Instruction/ maintenance manual of the product BGNV42N Napoleon
Go to page of 16
1 W415-0377 / 03.04.03 INST ALLER: THESE INSTRUCTIONS MUST BE CONVEYED TO AND REMAIN WITH THE HOMEOWNER. Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON L4M 4Y8 Canada • (705)721-1212 • fax(705)722-6031 www .napoleonfireplaces.com • ask@napoleon.on.
2 W415-0377 / 03.04.03 P G 2 - 4 INTRODUCTION Warranty General Instructions General Information Care of Glass & Plated Parts 5 VENTING V ent Safety Switch Hi Limit Switch V enting Action Check 6 -.
3 W415-0377 / 03.04.03 NAPOLEON gas fireplaces are manufactured under the strict Standard of the world recognized ISO 9001 : 2000 Quality Assurance Certificate. NAPOLEON products are designed with superior components and materials, assembled by trained craftsmen who take great pride in their work.
4 W415-0377 / 03.04.03 Do not use abrasive cleaners to clean plated parts. Buff lightly with a clean dry cloth. The fireplace is factory equipped with 3/16" thick tempered glass. Use only re- placement glass available from your Napoleon dealer . Do not substitute ma terials .
5 W415-0377 / 03.04.03 This is a vented appliance and must be connected to a chimney in accordance with the current installation codes. In absence of local codes, install to the current National Fuel Gas Code, ANSI Z223.1, or the current CAN/CGA B149, Installation Codes.
6 W415-0377 / 03.04.03 It is best to frame your fireplace after it is positioned. Use 2x4's and frame to local building codes. FIGURE 7-9. Note: In order to avoid the possibility of exposed insul.
7 W415-0377 / 03.04.03 NAILING TA B 1) Attach the nailing tabs to the corner post s using the 2 sheet metal screws supplied. Secure through the centre of the top and bottom slots in the nailing tab and then through the existing holes in the corner posts.
8 W415-0377 / 03.04.03 The upper louvres must be removed to allow the door to be removed. Release the two door latches, located across the top of the door and lift off the lower door bracket. Insert the upper louvres into the slots on both brackets. Attach each hinge on the lower louvre assembly to the lip of the fireplace base with 2 screws.
9 W415-0377 / 03.04.03 PHAZER TM logs and glowing embers, exclusive to Napo- leon Fireplaces, provide a unique and realistic glowing ef- fect that is different in every inst allation. T ake the time to carefully position the glowing embers for a maximum glow- ing effect.
10 W415-0377 / 03.04.03 Attach the connectors from the black and white wires to the thermodisc and secure the thermodisc bracket to the secur- ing stud at the bottom left of the unit using a lock washer and wing nut. Ensure that the thermodisc touches the firebox wall.
11 W415-0377 / 03.04.03 Attach and secure the sensor assembly bracket to the se- curing stud located next to the receptacle/junction box at the bottom left of the unit using the lock washer and wing nut. Ensure that the thermodisc touches the firebox wall.
12 W415-0377 / 03.04.03 • Turn off all gas to the fireplace. • Open windows. • Do not try to light any appliance. • Do not touch any electric switch; do not use any phone in your building. • Immediately call your gas supplier from a neighbour's phone.
13 W415-0377 / 03.04.03 Adjust the pilot screw to provide properly sized flame. Turn in a clockwise direction to reduce the gas flow . Closing the air shutter will cause a more yellow flame, but can lead to carboning. Opening the air shutter will cause a more blue flame, but can cause flame lifting from the burner ports.
14 W415-0377 / 03.04.03 # P ART N o . DESCRIPTION 2 5 GDL42K LOUVRE KIT - UPPER & LOWER - BLACK 2 5 GDL42PB LOUVRE KIT - UPPER & LOWER - POLISHED BRASS 2 5 GDL42SS LOUVRE KIT - UPPER & LOW.
15 W415-0377 / 03.04.03 Pilot will not light. - check if pilot can be lit by a match - check that the wire is connected to the push button ignitor . - check if the push button ignitor needs tightening. - replace the wire if the wire insulation is broken or frayed.
16 W415-0377 / 03.04.03 White / grey film forms. Sulphur from fuel is being deposited on glass, logs or combustion chamber sur- faces. - clean the glass with a recommended gas fireplace glass cleaner . DO NOT CLEAN GLASS WHEN HOT . If deposits are not cleaned off regularly , the glass may become permanently marked.
An important point after buying a device Napoleon BGNV42N (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Napoleon BGNV42N yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Napoleon BGNV42N - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Napoleon BGNV42N you will learn all the available features of the product, as well as information on its operation. The information that you get Napoleon BGNV42N will certainly help you make a decision on the purchase.
If you already are a holder of Napoleon BGNV42N, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Napoleon BGNV42N.
However, one of the most important roles played by the user manual is to help in solving problems with Napoleon BGNV42N. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Napoleon BGNV42N along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center