Instruction/ maintenance manual of the product CWC400 Monessen Hearth
Go to page of 24
For use in U.S./Canada Underwriter's Laboratories Report No. MH7603 87D1504 12/09 Rev .
2 CW C Series W oodbur ning Fireplace 87D1504 .
3 CW C Series W oodb ur ning Fir eplace 87D1504 50" (1270mm) 42" (1067mm) 35 Z v " (895mm) 46" (1 168mm) B, " (16mm) B, " (16mm) Zx " (13mm) Zx " 19 Cv " (.
4 CW C Series W oodb ur ning Fir eplace 87D1504 Insulation methods shown are optional for cold climate, not a requirement for unit operation. FPC554 Fireplace and chase parts identification.
5 CW C Series W oodb ur ning Fir eplace 87D1504 D RISE B G H B OFFSET C E 6 FT . G H A HEARTH FLOOR CHIMNEY SECTION CHIMNEY FLUE EXIT ELBOW FPC269 Chimney Requirements -typ.
6 CW C Series W oodb ur ning Fir eplace 87D1504 Preplanning an installation is very important to ensure safety and to save time and money . An installer must predetermine where a fireplace will be set and how the chimney system will be run.
7 CW C Series W oodb ur ning Fir eplace 87D1504 The chimney system is supported by the fireplace for vertical chimney heights less than 30' (9 m) above the hearth.
8 CW C Series W oodb ur ning Fir eplace 87D1504 Framing can be constructed before or after the fire- place is set in place, however , most installers build the frame before setting the fireplace. Frame fireplace with 2 x 4 lumber or heavier materials.
9 CW C Series W oodb ur ning Fir eplace 87D1504 Since you have already preplanned the chimney run, you should know exactly how the installation is to be accomplished - how much pipe is required, the number of elbows, if any , and type of termination to be used.
10 CW C Series W oodb ur ning Fir eplace 87D1504 Frame the ceiling chimney hole as shown in Figure 13. It is good practice to use framing lumber that is the same size as the ceiling joists; this is a requirement at attic level.
1 1 CW C Series W oodb ur ning Fir eplace 87D1504 An outside air kit is installed in all CWC Series Fire- places. If desired, or if local codes mandate the use of an air kit, then an AK-MST is required to complete the installation (from air kit to the outdoors).
12 CW C Series W oodb ur ning Fir eplace 87D1504 FP593 SR/C 11/20/97 Installing firestop spacer . FP593 Nails (4) Firestop Spacer Joist .
13 CW C Series W oodb ur ning Fir eplace 87D1504 Size of roof hole varies with the type of chimney ter- mination installed. Refer to installation instructions provided with the chimney termination to find correct size of roof hole.
14 CW C Series W oodb ur ning Fir eplace 87D1504 used below a flat mantel shelf, consult your local building codes for minimum clearance from top of fireplace open- ing to bottom of mantel shelf.
15 CW C Series W oodb ur ning Fir eplace 87D1504 1. Manville - CERAFORM 126, K=.27, 1/2 inches thick 2. MHSC - EH2416, K = .458, 1 inch thick required. A hearth extension is required to protect a combustible floor in front of the fireplace.
16 CW C Series W oodb ur ning Fir eplace 87D1504 COMMON MA TERIALS AND F ACTORS MA TERIAL K* R MINIMUM THICKNESS EH2416 Common Brick 0.458 5.0 1.09 0.50 in.** 0.10 5.46 in.** (MHSC) R V alue is for 1/2 inch. * Units of K = BTU/SQ FT/HR /˚F/IN ** Thickness of Listed Material FP533ADD Addendum 6/1/99 djt 8/4/99 changed .
17 CW C Series W oodb ur ning Fir eplace 87D1504 Only unvented gas log sets which have been found to comply with the Standard for Unvented Room Heaters, ANSI Z21.
18 CW C Series W oodb ur ning Fir eplace 87D1504 2-583 Parts page 3/2/99 djt 1 2 3 4 5 6 12 8 10 9 11 15 14a,b 17 16 18 OFF LOW 13 7 2 MHSC reserves the right to make changes in design, materials, specifications, prices and discontinue colors and products at any time, without notice.
19 CW C Series W oodb ur ning Fir eplace 87D1504 The following accessories for this appliance are available from your local distributor . Should you need additional information beyond what your distributor can furnish, contact: MHSC, 149 Cleveland Drive, Paris, KY 40361; Attn: T echnical Services.
20 CW C Series W oodb ur ning Fir eplace 87D1504 Round T op T ermination T op used to terminate chimney at roof. RL TSK8 (SK8) (Flashing not included.) Round T op T ermination - T op used to terminate chimney at chase.
21 CW C Series W oodb ur ning Fir eplace 87D1504 Square Chase T ermination Square chimney cap used to terminate chimney SL TS8 through chase.
22 CW C Series W oodb ur ning Fir eplace 87D1504.
23 CW C Series W oodb ur ning Fir eplace 87D1504 .
149 Cleveland Drive • Paris, Kentucky 40361 www .mhsc.com.
An important point after buying a device Monessen Hearth CWC400 (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Monessen Hearth CWC400 yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Monessen Hearth CWC400 - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Monessen Hearth CWC400 you will learn all the available features of the product, as well as information on its operation. The information that you get Monessen Hearth CWC400 will certainly help you make a decision on the purchase.
If you already are a holder of Monessen Hearth CWC400, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Monessen Hearth CWC400.
However, one of the most important roles played by the user manual is to help in solving problems with Monessen Hearth CWC400. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Monessen Hearth CWC400 along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center