Instruction/ maintenance manual of the product BGD40-P Napoleon Fireplaces
Go to page of 36
1 W415-0299 / J / 04.14.08 W415-0299 / J / 04.14.08 $10.00.
2 W415-0299 / J / 04.14.08 Pg 3-5 INTRODUCTION W arranty General Instructions General Information Care of Glass & Plated Parts Dimensions 6-13 VENTING V ent Lengths Minimum Air T erminal Location .
3 W415-0299 / J / 04.14.08 NAPOLEON® products are manufactured under the strict Standard of the world recognized ISO 9001 : 2000 Quality Assurance Certifi cate. NAPOLEON® products are designed with superior components and materials, assembled by trained craftsmen who take great pride in their work.
4 W415-0299 / J / 04.14.08 THIS GAS FIREPLACE SHOULD BE INST ALLED AND SERVICED BY A QUALIFIED INST ALLER to conform with local codes. Installa- tion practices vary from region to region and it is imp.
5 W415-0299 / J / 04.14.08 DIMENSIONS SEE-THRU PENINSULA OPEN-END FIGURE 1a FIGURE 1b FIGURE 1c.
6 W415-0299 / J / 04.14.08 Use only Wolf Steel or Simpson Dura-V ent Model DV -GS, Selkirk Direct T emp or American Metal Amerivent venting components. Minimum and maximum vent lengths, for both horizontal and vertical installations, and air terminal loca- tions for either system are set out in this manual and must be adhered to.
7 W415-0299 / J / 04.14.08 MINIMUM AIR TERMINAL L OCA TION CLEARANCES FIGURE 2.
8 W415-0299 / J / 04.14.08 VENTING APPLICA TION FL O W CHART VER TICAL TERMINA TION HORIZONT AL TERMINA TION V ertical rise is equal to or great- er than the horizontal run Horizontal run + v er ti- c.
9 W415-0299 / J / 04.14.08 Use the GD401 periscope kit to locate the air termination above grade. The periscope must be installed so that when fi nal grading is completed, the bottom air slot is located a minimum of 12" above grade. When venting, the horizontal run must be kept to a maximum of 20 feet.
10 W415-0299 / J / 04.14.08 REQUIRED VERTICAL RISE IN FEET (V T ) CALCULA TED HORIZONT AL VENT RUN PLUS OFFSETS IN FEET (H T ) FIGURE 5 45º FIGURE 6 90° H 1 H 2 When (H T ) < (V T ) Simple ventin.
11 W415-0299 / J / 04.14.08 See graph to determine the required vertical rise V T for the required hori- zontal run H T . For vent confi gurations requiring more than one 45º and 90° elbow the following formulas apply: Formula 1: H T < 4.2 V T Formula 2: H T + V T < 24.
12 W415-0299 / J / 04.14.08 Example 3: V 1 = 5 ft V 2 = 10 ft V T = V 1 + V 2 = 5 + 10 = 15 ft H 1 = 3 ft H 2 = 2.5 ft H R = H 1 + H 2 = 3 + 2.5 = 5.5 ft H O = .03(one 45º elbow + three 90º elbows - 135º) = .03(45+90+90+90-135)=5.4 H T = H R + H O = 5.
13 W415-0299 / J / 04.14.08 For vent confi gurations requiring more than one 45º and one 90° elbow , the following formulas apply: F or mula 1: H T < 3V T F or mula 2: H T + V T < 40 feet Exa.
14 W415-0299 / J / 04.14.08 Refer to pages 6-13. All venting must have a minimum clear- ance of 2" to combustible material on the top and 1" to the sides and bottom.
15 W415-0299 / J / 04.14.08 Combustible materials may be installed fl ush with the front of the fi replace but must not cover any of the black face-areas of the fi replace. Non-combustible material (brick, stone or ceramic tile) may protrude in these areas.
16 W415-0299 / J / 04.14.08 Refer to pages 6-13. All venting must have a minimum clear- ance of 2" to combustible material on the top and 1" on the sides and bottom.
17 W415-0299 / J / 04.14.08 Refer to pages 6-13. All venting must have a minimum clear- ance of 2" to combustible material on the top and 1" to the sides and bottom.
18 W415-0299 / J / 04.14.08 There must be a minimum of 2" clearance to combustible ma- terial on the top and 2" to the sides and bottom when framing around all venting options. See pages 10-13. FIGURE 27a FIGURE 27b Horizontal V ent Off Fireplace V ertical Vent Of f Fireplace A = 43" using fl exible vent components.
19 W415-0299 / J / 04.14.08 FIGURE 33 FIGURE 31 INST ALLA TION WALL AND CEILING PR O TECTION HORIZONT AL INST ALLA TION VERTICAL INST ALLA TION FIGURE 32 FIGURE 29 Apply a bead of caulking all around and place the fi restop top, so that the vent shield covers the top of the vent within the opening.
20 W415-0299 / J / 04.14.08 F or safe and proper operation of the fi replace, follow the vent- ing instructions exactly. Eight (8") inches is the minimum bend radius allowed for the 8" diameter fl exible liner .
21 W415-0299 / J / 04.14.08 FIGURE 41 1. Install the 5" diameter fl ex pipe to the fi replace. Secure with 3 screws and fl at washers. Seal the joint and screw holes using high temp sealant (not supplied) or Red RTV Silicone may also be used in this location.
22 W415-0299 / J / 04.14.08 Combustible mantel clearance can vary according to the mantel depth. Use the graph to help evaluate the clearance needed. The three-sided top extension piece may be removed if non-combustible framing is faced with a non-combustible material.
23 W415-0299 / J / 04.14.08 PHAZER TM logs, glowing and charcoal embers, exclusive to Wolf Steel Ltd. fi replaces, provide a unique and realistic glowing effect that is dif ferent in every installation. T ake the time to carefully position the embers for a maximum glowing effect.
24 W415-0299 / J / 04.14.08 L36 LOUVRE INST ALLA TION FIGURE 52 a-c HOOD Attach the hood by pressing the top fl ange into the clips along the top of the louvre opening. Secure using a screw through the centre slot. LOWER LOUVRES Insert the hinge clips into the slots located at the bottom left and right corners of the unit.
25 W415-0299 / J / 04.14.08 Ensure that the door is proper ly clipped onto the steel lip to pre- v ent o verhea ting, glass breaka ge and / or discolora- tion of the upper trim. T o install the door(s), hook it over the steel lip located above the door opening.
26 W415-0299 / J / 04.14.08 Remove the "Z" shaped mounting bracket secured to the burner , by the pilot. Remove the thermodisc from the bracket supplied in the blower kit and attach to the mounting bracket. Attach the connectors from the black and white wires to the ther- modisc.
27 W415-0299 / J / 04.14.08 • T urn off all gas to the fi replace. • Open windows. • Do not try to light any appliance. • Do not touch any electric switch; do not use any phone in your building. • Immediately call your gas supplier from a neighbour's phone.
28 W415-0299 / J / 04.14.08 Adjust the pilot screw to provide properly sized fl ame. T urn in a clockwise direction to reduce the gas fl ow . Natural gas models have air shutters set at 1/4 (.250") inch open. Propane gas models have air shutters set at 7/16 (.
29 W415-0299 / J / 04.14.08 # P ART No. DESCRIPTION 1* W361-0016 GLOWING EMBERS 2* W550-0001 CHARCOAL EMBERS 3* W562-0009 DOOR GASKET (100") 4 W010-0454 GLASS W/ GASKET 5 W010-1778 FIRESTOP 6* W3.
30 W415-0299 / J / 04.14.08.
31 W415-0299 / J / 04.14.08 # P ART No. DESCRIPTION 1 W690-0001 MILLIVOL T THERMOST A T 2 GD501 HEA T GUARD 3* W573-0007 HI-TEMP SEALANT 4* W010-0370 WALL SUPPORT ASSEMBL Y 5 GZ-550-1KT BLOWER KIT 6* .
32 W415-0299 / J / 04.14.08 TR OUBLE SHOO TING GUIDE B EFORE A TTEMPTING TO TROUBLESHOOT , PURGE YOUR UNIT AND INITIALL Y LIGHT THE PILOT AND THE MAIN BURNER WITH THE GLASS DOOR OPEN . SYMPTOM PROBLEM TEST SOLUTION Main burner fl ame is a blue, lazy , transparent fl ame.
33 W415-0299 / J / 04.14.08 SYMPTOM PROBLEM TEST SOLUTION Pilot will not light. No spark at pilot burner - Check if pilot can be lit by a match - Check that the wire is connected to the push button igniter . - Check if the push button igniter needs tightening.
34 W415-0299 / J / 04.14.08 W olf Steel Fir eplace Ser vice Histor y This fireplace must be serviced annually depending on usage. Date Service T echnician Name Service Performed Special Concerns Deale.
35 W415-0299 / J / 04.14.08 NO TES.
36 W415-0299 / J / 04.14.08 NO TES.
An important point after buying a device Napoleon Fireplaces BGD40-P (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Napoleon Fireplaces BGD40-P yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Napoleon Fireplaces BGD40-P - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Napoleon Fireplaces BGD40-P you will learn all the available features of the product, as well as information on its operation. The information that you get Napoleon Fireplaces BGD40-P will certainly help you make a decision on the purchase.
If you already are a holder of Napoleon Fireplaces BGD40-P, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Napoleon Fireplaces BGD40-P.
However, one of the most important roles played by the user manual is to help in solving problems with Napoleon Fireplaces BGD40-P. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Napoleon Fireplaces BGD40-P along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center