Instruction/ maintenance manual of the product GVF40N Napoleon
Go to page of 24
1 W415-0319 / D / 08.03.05 INST ALLER: THESE INSTRUCTIONS MUST BE CONVEYED TO AND REMAIN WITH THE HOMEOWNER. Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON L4M 4Y8 Canada • (705)721-1212 • fax(705)722-6031 www .napoleonfireplaces.com • ask@nap oleon.
2 W415-0319 / D / 08.03.05 Hood Louvre Bracket Hinge Screen Louvre Installation & Removal Heat Shield S tand Off Removal Logo Placement 16-17 O PTIONS Patented Catalytic Glass Door Blower Installa.
3 W415-0319 / D / 08.03.05 NAPOLEON gas fireplaces are manufactured under the strict Standard of the world recognized ISO 9001 : 2000 Quality Assurance Certificate. NAPOLEON products are designed with superior components and materials, assembled by trained craftsmen who take great pride in their work.
4 W415-0319 / D / 08.03.05 This fireplace may be installed in an aftermarket per- manently located, manufactured (mobile) home, where not pr ohibited by local codes . This fireplace is only for use with the type of gas indi- cated on the r ating plate .
5 W415-0319 / D / 08.03.05 This heater shall not be installed in a confined space or unusually tight construction unless pro- visions are provided for adequate combustion and ventila tion air .
6 W415-0319 / D / 08.03.05 50 If in this example a solid door separates Room 1 from Room 2, the volume of Room 2 could not be used. In this case the maximum BTU/h would be: Maximum BTU/h: 800 x 1000 =.
7 W415-0319 / D / 08.03.05 FIGURES 4 a-d PENINSULA OPEN-END SEE-THRU 4-SIDED.
8 W415-0319 / D / 08.03.05 Note: In order to avoid the possibility of exposed insula- tion or vapour barrier coming in contact with the fireplace body , it is recommended that the walls of the fireplace enclosure be “finished” (ie: drywall/sheetrock), as you would finish any other outside wall of a home.
9 W415-0319 / D / 08.03.05 Combustible materials may be installed flush with the front of the fireplace but must not cover any of the black face- areas of the fireplace. Non-combustible material (brick, stone or ceramic tile) may protrude in these areas.
10 W415-0319 / D / 08.03.05 FIGURE 14 Note: In order to avoid the possibility of exposed insula- tion or vapour barrier coming in contact with the fireplace body , it is recommended that the walls of the fireplace enclosure be “finished” (ie: drywall/sheetrock), as you would finish any other outside wall of a home.
11 W415-0319 / D / 08.03.05 Install the base panels as illustrated in steps 1-4 on page 9. Both side panels sit under the bracket tab . Holding the side panel in position, bend down the tab to secure.
12 W415-0319 / D / 08.03.05 Combustible materials may be installed flush with the front of the fireplace but must not cover any of the black face- areas of the fireplace. Non-combustible material (brick, stone or ceramic tile) may protrude in these areas.
13 W415-0319 / D / 08.03.05 PHAZER TM logs, glowing and charcoal embers, exclusive to Napoleon fireplaces, provide a unique and realistic glow- ing effect that is dif ferent in every installation. T ake the time to carefully position the embers for a maximum glowing effect.
14 W415-0319 / D / 08.03.05 The curtain mesh must be kept fully closed during opera- tion to help prevent accidental burns from occurring. The heater must not be used when the hood is re- moved. Hook the hood over the lip of the curtain support plate.
15 W415-0319 / D / 08.03.05 L36 LOUVRE INST ALLA TION FIGURE 32 a-c HOOD Attach the hood by pressing the top flange into the clips along the top of the louvre opening. Secure using a screw through the centre slot. LOWER LOUVRES Insert the hinge clips into the slots located at the bottom left and right corners of the unit.
16 W415-0319 / D / 08.03.05 Notes: Ornamental insets can not be used in conjunction with the catalytic door When using a catalytic door , glassed doors must be used on all other side or end openings. This unique patented catalytic system was designed to provide unparalleled safety and peace of mind.
17 W415-0319 / D / 08.03.05 Remove the thermodisc bracket from the top of the firebox. Remove the thermodisc from the bracket supplied in the blower kit and install the thermodisc into the fireplace bracket. Then replace the bracket in the location it was removed.
18 W415-0319 / D / 08.03.05 When lighting and re-lighting, the gas knob cannot be turned from pilot to off unless the knob is depressed. 1. STOP! Read the above safety information on this la- bel. 2. Set the thermostat to lowest setting. 3. Turn off all electric power to the fireplace.
19 W415-0319 / D / 08.03.05 THIS PROCEDURE MUST BE PERFORMED BY A QUALIFIED SERVICE PERSON! Inspect the pilot for any visible contamination or debris (usually lint, pet hair , spider webs, carpet fibre, etc.) and remove. Disconnect the pilot from the pilot tubing line.
20 W415-0319 / D / 08.03.05 Contact your dealer for questions concerning prices and availability of replacement parts. Normally all parts can be ordered through your Napoleon dealer or distributor .
21 W415-0319 / D / 08.03.05.
22 W415-0319 / D / 08.03.05 Main burner goes out; pilot stays on. Pilot flame is not large enough or not engulfing the thermopile - service or replace Oxygen Depletion Sensor System - correct piping and/or regulator to provide correct pressure Thermopile shorting - clean thermopile connection to the valve.
23 W415-0319 / D / 08.03.05 White / grey film forms on the glass of the optional cata- lytic door . Sulphur from fuel is being deposited on glass, logs or combustion chamber sur- faces. - clean the glass with a recommended gas fireplace glass cleaner .
24 W415-0319 / D / 08.03.05 W olf Steel Fireplace Ser vice Histor y This fireplace must be serviced annually depending on usage. Date Service T echnician Name Service Performed Special Concerns Dealer.
An important point after buying a device Napoleon GVF40N (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Napoleon GVF40N yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Napoleon GVF40N - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Napoleon GVF40N you will learn all the available features of the product, as well as information on its operation. The information that you get Napoleon GVF40N will certainly help you make a decision on the purchase.
If you already are a holder of Napoleon GVF40N, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Napoleon GVF40N.
However, one of the most important roles played by the user manual is to help in solving problems with Napoleon GVF40N. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Napoleon GVF40N along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center