Instruction/ maintenance manual of the product BGNV40-N Napoleon
Go to page of 28
1 W415-0320 / D / 01.06.07 W415-0320 / D / 01.16.07.
2 W415-0320 / D / 01.06.07 WHA T T O DO IF Y OU SMELL GAS WARNINGS & SAFETY PRECA UTIONS.
3 W415-0320 / D / 01.06.07 Pg 2- 6 INTRODUCTION Warnings and Safety Precautions Warranty General Instructions General Information Care of Glass & Plated Parts Dimensions 7 VENTING V ent Safety Swi.
4 W415-0320 / D / 01.06.07 NAPOLEON gas fireplaces are manufactured under the strict Standard of the world recognized ISO 9001 : 2000 Quality Assurance Certificate. NAPOLEON products are designed with superior components and materials, assembled by trained craftsmen who take great pride in their work.
5 W415-0320 / D / 01.06.07 THIS GAS FIREPLACE SHOULD BE INST ALLED AND SERVICED BY A QUALIFIED INST ALLER to conform with local codes. Installation practices vary from region to re- gion and it is imp.
6 W415-0320 / D / 01.06.07 DIMENSIONS OPEN-END SEE-THRU PENINSULA ISLAND FIGURES 1a-d.
7 W415-0320 / D / 01.06.07 This is a vented appliance and must be connected to a chimney in accordance with the current installation codes. In absence of local codes, install to the current National Fuel Gas Code, ANSI Z223.1, or the current CAN/CGA B149, Installation Codes.
8 W415-0320 / D / 01.06.07 When finishing the fireplace, combustible material may rest directly on of the top extension. Note: Maximum weight tolerance is 400 lbs, provided that it is evenly distributed across the top extensions of the fire place.
9 W415-0320 / D / 01.06.07 FIGURE 1 1 DRYWALL 4" MIN DRYWALL Combustible materials may be installed flush with the front of the fireplace but must not cover any of the black face- areas of the fireplace. Non-combustible material (brick, stone or ceramic tile) may protrude in these areas.
10 W415-0320 / D / 01.06.07 Refer to page 7. Note: In order to avoid the possibility of exposed insula- tion or vapour barrier coming in contact with the fireplace body , it is recommended that the walls of the fireplace enclosure be “finished” (ie: drywall/sheetrock), as you would finish any other outside wall of a home.
11 W415-0320 / D / 01.06.07 DRYWALL DRYWALL 4" MIN FIGURE 17 Refer to page 7. Note: In order to avoid the possibility of exposed insula- tion or vapour barrier coming in contact with the fireplac.
12 W415-0320 / D / 01.06.07 FIGURE 20 DRYWALL DRYWALL Combustible materials may be installed flush with the front of the fireplace but must not cover any of the black face- areas of the fireplace. Non-combustible material (brick, stone or ceramic tile) may protrude in these areas.
13 W415-0320 / D / 01.06.07 Proceed once the vent installation is complete. 1. Move the fireplace into position and secure using the nailing tabs and/or secure to the floor through the 1/4"ø holes located at either end of the base. 2. Route a 3/8" N.
14 W415-0320 / D / 01.06.07 Combustible mantle clearance can vary according to the mantle depth. Use the graph to help evaluate the clearance needed. The three-sided top extension piece may be re- moved if non-combustible framing is faced with a non-com- bustible material.
15 W415-0320 / D / 01.06.07 PHAZER TM logs, glowing and charcoal embers, exclusive to Napoleon fireplaces, provide a unique and realistic glow- ing effect that is dif ferent in every installation. T ake the time to carefully position the embers for a maximum glowing effect.
16 W415-0320 / D / 01.06.07 SLOT TA B B L36 L OUVRE INST ALLA TION FIGURE 36 a-c HOOD Attach the hood by pressing the top flange into the clips along the top of the louvre opening. Secure using a screw through the centre slot. LOWER LOUVRES Insert the hinge clips into the slots located at the bottom left and right corners of the unit.
17 W415-0320 / D / 01.06.07 Ensure that the door is properly clipped onto the steel lip to pre- v ent o verhea t- ing, glass break- age and / or dis- colouration of the upper trim. T o install the door(s), hook it over the steel lip located above the door opening.
18 W415-0320 / D / 01.06.07 Remove the thermodisc bracket from the top of the firebox. Remove the thermodisc from the bracket supplied in the blower kit and install the thermodisc into the fireplace bracket. Then replace the bracket in the location it was removed.
19 W415-0320 / D / 01.06.07 not use any phone in your building. • Immediately call your gas supplier from a neighbour's phone. Follow the gas supplier's instructions.
20 W415-0320 / D / 01.06.07 Adjust the pilot screw to provide properly sized flame. Turn in a clockwise direction to reduce the gas flow . Closing the air shutter will cause a more yellow flame, but can lead to carboning. Opening the air shutter will cause a more blue flame, but can cause flame lifting from the burner ports.
21 W415-0320 / D / 01.06.07 Contact your dealer for questions concerning prices and availability of replacement parts. Normally all parts can be ordered through your Napoleon dealer or distributor .
22 W415-0320 / D / 01.06.07 * W ARNING: This is a fast acting thermocouple. It is an integral safety component. Replace only with a fast acting thermocouple supplied by Wolf S teel Ltd.
23 W415-0320 / D / 01.06.07 # P AR T No . DESCRIPTION 1* W690-0001 MILL IVOL T THERMOST A T 2* GZ-550-1KT BLOWER KIT 3 L36K LOUVRE KIT- UPPER & LOWER - BLACK 4 ELB40K END LOUVRE KIT- BLACK 5 HOIG-.
24 W415-0320 / D / 01.06.07 Pilot will not light. - check if pilot can be lit by a match - check that the wire is connected to the push button ignitor . - check if the push button ignitor needs tightening. - replace the wire if the wire insulation is broken or frayed.
25 W415-0320 / D / 01.06.07 White / grey film forms. Sulphur from fuel is being deposited on glass, logs or combustion chamber sur- faces. - clean the glass with a recommended gas fireplace glass cleaner . DO NOT CLEAN GLASS WHEN HOT . If deposits are not cleaned of f regularly , the glass may become permanently marked.
26 W415-0320 / D / 01.06.07 W olf Steel Fir eplace Ser vice Histor y This fireplace must be serviced annually depending on usage. Date Service T echnician Name Service Performed Special Concerns Deale.
NO TES.
28 W415-0320 / D / 01.06.07 NO TES.
An important point after buying a device Napoleon BGNV40-N (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Napoleon BGNV40-N yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Napoleon BGNV40-N - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Napoleon BGNV40-N you will learn all the available features of the product, as well as information on its operation. The information that you get Napoleon BGNV40-N will certainly help you make a decision on the purchase.
If you already are a holder of Napoleon BGNV40-N, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Napoleon BGNV40-N.
However, one of the most important roles played by the user manual is to help in solving problems with Napoleon BGNV40-N. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Napoleon BGNV40-N along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center