup 】 【 Exit Setup 】 49 Set Wheth er or not to Read 2-Digit Extr acode 2-Digit extended code means to add 2-digit numeric barcode behind the normal barcode.
【 S t art Setup 】 50 【 Exit Setup 】 Extend the Barcode into 13-Digits EAN-13, and lead by 0, means extend the data le ngth but keep the barcode type unchanged. Extend the Barcode and Transfer into EAN- 13 , means extend the barcode type and data length.
【 S tart Setup 】 【 Exit Setup 】 51 CodeID Setup Example: Set the CodeID of ISSN to “p” (the hexadcimal value is 0x70). 1. Read the “ Start Setup ” b arcode. 2. Read the “CodeID S etup ” barcode. 3. Read the numeric barcode “7”, “0” (see the appendix— numeric barcode) 4.
【 S t art Setup 】 52 【 Exit Setup 】 Code ID Setup To activate the setup function by reading “CodeID setup”, the n read and save t he hexadcimal value i naccordance with the character which will be set to the CodeID. CodeID Setup Example: Set the CodeID of ISB N to “p” (the hexadcimal value is 0x70).
【 S tart Setup 】 【 Exit Setup 】 53 digit . Send the Check Digit Do not Send the Check Digit CodeID Set up To activate the setup function by reading “C odeID setup”, then read a nd save the hex adcimal value inaccordance with the character which will be set to the CodeID.
【 S t art Setup 】 54 【 Exit Setup 】 Set Wheth er or not to Read 5-Digit Extr acode 5-Digit extended code means to add 5-Digit numeric barcode behind the normal barcode.
【 S tart Setup 】 【 Exit Setup 】 55 Do not Extend the Barcode Infornmation Extend the Barcode Infornmation into UPC-A Extend the Barcode Infornmation and T ype into UPC -A UPC-A Restore Default Value By reading the barcode, the parameter setup of UPC-A will be restored to the factory default state.
【 S t art Setup 】 56 【 Exit Setup 】 1. Read the “ Start Setup ” b arcode. 2. Read the “CodeID S etup ” barcode. 3. Read the numeric barcode “7”, “0” (see the appendix— numeric barcode) 4. Read the “Save” barcode.(see the appendix — numeric barcode) 5.
【 S tart Setup 】 【 Exit Setup 】 57 Set Wheth er or not to Read 5-Digit Extr acode 5-Digit extended code means to add 5-digit numeric barcode behind the normal barcode Do not read the 5-Digit E.
【 S t art Setup 】 58 【 Exit Setup 】 Interleaved 2 of 5”, thus, if the scanner is unable to read the I nterleaved 2 of 5, please try to read the setuo barcode “all ow to read Interleaved 2 of 5 ”.
【 S tart Setup 】 【 Exit Setup 】 59 Note: by setting “do not send the check digit”, if the data length except for the 1 character check di git is less than the minimum barcode reading limit, the barcode reading will be failed.
【 S t art Setup 】 60 【 Exit Setup 】 Allow to Read ITF-6 and T ransmit the Check Digit Note: if the setup of ITF-6 confilits with the setup of Int erleaved2 of 5 .
【 S tart Setup 】 【 Exit Setup 】 61 Prohibit Reading ITF- 14 Allow to Read ITF-14 and T ransmit the Check Digit Note: if the setup of ITF - 14 confilits with the setup of Interleaved2 of 5 , fo.
【 S t art Setup 】 62 【 Exit Setup 】 Allo w to Read Deutsc he14 or not Allow to Read Deutsche14,but do not send the check digit Prohibit Reading Deutsche14 Allow to Read Deutsche14 and send the.
【 S tart Setup 】 【 Exit Setup 】 63 Restore the Default Setup V alue of Deutsche12 Deutsche 12 Allo w to Read Deuts che 12 or n ot Allow to Read Deutsche12,but do not send the check digit Prohi.
【 S t art Setup 】 64 【 Exit Setup 】 COOP 25(Jap anese M atrix 2 of 5) Restore th e Default Val ue By reading the barcode, the parameter setup of COOP25 will be restored to th e factory default.
【 S tart Setup 】 【 Exit Setup 】 65 Check Setu p COOP25 barcode data does not compulsively include the check digi t, if c heck digit e x ists, then it is the last character. Check digit is calculated according to all the datas, for checking if the data is corr ect or not.
【 S t art Setup 】 66 【 Exit Setup 】 minimum length, then the scanner is only able to read t he barcodes w ith the minimum length and the t he maximum l ength; if the maximum length equals to the minimum length, then the scanner is only able to read the barcode w ith such length.
【 S tart Setup 】 【 Exit Setup 】 67 Check Setu p Matrix 2of 5 barcode data does not compulsively include the c heck digit, if c heck digit exists, th en it is the last character. Check digit is calculated according to all the datas, for checking if the data is corr ect or not.
【 S t art Setup 】 68 【 Exit Setup 】 Note : the maximum l ength limit of any 1D barcode must not exceed 255, if th e maximum length is shorter than the minimum length, then the scanner is onl.
【 S tart Setup 】 【 Exit Setup 】 69 3. Read the numeric barcode “7”, “0” (see the appendix— numeric barcode) 4. Read the “Save” barcode.
【 S t art Setup 】 70 【 Exit Setup 】 Set the Minimum Length Limit Set the Maximum Length Limit Note : the maximum l ength limit of any 1D barcode must not exceed 255, if th e maximum length i.
【 S tart Setup 】 【 Exit Setup 】 71 Code ID Setup Example: Set the CodeID ofStandard 25 to “p” (the hexadcimal value is 0x70). 1. Read the “ Start Setup ” b arcode. 2. Read the “CodeID S etup ” barcode. 3. Read the numeric barcode “7”, “0” (see the appendix— numeric barcode) 4.
【 S t art Setup 】 72 【 Exit Setup 】 Set the Barcode Readi ng Lengt h The s canner is only able to read th e Standa rd 25 with tramsmission c ontent l ength falls in the limited range, the range is consisted of the maximum val ue and minimum value in units of character , the Standard25 exceeds the range can not be read or transmitted.
【 S tart Setup 】 【 Exit Setup 】 73 CodeID Set up To activate th e set up function by reading “CodeID set up”, then read the hex adcimal value inaccordance with the character which will be set to the CodeID. Code ID Setup Example: Set the CodeID of Code39 to “p” (the hexadcimal value is 0x 70).
【 S t art Setup 】 74 【 Exit Setup 】 Set whet her to Send t he start and st op char acter or not There are two characters of “*”before and after the Code39 barcode data as the start and stop character. The system can set whether or not to send the start and stop character after s uccessful barcode reading.
【 S tart Setup 】 【 Exit Setup 】 75 maximum leng th; if the maximum length equals to the minimum length, then the scanner is only able to read the barcode with such length. Example: The steps of set the scanner read the Code 39 with barcode length between 8 to 12 characters.
【 S t art Setup 】 76 【 Exit Setup 】 Code ID Setup Example: Set the CodeID of Codabar to “p” (the hexadcimal value is 0x 70). 1. Read the “ Start Setup ” b arcode. 2. Read the “CodeID S etup ” barcode. 3. Read the numeric barcode “7”, “0” (see the appendix— numeric barcode) 4.
【 S tart Setup 】 【 Exit Setup 】 77 Start and Sto p Characte r Setup Do not Send the S tart and S top Characte r Send the S tart and S top Character Set “ABCD/ABCD” as the S tart and S to p.
【 S t art Setup 】 78 【 Exit Setup 】 4. Read the “Save” barcode.(see the appendix — numeric barcode) 5. Read the barcode of “Set the M aximum Len gth Limit” . 6. Read the numeric barcode “1” . 7. Read the numeric barcode “ 2” .
【 S tart Setup 】 【 Exit Setup 】 79 2. Read the “CodeID S etup ” barcode. 3. Read the numeric barcode “7”, “0” (see the appendix— numeric barcode) 4. Read the “Save” barcode.(see the appendix — numeric barcode) 5. Read the “Exit Setup” barcode.
【 S t art Setup 】 80 【 Exit Setup 】 Set the Minimum Length Limit Set the Maximum Length Limit Note : the maximum length limit of any 1D barcode must not exceed 255, if th e maximum length is.
【 S tart Setup 】 【 Exit Setup 】 81 1. Read the “ Start Setup ” b arcode. 2. Read the “CodeID S etup ” barcode. 3. Read the numeric barcode “7”, “0” (see the appendix— numeric barcode) 4. Read the “Save” barcode.(see the appendix — numeric barcode) 5.
【 S t art Setup 】 82 【 Exit Setup 】 able to read the Code 11 with 4 characters. ) Set the Barcode Readi ng Lengt h The sc anner is onl y able to read th e Code 11 with tramsmission content len.
【 S tart Setup 】 【 Exit Setup 】 83 Restore the Default Setup V al ue of Plessey Allo w to Read Plessey or not Allow to Read Plessey Prohibit Reading Plessey Note: the scanner will become unabl.
【 S t art Setup 】 84 【 Exit Setup 】 scann er will indicate “barcode reading failed” Note: by setting “do not send the check digit”, if the data length except for the 1 character check d igit is less than the minimum barcode reading limit, the barcode reading will be failed.
【 S tart Setup 】 【 Exit Setup 】 85 MSI-Plessey Restore th e Default Val ue By reading the barcode, the parameter setup ofMSI-Plessey will be restored to the factory default state.
【 S t art Setup 】 86 【 Exit Setup 】 No Check Single Check MOD10 Double Check MOD10/MOD10 Double Check MOD10/MOD1 1 Do not Send the Check Digit Send the Check D igit Note: by setting “do not .
【 S tart Setup 】 【 Exit Setup 】 87 Note : the maximum l ength li mit of any 1D barcode must not exceed 255, if the maximum len gth is shorter t han the minimum le n gth, then the s canner is.
【 S t art Setup 】 88 【 Exit Setup 】 5. Read the “Exit Setup” barcode. PDF417 Restore th e Default Val ue By reading the barcode, the parameter setup of PDF417 will be restored to the factory default state.
【 S tart Setup 】 【 Exit Setup 】 89 MicroPDF417 Restore th e Default Val ue By reading the barcode, the parameter setup of MicroPDF417 will be restored to the factory default sta te .
【 S t art Setup 】 90 【 Exit Setup 】 Chapter 7 A ppendix Default Setup T able Parameters Default Setup Remark General Setup Setup Barcode Function On Send Setup Barcode Off Working Mode Manual .
【 S tart Setup 】 【 Exit Setup 】 91 Parameters Default Setup Remark Data Bits 8 bits USB Virtual Keyboard On Virtual Keyboard Layout The First, American English key board Delay between Characte.
【 S t art Setup 】 92 【 Exit Setup 】 Parameters Default Setup Remark Enable Off Minmum Length 1 EAN-8 Enable On Send the Check Character On Read 2-Digits Extracode Off Read 5-Digits Extracode O.
【 S tart Setup 】 【 Exit Setup 】 93 Parameters Default Setup Remark Use 10 digits ISBN Off UPC-E Enable On Send the Check Character On Read 2-Digits Extracode Off Read 5-Digits Extracode Off Ex.
【 S t art Setup 】 94 【 Exit Setup 】 Parameters Default Setup Remark Maximum Length 255 Minmum Length 6 ITF -6 Enable Off Send Check Character On ITF - 14 Enable Off Send Check Character On Deu.
【 S tart Setup 】 【 Exit Setup 】 95 Parameters Default Setup Remark Check Off Send Check Character Off Maximum Length 255 Minmum Length 6 At less 3 Industrial 25 Enable ? Check ? Send Check Cha.
【 S t art Setup 】 96 【 Exit Setup 】 Parameters Default Setup Remark Minmum Length 4 Codabar Enable On Check Off Send Check Character Off Do not Send S tart and S to p Character Off Se lect one.
【 S tart Setup 】 【 Exit Setup 】 97 Parameters Default Setup Remark Send Check Character On 1 Digit MOD10 Check On 2 Digits MO D10/ M OD10 Check Off 2 Digits MO D10/ M OD1 1 Check Off Auto 2 Di.
【 S t art Setup 】 98 【 Exit Setup 】 Parameters Default Setup Remark GS1 Databar Enable On PDF417 Enable On MicroPDF417 Enable On.
【 S tart Setup 】 【 Exit Setup 】 99 A IM ID T able Barcode AIM ID Possible AIM ID Parameters Code 128 ]C0 UCC/EAN- 128 ]C1 AIM 128 ]C2 ISBT 128 ]C4 EAN -8 ]E4 EAN - 13 ]E0 EAN -13 with Addon ]E.
【 S t art Setup 】 100 【 Ex it Setup 】 Industrial 25 ]S0 S tandard 25 ]R0 Code 39 ]Am 0,1,3,4,5,7 Codabar ]Fm 0,2,4 Code 93 ]G0 Code 1 1 ]Hm 0,1,3 Plessey ]P0 MSI-Plessey ]Mm 0,1 GS1 Databar ]e0 PDF417 ]Lm 0,1,2 MicroPDF417 ]Lm 3,4,5 Reference: 1.
【 S tart Setup 】 【 Exit Setup 】 101 CodeID T able 条码类型 Barcode Code ID Code 128 j UCC/EAN- 128 u AIM 128 f ISBT 128 t EAN -8 g EAN - 13 d ISSN n ISBN B UPC-E h UPC-A c Interleaved 2 of.
【 S t art Setup 】 102 【 Ex it Setup 】 Code 93 y Code 1 1 z Plessey p MSI-Plessey m GS1 Databar R PDF417 P MicroPDF417 M Dat a Barcode After reading the data barcode, please read “save” in the next page to svae the data barcode setup.
【 S tart Setup 】 【 Exit Setup 】 103 3 7 8 9 A B C D E F Save and A bort the Setup After reading the data barcod e, please read “save” to save the data. If re ading error occurs, e x cept for re -configuration, the costomer can also abort the error data.
【 S t art Setup 】 104 【 Ex it Setup 】 Save Data Parameter Abort the Present Command Abort one of the Presnet Setup of the Dat a Parameter Abort one of the Presnet Setup of the Data Parameter.
An important point after buying a device Newland NLS-HR1550-3E (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Newland NLS-HR1550-3E yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Newland NLS-HR1550-3E - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Newland NLS-HR1550-3E you will learn all the available features of the product, as well as information on its operation. The information that you get Newland NLS-HR1550-3E will certainly help you make a decision on the purchase.
If you already are a holder of Newland NLS-HR1550-3E, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Newland NLS-HR1550-3E.
However, one of the most important roles played by the user manual is to help in solving problems with Newland NLS-HR1550-3E. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Newland NLS-HR1550-3E along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center