USER GUIDE AND SPECIFICATIONS NI USB-9421 8-Channel, 24 V Logic, Si nking Digital Input Device This user guide describes how to use the National Instruments USB-9421 and lists the de vice specifications. In th is user guide, the NI USB-9421 with screw terminal and the NI USB-94 21 with D-SUB are referred to inclusi vely as the NI USB-9421 .
NI USB-9421 U ser Guide and Specifications 2 ni.com Dimensions Figures 2 and 3 sho w the NI USB-9421 device dimensions. Figure 2. NI USB-9421 (Screw T erminal) Device in Millimeters (Inches) Figure 3. NI USB-9421 (D-SUB) Device in Millimeters (Inches) Hi- S peed U S B Carrier NI U S B-9162 140.
© National Instruments Corporation 3 NI USB-9421 User Guid e and Specifications Safety Guidelines Operate the NI USB-9421 on ly as described in thes e operating instructions.
NI USB-9421 U ser Guide and Specifications 4 ni.com Related Documentation Each application software package an d driv er includes inform ation about writing applications for taking measur ements and controlling measurement devices. The follo wing references to documents assume you have NI-D A Qmx 8.
© National Instruments Corporation 5 NI USB-9421 User Guid e and Specifications • T aking Measurements —Contains the conceptual and how-to information you need to acquire and analyze measurement data in LabVIEW , including common measurements, measurement fundamentals, NI-DA Qmx key concepts, and device considerations.
NI USB-9421 U ser Guide and Specifications 6 ni.com ANSI C without NI Application Software The NI-D A Qmx Help contains API ov erviews and general information about measurement concepts. Select Start»All Programs»National Instruments»NI-D A Q»NI-DA Qmx Help .
© National Instruments Corporation 7 NI USB-9421 User Guid e and Specifications T raining Courses If you need more help getting started developing an appli cation with NI products, NI offers training courses. To enroll in a course or obtain a detailed course outline, r efer to ni.
NI USB-9421 U ser Guide and Specifications 8 ni.com 3. Align the I/O module with the carrier , as sho wn in Figure 4. Figure 4. Module Installation 4. Squeeze the latches and insert the NI 9421 module into the NI USB-9162 carrier .
© National Instruments Corporation 9 NI USB-9421 User Guid e and Specifications Mounting the NI USB-9421 to a Panel Threaded inserts are located in the NI USB-9421 for mounting it to a panel.
NI USB-9421 U ser Guide and Specifications 10 ni.com Wiring the NI USB-9421 Device Caution A high v oltage screw terminal backshell must be installed when using hazardous voltages (>42.4 V pk , 60 VDC). Note T able 2 illustrates the accessories a v ailable from ni.
© National Instruments Corporation 11 NI USB-9421 User Gu id e and Specifications Each channel of the NI USB-9421 has a terminal or pin, DI, to which you can connect voltage or current signals. The NI USB-9421 also has a common terminal or pin, COM, that is internally connected to the isolated reference of the module.
NI USB-9421 U ser Guide and Specifications 12 ni.com Figure 7. Pin Assignments Connecting Devices to the NI USB-9421 The NI USB-9421 has sinking inputs , meaning that when current goes through or voltage is applied to the DI termi nal or pin, DI provides a path to ground for the current or voltage.
© National Instruments Corporation 13 NI USB-9421 User Gu id e and Specifications Figure 8. Connecting a Device to the NI USB-9421 (3-Wire Device Shown) The NI USB-9421 channel registers as ON when the sourcing-output device applies a v oltage or dri ves a cu rrent to DI that is in the input ON range.
NI USB-9421 U ser Guide and Specifications 14 ni.com Figure 10. Assembled High Voltage Screw T erminal Back shell Specifications The following specifications are ty pical for the range 0 to 60 °C unless otherwise noted. All voltage s are relative to COM unless otherwise no ted.
© National Instruments Corporation 15 NI USB-9421 User Gu id e and Specifications Bus Interface USB specification ..... .............. ............... USB 2.0 Hi-Speed Physical Characteristics Dimensions With screw terminal . .............. .........
NI USB-9421 U ser Guide and Specifications 16 ni.com NI USB-9421 with D-SUB Safety Voltages Channel-to-COM .......... ........... .............. .30 V max Isolation Channel-to-channel.............. ........ ....No isolation betw een channels Channel-to-earth g round Withstand .
© National Instruments Corporation 17 NI USB-9421 User Gu id e and Specifications Operating humidity (IEC 60068-2-56) ................. ......... ......... 10 to 90% RH, noncondensing Storage humidity (IEC 60068-2-56) ................. ......... ....
National Instruments, NI, ni.com, and LabVIEW are tradem arks of National Instruments Corporation. Refer to t he Terms of Use section on ni.com/legal for more information abou t National Instruments trademarks. Other product and compan y names mentioned herein are trademarks or trade names of their respective companie s .
An important point after buying a device National Instruments 8-Channel, 24 V Logic, Sinking Digital Input Device (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought National Instruments 8-Channel, 24 V Logic, Sinking Digital Input Device yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data National Instruments 8-Channel, 24 V Logic, Sinking Digital Input Device - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, National Instruments 8-Channel, 24 V Logic, Sinking Digital Input Device you will learn all the available features of the product, as well as information on its operation. The information that you get National Instruments 8-Channel, 24 V Logic, Sinking Digital Input Device will certainly help you make a decision on the purchase.
If you already are a holder of National Instruments 8-Channel, 24 V Logic, Sinking Digital Input Device, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime National Instruments 8-Channel, 24 V Logic, Sinking Digital Input Device.
However, one of the most important roles played by the user manual is to help in solving problems with National Instruments 8-Channel, 24 V Logic, Sinking Digital Input Device. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device National Instruments 8-Channel, 24 V Logic, Sinking Digital Input Device along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center