Instruction/ maintenance manual of the product VFCS30DPV Monessen Hearth
Go to page of 32
ON OFF READ AND SA VE THESE INSTR UCTIONS This is an unv ented gas-fired heater . It uses air (o xygen) from the room in which it is installed. Pro visions f or adequate combustion and v entilation air must be pro vided.
2 58D6002 CONTENTS Important Safety Information .......................... 3 Product Features .............................................. 5 Dimensions ....................................................... 6 Getting Started .......................
58D6002 3 10. This unit complies with ANSI Z21.1 1.2 Unvented Heaters. 1 1. Do not install heater in a bathroom or bedroom unless approved for bedroom use.
4 58D6002 IMPOR T ANT SAFETY INFORMA TION Continued fr om page 3 16. Keep room area clear and free from comb ustible materi - als,gasolineandotherammablevaporsandliquids. 17. Unvented gas heaters are a supplemental zone heater .
58D6002 5 ON OFF ON OFF PR ODUCT FEA TURES Off/Pilot/On Knob Hi/Lo Knob Door Figure 1 - Cast Iron Sto ve (Single Door) Optional Remote Receiv er F an Switch Piezo Handle On/Off Switch Figure 2 - Cast .
6 58D6002 A C B DIMENSIONS Figure 3 - Dimensions CSVF20S/VFCS20D CSVF30S/VFCS30D A 21 1 / 4 " 26 3 / 4 " B 23" 28 1 / 2 " C 16 1 / 2 " 19 3 / 4 ".
58D6002 7 MAKE SURE Y OU HA VE RECEIVED ALL P ARTS: Carefully inspect the contents for shipping damage. If any parts are missing or damaged, immediately inform the dealer from whom you purchased the appliance.
8 58D6002 PR ODUCT SPECIFICA TIONS NA TURAL GAS NO TE: An external regulator is required to reduce supply pressure to a maximum of 10 1 / 2 " w .c. on Natural Gas systems operating at higher pressure . MILLIV OL T PRESSURE RegulatorPressureSetting: 3.
58D6002 9 CODES Adhere to all local codes or , in their absence, the latest edition of THE NA TIONAL FUEL GAS CODEANSI Z223.1 or NFP A54whichcanbeobtainedfrom… American National Standards Institute, Inc.
10 58D6002 ON OFF L 2 L 1 W H GENERAL INST ALLA TION INFORMA TION Thefollowingformulacanbeusedtodeterminethemaximumheaterratingperthedenitionofuncon.
58D6002 11 D Minimum to Either Side W all E Minimum A G G D Minimum to Either Side W all F Minimum F Minimum 36" in Front C B Mantel Clearance from T op of Unit Side, Measured from T op Rear Measured from Bac k Corner Measured From T op Corners Product Min.
12 58D6002 ON OFF A C B CLEARANCES / HEIGHT REQUIRMENTS Figure 6 - Placing Stove in Alco ve Note: Maintain minimum side and bac k clearances when placing sto ve in alcove.
58D6002 13 PILOT OFF REMOTE CONTROL LOGS ON OFF LOGS PILOT OFF REMOTE CONTROL LOGS REMO VING UNIT FR OM CRA TE 1. Removetwo(2)straps. See Figur e 7. 2. Open plastic bag and slide to bottom of unit . See Figur e 8.
14 58D6002 Pipe Coupling T o Heater V alve Gas Supply Inlet CONNECTING THE GAS NO TICE: A qualified gas appliance installer must connect the heater to the gas supply . Consult all local codes. IMPORT ANT : Holdheatervalvermlywithawrenchtopreventmovementwhenconnectingtoinletpipe.
58D6002 15 ON OFF CHECKING GAS PRESSURE and CONNECTING REMO TE RECEIVER MILLIV OL T CONTR OL (FIGURE 11) The valve regulatorcontrols the burner pressure whichshould becheckedatthepressuretestpoint.
16 58D6002 Label all wires prior to disconnection when servicing controls. Wiring error s can cause improper and danger ous operation. V erify pr oper operation after servicing. ELECTRICAL WIRING (MILLI-V OL T) Themilli-voltvalveisaself-poweredcombinationgascontrol THA T DOES NO T REQUIRE 110 V A C T O OPERA TE.
58D6002 17 PILOT OFF REMOTE CONTROL Left Bottom Log #2 Back Log #1 T op Left Log #4 LOG PLA CEMENT VF30 INST ALLING LOGS ON GRA TE (See Figure 14) 1. Installbacklog(#1)onrearlogsupportbracket.
18 58D6002 PILOT OFF REMOTE CONTROL VF20 INST ALLING LOGS ON GRA TE (See Figure 15) 1. Installbacklog(#1)onbackofburnerassembly . 2. Installfrontlog(#2)on2pegsonburnerassembly . R OCK WOOL INST ALLA TION (VF30 UNITS ONL Y) Figure 16 - Rock W ool Installation 1.
58D6002 19 Flames fr om the pilot, front and rear b urner should be visually checked as soon as the heater is installed. Inaddition,periodicallychecktheamesvisuallyduringoperation. CHECKING PILO T FLAME The pilot flame m ust alwa ys be present when the heater is in operation.
20 58D6002 PILOT OFF REMOTE CONTROL FLAME APPEARANCE CHECKING BURNER FLAME In normal operation at full rate after 15 minutes, the f ollowing flame appearances should be observed: Theleftandrightrearamesshould beyellowandextend1"-2"abovemiddlelogs.
58D6002 21 PILO T OFF REMOTE CO NTROL Figure 20 - Location of Piezo Ignitor , Contr ol Knobs and Switch on Milli-v olt Unit A. Thisappliance isequippedwithanignitiondevicewhichautomaticallylightsthepilot.Ifthe piezoisnot workingproperly ,see Match Lighting Instructions, page 24.
22 58D6002 O F F O N OPERA TING INSTRUCTIONS Figure 21 - Pilot T O TURN OFF GAS T O HEA TER 1. T urnON/OFFswitchtoOFFposition. 2. T urncontrolknobclockwise toOFFpositiontocompletelyshutofftheheater .
58D6002 23 1. Openstovedoor .Removeanyitemsnecessaryforeasyaccesstothepilot(forexample:logs,screens, etc.). 2. Follow appropriate lightinginstructions found previously .
24 58D6002 REPLA CEMENT P AR TS 3 4 5 6 7 8 9 10 2 12 1 1 1 BURNER ASSEMBL Y VF20 W ARNING Failure to position the par ts in accordance with these diagrams or failure to use only par ts specifically appro ved with this appliance may res ult in pr ope r ty dama g e or per sonal injury .
58D6002 25 REPLA CEMENT P AR TS LIST REPLA CEMENT P AR TS ARE A V AILABLE THROUGH Y OUR RET AILER. BURNER ASSEMBL Y VF20 Item Description Qty Natural Propane 1 Piezo Igniter 1 14D0503 14D0503 2 VF V a.
26 58D6002 3 4 5 6 7 8 9 10 1 1 12 1 13 14 15 2 REPLA CEMENT P AR TS BURNER ASSEMBL Y VF30 W ARNING Failure to position the par ts in accordance with these diagrams or failure to use only par ts specifically appro ved with this appliance may res ult in pr ope r ty dama g e or per sonal injury .
58D6002 27 REPLA CEMENT P AR TS LIST REPLA CEMENT P AR TS ARE A V AILABLE THROUGH Y OUR RET AILER. BURNER ASSEMBL Y Accessories Fle x Connector Flexcon 18 W all Switch Kit MVWS W all Ther mostat Kit W.
28 58D6002 1 2 3 4 5 REPLA CEMENT P AR TS ARE A V AILABLE THROUGH Y OUR RET AILER. Item Description Qty VF30 1 Back Log 1 58D1901 2 Bottom Left Log 1 58D1902 3 Bottom Right Log 1 58D1903 4 Left T op L.
58D6002 29 Note: All troub leshooting items are listed in order of operation. TR OUBLESHOO TING W ARNING W ARNING T urn appliance OFF and allo w to cool before servicing. Only a qualified service person should ser vice and repair the heater . SYMPT OM POSSIBLE CA USE A CTION When ignitor button is pressed, ther e is no spark at ODS/pilot.
30 58D6002 TR OUBLESHOO TING W ARNING If the gas quality is bad, your pilot ma y not sta y lit, the b urners may produce soot and the heater ma y backfire when lit. If the gas quality or pressure is low , contact your local gas supplier immediately .
58D6002 31 NOTE REGARDING VENTED PRODUCTS This product must be installed by a licensed plumber or gas tter when installed within the Commonwealth of Massachusetts. Anyresidencewitha directventproductmusthavea COdetector installed in the residence.
Marc h 2007 P/N 58D6002 • Rev . 5 LIMITED LIFETIME W ARRANTY MHS warrants its products to be free of defects in material and workmanship and backs each product with a Limited Lifetime W arranty .
An important point after buying a device Monessen Hearth VFCS30DPV (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Monessen Hearth VFCS30DPV yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Monessen Hearth VFCS30DPV - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Monessen Hearth VFCS30DPV you will learn all the available features of the product, as well as information on its operation. The information that you get Monessen Hearth VFCS30DPV will certainly help you make a decision on the purchase.
If you already are a holder of Monessen Hearth VFCS30DPV, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Monessen Hearth VFCS30DPV.
However, one of the most important roles played by the user manual is to help in solving problems with Monessen Hearth VFCS30DPV. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Monessen Hearth VFCS30DPV along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center