Instruction/ maintenance manual of the product GVF36N Napoleon
Go to page of 20
1 W415-0297 / D / 04.03.03 CERTIFIED UNDER AMERICAN NA TIONAL ST ANDARDS, ANSI Z21.11.2, VOL UME II FOR UNVENTED ROOM HEA TERS. UNVENTED MILLIVOL T SYSTEM INST ALLA TION AND OPERA TION INSTRUCTIONS FO.
2 W415-0297 / D / 04.03.03 WARNING • • Under no circumstances should this heater be modified. • Pr ovide adequate ventila tion and combustion air . Pro vide adequate accessibility c learance f servicing and oper ating the heater . Nev er obstruct the fr ont opening of the heater .
3 W415-0297 / D / 04.03.03 NAPOLEON gas fireplaces are manufactured under the strict Standard of the world recognized ISO 9001 : 2000 Quality Assurance Certificate. NAPOLEON products are designed with superior components and materials, assembled by trained craftsmen who take great pride in their work.
4 W415-0297 / D / 04.03.03 THIS GAS FIREPLACE SHOULD BE INST ALLED AND SERVICED BY A QUALIFIED INST ALLER to conform with local codes. Installation practices vary from region to re- gion and it is imp.
5 W415-0297 / D / 04.03.03 ROOM 2 ROOM 1 This heater shall not be installed in a confined space or unusually tight construction unless provisions are pro- vided for adequa te combustion and ventila tion air .
6 W415-0297 / D / 04.03.03 1. Move the fireplace into position and secure using the nailing tabs and/or secure to the floor through the ¼"ø holes located at either end of the base.
7 W415-0297 / D / 04.03.03 NAILING TA B T o install the fireplace face flush with the finished wall, position the framework to accommodate the thick- ness of the finished wall. Bend out the four nailing tabs, attached on either side of the fireplace and secure to the 2x4 framing.
8 W415-0297 / D / 04.03.03 The curtain mesh must be kept fully closed during opera- tion to help prevent accidental burns from occurring. The heater must not be used when the hood is removed.
9 W415-0297 / D / 04.03.03 PHAZER TM logs and glowing embers exclusive to Napoleon Fireplaces, provide a unique and realistic glowing effect that is different in every inst allation. T ake the time to care- fully position the glowing embers for a maximum glowing effect.
10 W415-0297 / D / 04.03.03 UPPER L OUVRES: In- sert the upper louvres into the slots on both brackets. Press the top flange of the hood into the four clips located along the top of the unit as shown. L OWER LOUVRES: At- tach each hinge to the fire- bo x with 2 screws.
11 W415-0297 / D / 04.03.03 NO TE : ORNAMENT AL INSETS CAN NOT BE USED IN CONJUNCTION WITH THE CA T AL YTIC DOOR This unique patented catalytic system was designed to provide unparalleled safety and peace of mind.
12 W415-0297 / D / 04.03.03 Attach the connectors from the black and red wires to the blower . Attach and secure the variable speed switch using the nut pro- vided. Plug the harness cord into the receptacle. The wire harness provided in this kit is a univer- sal harness .
13 W415-0297 / D / 04.03.03 FIGURE 27 This optional kit is meant to be used only in conjunction with the GD65 Fan Kit, which may be ordered from your Wolf Steel /Napoleon dealer.
14 W415-0297 / D / 04.03.03 P I N O L O T F F O When lighting and re-lighting, the gas knob cannot be turned from pilot to off unless the knob is depressed. 1. STOP! Read the above safety information on this la- bel. 2. Set the thermostat to lowest setting.
15 W415-0297 / D / 04.03.03 This procedure must be performed by a qualified service person! Inspect the pilot for any visible contamination or debris (usually lint, pet hair , spider webs, carpet fibre, etc.) and remove. Disconnect the pilot from the pilot tubing line.
16 W415-0297 / D / 04.03.03 Contact your dealer or the factory for questions concerning prices and policies on replacement parts. Normally all parts can be ordered through your Napoleon dealer or distribu- tor . When ordering replacement parts always give the follow- ing information: 1.
17 W415-0297 / D / 04.03.03.
18 W415-0297 / D / 04.03.03 Main burner goes out; pilot stays on. Pilot flame is not large enough or not engulfing the thermopile - service or replace Oxygen Depletion Sensor System - correct piping and/or regulator to provide correct pressure Thermopile shorting - clean thermopile connection to the valve.
19 W415-0297 / D / 04.03.03 Pilot goes out while standing; Main burner is in 'OFF' position. Gas piping is undersized. - turn on all gas appliances and see if pilot flame flutters, dimin- ishes or extinguishes, especially when main burner ignites.
20 W415-0297 / D / 04.03.03 Wolf Steel Fir eplace Ser vice Histor y This fireplace must be serviced annually depending on usage. Date Service T echnician Name Service Performed Special Concerns Dealer.
An important point after buying a device Napoleon GVF36N (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Napoleon GVF36N yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Napoleon GVF36N - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Napoleon GVF36N you will learn all the available features of the product, as well as information on its operation. The information that you get Napoleon GVF36N will certainly help you make a decision on the purchase.
If you already are a holder of Napoleon GVF36N, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Napoleon GVF36N.
However, one of the most important roles played by the user manual is to help in solving problems with Napoleon GVF36N. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Napoleon GVF36N along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center