1 W415-0275 / C / 09.23.05 R-2000 CERTIFIED UNDER CANADIAN AND AMERICAN NA TIONAL ST ANDARDS, C SA 2.22, AND ANSI Z21.50 RESPECTIVEL Y FOR VENTED GAS FIREPLACES.
2 W415-0275 / C / 09.23.05 WARNING • The product is a vented gas fireplace. Do not burn wood or other materials in this fireplace. • Adults and especially children should be alerted to the hazards of high surface temperatures and should stay away to avoid burns or clothing ignition.
3 W415-0275 / C / 09.23.05 NAPOLEON products are manufactured under the strict Standard of the world recognized ISO 9001 : 2000 Quality Assurance Certificate. NAPOLEON products are designed with superior components and materials, assembled by trained craftsmen who take great pride in their work.
4 W415-0275 / C / 09.23.05 Minimum inlet gas supply pressure is 4.5 inches water column for natural gas and 11 inches water column for propane. Maximum inlet gas pressure is 7 inches water column for natural gas and 13 inches water column for propane.
5 W415-0275 / C / 09.23.05 This is a vented appliance and must be connected to a chimney in accordance with the current installation codes. In absence of local codes, install to the current National Fuel Gas Code, ANSI Z223.1, or the current CAN/CGA B149, Installation Codes.
6 W415-0275 / C / 09.23.05 P I P I L O T 3 1 2 N O L O T H I L O F F O It is best to frame your fireplace after it is positioned and the vent system is installed.
7 W415-0275 / C / 09.23.05 Combustible mantle clearance can vary according to the mantle depth. Use the graph to help evaluate the clear- ance needed. FIGURE 13 a FIGURE 13 b NAILING T AB FIGURE 1 1 1) Attach the nailing tabs to the corner posts using the 2 sheet metal screws sup- plied.
8 W415-0275 / C / 09.23.05 The upper louvres must be removed to allow the door to be opened or closed. To access the lower door latch, open the valve con- trol door. Release the top and bottom door latches, lo- cated at the right side of the door. UPPER L OUVRE S : Insert the upper louvres into the slots on both brackets.
9 W415-0275 / C / 09.23.05 4. Position the notch located on the end of the center log (#5) against the middle grate post with the other end of the log resting in the pocket of the left crossover log. 5. Place the bottom of the right crossover log (#6) against the right firebox side and pulled forward to the grate.
10 W415-0275 / C / 09.23.05 Attach the connectors from the black and white wires to the thermodisc and se- cure the thermodisc bracket to the securing stud at the bottom left of the unit using a lock washer and wing nut. Ensure that the thermodisc touches the firebox wall.
11 W415-0275 / C / 09.23.05 RECEPTACLE / JUNCTION BOX OPTIONAL THERMOSTATIC SENSOR SLOTS OPEN ENDED BRACKET VARIABLE SPEED/ PIEZO IGNITOR JUNCTION BOX THERMODISC SENSOR ASSEMBLY BRACKET RECEPTACLE / A.
12 W415-0275 / C / 09.23.05 FLAME ADJUSTMENT KNOB O T P I L L O I H T P I L O N O F F O PILOT ON/OFF KNOB • T urn off all gas to the fireplace. • O pen windows. • D o not try to light any appliance. • D o not touch any electric switch; do not use any phone in your building.
13 W415-0275 / C / 09.23.05 AIR SHUTTER ADJUSTMENT MUST ONLY BE DONE BY A QUALIFIED GAS INSTALLER! Air shutter is accessed beside gas valve. P I P I PILOT SCREW L O T N O L O T H I L O F F O Adjust the pilot screw to provide properly sized flame. Turn in a clockwise direction to reduce the gas flow.
14 W415-0275 / C / 09.23.05 # P AR T NO . DESCRIPTION 1 W357-0001 PIEZO IGNITER 2 W680-0004 THERMOPILE 3 W680-0005 THERMOCOUPLE 4 W010-0764 BURNER 5 W010-0800 NA TURAL GAS PILOT ASSEMBL Y 5 W010-0801 .
15 W415-0275 / C / 09.23.05.
16 W415-0275 / C / 09.23.05 Pilot will not light. - check if pilot can be lit by a match - check that the wire is connected to the push button ignitor. - check if the push button ignitor needs tightening. - replace the wire if the wire insulation is broken or frayed.
17 W415-0275 / C / 09.23.05 P I A B P I L O T N O L O T H I L O F F O White / grey film forms. Sulphur from fuel is being deposited on glass, logs or combustion chamber sur- faces. - clean the glass with a recommended gas fireplace glass cleaner. DO NOT CLEAN GLASS WHEN HO T.
18 W415-0275 / C / 09.23.05 Wol f Steel Fireplace Service History This fireplace must be serviced annually depending on usage. Date Service T echnician Name Service Performed Special Concerns Dealer N.
19 W415-0275 / C / 09.23.05 NO TES.
20 W415-0275 / C / 09.23.05 NO TES.
An important point after buying a device Napoleon Fireplaces BGNV36P (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Napoleon Fireplaces BGNV36P yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Napoleon Fireplaces BGNV36P - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Napoleon Fireplaces BGNV36P you will learn all the available features of the product, as well as information on its operation. The information that you get Napoleon Fireplaces BGNV36P will certainly help you make a decision on the purchase.
If you already are a holder of Napoleon Fireplaces BGNV36P, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Napoleon Fireplaces BGNV36P.
However, one of the most important roles played by the user manual is to help in solving problems with Napoleon Fireplaces BGNV36P. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Napoleon Fireplaces BGNV36P along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center