About, Software, T ools, Safety 3 Camera Left & Front 4 Camera Right & Back 5 Quick Specs 6 Power On, Camera RUN, Inching, Camera Display 7 Loading the Magazine 8 Mounting the Magazine 10 Chan.
ARRIFLEX 416 Quick Guide 05/2006, Page 2 This page is left blank intentionally ..
ARRIFLEX 416 Quick Guide 05/2006, Page 3 About, Software, T ools, Safety About the 416 Preliminary Quick Guide This Quick Guide (order number K5.40076.0) provides a short introduction to the ARRIFLEX 416. This guide does not replace the ARRIFLEX 416 User’ s Guide (K5.
ARRIFLEX 416 Quick Guide 05/2006, Page 4 Camera Left & Fr ont RUN PHASE NORM PS/CCU LOCK MODE SEL/ ∆ SET/ V DIMMER — + Image rotation knob T ape hook PL lens port (Super 16 only) Front 3/8 –.
ARRIFLEX 416 Quick Guide 05/2006, Page 5 Camera Right & Back ON/OFF RUN LCS LCS TCC LDD RF CHAN ZOOM FOCUS IRIS L R L R L R RDY RS RS RUN button MINI MONITOR connector REMOTE connector Power conne.
ARRIFLEX 416 Quick Guide 05/2006, Page 6 Quick Specs Fps range: 1 to 75 fps, for ward only , in 0.001 fps increments Mirror Shutter: 180º to 45º, manually adjustable Fixed settings at: 180º, 172.
ARRIFLEX 416 Quick Guide 05/2006, Page 7 1 . T otal film exposed (or take counter) Standard speed. 2. Programmed speed. 3 . T ake counter (or total film exposed) Supply voltage & (with OBB-2), batter y capacity/magazines left. 4. Timecode hours & minutes Timecode minutes & framerate 5.
ARRIFLEX 416 Quick Guide 05/2006, Page 8 Loading the 416 Magazine Note: The 416 magazine has its feed and take-up chambers on opposite sides to the SR 1, 2 & 3 magazines. Step 1: The Feed Side Load the unexposed film into the feed side in absolute darkness (darkroom or changing tent).
ARRIFLEX 416 Quick Guide 05/2006, Page 9 Loading the 416 Magazine • Set the loop length by pulling the film head away from you and align it with the loop mark on the bottom of the magazine (see picture above). Adjust the loop length by turning the take-up film core.
ARRIFLEX 416 Quick Guide 05/2006, Page 10 Mounting the Magazine • Insert the magazine throat into the magazine aper ture in the back of the camera body and slide the magazine for ward until it locks in place.
ARRIFLEX 416 Quick Guide 05/2006, Page 11 Changing Fps & Shutter Angle The NORM and PS/CCU buttons above the display select between preset Standard Speeds and user adjustable Programmable Speeds. Standard Speeds of 23.976, 24, 25, 29.97 & 30 fps are possible, while the Programmable Speed can be set anywhere from 1.
ARRIFLEX 416 Quick Guide 05/2006, Page 12 Beeper , Backlight & RGB ARRIGLOW Beeper The 416 is equipped with a beeper which can sound when the camera is started or stopped. The upper line of display mode 6 allows the user to decide whether and when the beeper sounds and how loud (LS is shown for ‘loudspeaker’).
ARRIFLEX 416 Quick Guide 05/2006, Page 13 On-board Batter y On-Board Batter y OBB-2 The OBB-2 On-Board Batter y attaches directly to the camera body by means of a quick change mechanism that can be easily operated with one hand.
ARRIFLEX 416 Quick Guide 05/2006, Page 14 MINI MONITOR connectors Integrated V ideo System Video out with data or Y–signal Clean Video out (no data) or C–signal Video lens IRIS Focus adjustment Fl.
ARRIFLEX 416 Quick Guide 05/2006, Page 15 Integrated V ideo System Automatic Gain Control • Press the MGC button to toggle between Manual Gain Control (LED on) and Automatic Gain Control (LED off). • When MGC is off, Automatic Gain Control will adjust the image brightness.
ARRIFLEX 416 Quick Guide 05/2006, Page 16 Accessories.
ARRIFLEX 416 Quick Guide 05/2006, Page 17 Accessories.
ARRIFLEX 416 Quick Guide 05/2006, Page 18 Note: T o write SMTPE timecode to film, ARRIFLEX 416 magazines must have the 416 Timecode Module fitted. Note: T imecode recording is only possible at the 5 Standard Speeds of 23.976, 24, 25, 29.97 & 30 fps.
ARRIFLEX 416 Quick Guide 05/2006, Page 19 Timecode Sensitivity T able 16 mm Kodak Film Stocks Kodak 7201 (Color Negative) TCS 7 Kodak 7205 (Color Negative) TCS 6 Kodak 7212 (Color Negative) TCS 6 Koda.
ARRIFLEX 416 Quick Guide 05/2006, Page 20 ARRI Gr oup Addresses Australia ARRI Australia PTY Limited (Sales, Ser vice & Rental) Unit 6C, 5 T alavera Road, Macquarie Park, Sydney . NSW 2113, Australia V oice phone: +61 (2) 9855 4300, F AX: +61 (2) 9855 4301 Email: info@arri.
An important point after buying a device ARRI 416 (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought ARRI 416 yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data ARRI 416 - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, ARRI 416 you will learn all the available features of the product, as well as information on its operation. The information that you get ARRI 416 will certainly help you make a decision on the purchase.
If you already are a holder of ARRI 416, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime ARRI 416.
However, one of the most important roles played by the user manual is to help in solving problems with ARRI 416. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device ARRI 416 along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center