1 W415-0098 / C / 04.19.06 INST ALLER: THESE INSTRUCTIONS MUST BE CONVEYED TO AND REMAIN WITH THE HOMEOWNER. Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON L4M 4Y8 Canada • (705)721-1212 • fax(705)722-6031 www .napoleonfireplaces.com • ask@napoleon.
2 W415-0098 / C / 04.19.06 Pg 2 - 4 INTRODUCTION Warranty General Instructions General Information Care of Glass & Plated Parts 5 LOCA TION & CLEARANCES 6-11 DIRECT VENT SPECIFICS MODEL GDS50 .
3 W415-0098 / C / 04.19.06 NAPOLEON products are manufactured under the strict Standard of the world recognized ISO 9001 : 2000 Quality Assurance Certificate. NAPOLEON products are designed with superior components and materials, assembled by trained craftsmen who take great pride in their work.
4 W415-0098 / C / 04.19.06 FOR YOUR SA TISF ACTION, THIS ST OVE HAS BEEN TEST -FIRED TO ASSURE ITS OPERA TION AND QUAL- ITY! Minimum inlet gas supply pressure is 4.5 inches water column for natural gas and 1 1 inches water column for propane. Maximum inlet gas pressure is 7 inches water column for natural gas and 13 inches water column for propane.
5 W415-0098 / C / 04.19.06 As long as clearance to combustibles is kept within the required distances, the most desirable and benefical location for a Napoleon stove is in the centre of a building, thereby allowing the most efficient use of the heat created.
6 W415-0098 / C / 04.19.06 HORI ZONTA L RUN NOT TO EXCEE D VERTI CAL RI SE For optimum flame appear- ance and stove perfor- mance, keep the vent length and number of el- bows to a minimum. On extreme vent configura- tions, allow several min- utes (5-15) for the flame to stabilize after lighting.
7 W415-0098 / C / 04.19.06 * * * * * Recommended to pr event condensa tion on windows and thermal break age ** ** ** ** * * It is recommended to use a hea t shield and to maximize the distance to vinyl c lad sof fits . *** *** *** *** ** * The periscope GD-201 r equires a minim um 18 inc hes c learance fr om an inside corner .
8 W415-0098 / C / 04.19.06 57" first run 72" second run 48" Use the chart on this page to calculate horizontal runs for vertical rises between 29 and 57 inches. FIGURE 7. When calculating maximum run lengths, include 10 feet for each 90° elbow or 5 feet for each 45° elbow .
9 W415-0098 / C / 04.19.06 This application occurs when venting through an ex- terior wall. FIGURES 5, 6, & 13. Having deter- mined the air terminal loca- tion, cut and frame a hole in an exterior wall with a mini- mum square or round open- ing of 9".
10 W415-0098 / C / 04.19.06 ST O RM C OLLA R FLA S H IN G CAUL KI NG WE A TH ER S E A LA N T 2” AI R I NL E T BAS E FIGURE 20 ROOF SUPPORT FIGURE 18 1.
11 W415-0098 / C / 04.19.06 In Canada, mobile home installation may be vented hori- zontally or vertically . In the United S tates, it may only be installed vertically . See "V ertical V enting" or "Horizontal Air T erminal Installation" for inst allation.
12 W415-0098 / C / 04.19.06 Follow the instructions for " Wall and Ceiling Protection". ADAPTER INST ALLA TION FIGURE 23 1. Remove the spill switch bracket from the rear of the adapter . 2. Gently pull the two wire terminals (located inside the 7" flue collar at the top of the stove) out approximately 8 inches.
13 W415-0098 / C / 04.19.06 Remove nails from the shingles above and to the sides of the chimney . Place the flashing over the vent pipe and slide it underneath the sides and upper edge of the shingles. Ensure that the vent pipe is properly centered within the flashing, giving a 3/4" margin all around.
14 W415-0098 / C / 04.19.06 Read the section on opening the door in "Finish- ing" prior to proceeding to prevent damaging the unit. Bring the gas line to the stove through either the opening in the pedestal back or through the floor directly beneath the pedestal base.
15 W415-0098 / C / 04.19.06 When opening the fire viewing door , a simple procedure must be followed in order to not damage the door . First open the valve control door . Next open both side doors fully . Pull the latch handles towards you and release each catch.
16 W415-0098 / C / 04.19.06 LOG PLACEMENT POSITIONING THE LOGS IMPROPERL Y WILL CAUSE FLAME IMPINGEMENT AND CARBONING . PHAZER TM logs and charcoal embers strips, exclusive to Napoleon Fireplaces, glow when exposed to direct flame and provide a unique and realistic glowing effect that is dif- ferent in every installation.
17 W415-0098 / C / 04.19.06 This is a thermally activated switch, attached to the back of the chimney adapter , which senses the change in temperature and shuts down the gas valve in the event of a severe downdraft of air or a blocked or disconnected vent.
18 W415-0098 / C / 04.19.06 TURN OFF THE GAS AND UNPLUG ELECTRI- CAL POWER BEFORE SERVICING THE ST O VE! CAUTION: Label all wires prior to disconnection when ser- vicing controls. Wiring errors can cause improper and dan- gerous operation. V erify proper operation after servicing.
19 W415-0098 / C / 04.19.06 RELIEF DOOR GASKET RELIEF DOOR TWIN BLOWER P I P I L O T N O L O T H I L O F F O BLOW ER THERMODISC black ground VARIABLE SPEED SWITCH white 1. Turn off the electrical power and the gas supply to the stove. 2. Open the lower louvre control door , the two side doors, and the fire viewing door .
20 W415-0098 / C / 04.19.06 Remove the pilot screw cap. Adjust the pilot screw to pro- vide properly sized flame. Turn in a clockwise direction to reduce the gas flow .
21 W415-0098 / C / 04.19.06 GD175 WALL TERMINAL KIT 47 BM6790 90 ° ELBOW - 7" DIAMETER 48 GD222 TERMINAL ASSEMBL Y 4 9 BM67ADJ 30" T O 53" ADJUST ABLE PIPE - 7" DIA 5 0 W500-0077 .
22 W415-0098 / C / 04.19.06 15 63 53 43 9 8 * 7 6 36 A T T E N T I O N - C H A U D C A U T I O N - H O T 45 21 19 20 18 17 46 50 49 47 52 52 52 44 65 5 4 13 35 29 27 24 26 28 31 16 40 11 1 2 3 22 57 55 54 58 56 WARNING: This is a fast acting thermocouple.
23 W415-0098 / C / 04.19.06 Pilot will not light. - check if pilot can be lit by a match - check that the wire is connected to the push button ignitor . - check if the push button ignitor needs tightening. - replace the wire if the wire insulation is broken or frayed.
24 W415-0098 / C / 04.19.06 Main burner goes out; pilot goes out. REFER TO "MAIN BURNER GOES OUT ; PILOT ST A YS ON" Thermocouple shorting or faulty . V ent re-circulating (MODEL GDS50 ONL Y) - check joint seals and installation. - loosen and tighten thermocouple - clean thermocouple and valve connection.
An important point after buying a device Napoleon Fireplaces GDS 50-N (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Napoleon Fireplaces GDS 50-N yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Napoleon Fireplaces GDS 50-N - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Napoleon Fireplaces GDS 50-N you will learn all the available features of the product, as well as information on its operation. The information that you get Napoleon Fireplaces GDS 50-N will certainly help you make a decision on the purchase.
If you already are a holder of Napoleon Fireplaces GDS 50-N, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Napoleon Fireplaces GDS 50-N.
However, one of the most important roles played by the user manual is to help in solving problems with Napoleon Fireplaces GDS 50-N. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Napoleon Fireplaces GDS 50-N along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center