ST-nXm-U-HD (Multi-user / Universal KVM Switch) INSTALLATION / USER GUIDE MAN001 Rev Date 1/6/2003 NT I NETWORK TECHNOLOGI ES INCORPORATE D Te l:33 0-5 62 -70 70 Fax :33 0-5 6 2-1 999 1275 D an ner D r Aurora, OH 44202 www.
WARRANTY INFORMATION The warranty period on this product (parts and l abor) is one (1 ) year from the date of purch ase. Please contact Network Technologies Inc at (800) 742-8324 (800-RGB-T ECH) or (330) 562-7070 or v isit our website at http://www.nti1.
Table of Contents Introduc tion ................................................................................................................... ................................................ 1 Defini tions........................................
Command Pr otocol ............................................................................................................... ................................... 17 RS232 INTERFACE TEST PR OGRAM DESCRIPTION ........................................
1 Introduction The NTI ST-nXm-U-HD (als o known as NODEMUX-HD) is a multi- user / Univ ersal Multi-Platform Matrix KVM switch, (n= number of users, m= number of CPUs) with high dens it y construction to require less rack space.
2 Interface cables and adapters are not included and must be purchased separately . A cable for each CPU being connected to the switch: PS/2 CPU to Switch • VMTINT-xx-MM for video, ke yboard and mou.
3 Additional Features • Users can work individually or share the sam e CPU. • Up to n users can work with m CPUs where n and m are the switch size acquired. • High density (similar to SCSI) input an d output ports that inte rface cables plug into adapt to PS/2 and SUN platform devices.
4 Installation Turn OFF power to all CPUs that will be conne cted to the NTI ST-nXm-U-HD switch before connecting or disconnectin g any cables. 1. If using RS-232 Control see RS-232 section for more information.
5 Figure 2- Connect CPUs to switch usin g interface cable s 7. Plug the NTI Switch into an AC power outlet. 8. Turn ON power to the NTI Switch, the LCD should illuminat e. 9. Turn ON power to any or all CPUs connecte d to the NTI Switch. NOTE: The order in which the CPUs and switch are tu rn ed ON does not matter.
6 Using the ST-nXm-U-H D Switch Basic Operation This unit enables any user to access a ny CPU at any time with no restrictions or limitatio ns. Users can even share a CPU and work on the same project – each from their own conso le. Reso lution is sup ported through 1900x12 00 with no degradation – guaranteed.
7 OSD Control OSD superimposes a menu system on the user ’s video screen with a list of all connected CPUs. OSD allows CPUs to be named (with up to 12 character names). OSD then allo ws selection of CPUs b y that name. Connected CP Us can be listed b y name or by port number.
8 User Login Mode User Login Mode requires a user to l ogi n with a user name and pas s word from the list created by the administrator. With securi ty enabled, the user will be locked to the current CPU an d the logi n screen will remain on the monitor unti l the user logs in.
9 Fi gure 4- A dministration Mode Menu Function: Keystroke: Enter User Name List Mode Selects the idle time in minutes Exit Administration Mode and return to previous mode Port Status Mode Port Status mode enables the administrator to view extend ed status information about the port selected in Administration mode.
10 Administrator Pas sword (cont'd) Function: Keystroke: Save new password. (The administrator will be prompted for a Yes or No confirmation) Return to Admi nistration Mode User Name List To enter the User Name List press <U> from the Administration Mode menu.
11 User Access Functions Command Mode In order to control the switch with the keyboard, Command Mode must be enabl ed. T o enable Command Mode from the keybo ard: Press All the status lights on the keyboard w ill illuminate to indic ate that Command Mode is enabled.
12 Command Mode (Cont 'd) Function: Keystroke: Enter Edit Mode (Only available if administrator is logged in) Selects scan time in seconds Enter Maintenance Mode Display Help Menu Select a specif.
13 Edit Mode To activate Edit Mode press <Ctrl> + <E> from the Command Mode menu. Edit Mode allows only the administrator to modify the names of the CPUs connected to the switch. Names of CPUs can b e up to 12 characters in length. Characters t yped can be upper or lo wer case.
14 Search Mode (cont 'd) Function: Keystroke: Select the next port Add a character to the search string and select the best matching CPU name Exit Search Mode, return to Command mode Maintenance Mode To enter Maintenance Mode (s ee Fig. 8) press <Ctrl>+<M> from the Command Mode menu.
15 Maintenance Mode (Cont 'd) Function: Keystroke: Log current user out and return to User Login Mode. Save OSD window parameters for the port Return to Command Mode NOTE: Based on different scan rates, the OSD window may appear in different area s of the monitor as d ifferent CPU ports are selected.
16 SUN’s Startup Keys With a Sun CPU attached to the switch, the fo llowing emergenc y startu p keys are supported: Key Function Stop Bypass POST Stop-A Abort Stop-D Enter diagnostic mode Stop-F Ent.
17 RS232 Control Remote Connection The RS232 Interface is designed to control t he s witch via serial (RS232) daisy chain co n nection from any CPU or other controlle r with an RS232 communications port.
18 CS - change single USER channe l FORMAT: CS AA,XX,YY<CR> CS = "change single USER" command fol lowed by at least one space AA = unit address XX = CPU to connect YY = USER to change .
19 9) Read Connection for KVM Output/User - read what input is connected to the specified output (KVM ports only) a) Read Connection for Audi o Output/User - read what input is connected to the specif.
20 Matrix Switcher's Control Progr am For Windows 9X, NT, and 2000 The Matrix Switcher's Control Pro gram is an easy and po werful gr aphical program that controls NT I matrix switches through an RS232 interface. The Matrix Switcher ' s Control Program is on a 3-1/4" floppy disc pack aged with the ST -nXm-U-HD switch.
21 ST- MX Expansion Units In order to be able to expand the current ST -nXm-U-HD product or go beyond the 8/16 CPU limit on the ST-nXm-U-HD, the ST- MX expansion unit can be us ed to combine, or bank, multiple sw itches together to be controll ed from one central workstation.
22 Appendix B- Genera l Information DESCRIPTION SPECIFICATION Dimensions 19"W x 10" D x 1.75" H Operating temperature 0 ° C - 55 ° C (32 ° F - 131 ° F) Power requirements 120 or 240.
23 SERIAL NO: DATE: INSPECTED BY: ST-2x8-U-HD ST-4x8-U-HD ST-4x8-U-HD ST-4x16-U-HD OPTION: Dual Redundant Power Supply.
An important point after buying a device Network Technologies ST-NXM-U-HD (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Network Technologies ST-NXM-U-HD yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Network Technologies ST-NXM-U-HD - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Network Technologies ST-NXM-U-HD you will learn all the available features of the product, as well as information on its operation. The information that you get Network Technologies ST-NXM-U-HD will certainly help you make a decision on the purchase.
If you already are a holder of Network Technologies ST-NXM-U-HD, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Network Technologies ST-NXM-U-HD.
However, one of the most important roles played by the user manual is to help in solving problems with Network Technologies ST-NXM-U-HD. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Network Technologies ST-NXM-U-HD along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center