Instruction/ maintenance manual of the product SEZ-A12 Mitsubishi Electronics
Go to page of 16
Air -Conditioner s SEZ-A12, A18, A24AR English INST ALLA TION MAN U AL For safe and correct use, please read this installation manual thoroughly before installing the air-conditioner unit.
2 Contents 1. Safety precautions ................................................................................... 2 2. Selecting the installation location ............................................................. 2 3. Installation diagram & Accessories .
3 3. Installation diagram & Accessories 3.1. Indoor unit (Fig. 3-1) 1 Air inlet (rear side) *Select the either back side or bottom side 2 Electrical par ts bo x 3 Suspension bolt pitch 5 Access door 6 Service space (It is necessar y to maintain a working service area from the ceiling.
4 AB 1 2 3 3. Installation diagram & Accessories Fig. 3-3 3.3. Checking the indoor unit accessories (Fig. 3-3) Check that the indoor unit is equipped with the f ollo wing parts and accessor ies: A.
5 5. Refrig erant piping w ork 5.1. Refrigerant pipe (Fig. 5-1) Maximum difference betw een heights of indoor unit and outdoor unit, the length of refrigerant piping and the number of bends in piping are within limits shown belo w . Models (A) Pipe length (B) Height (C) Number of (one wa y) difference bends (one way) SEZ-A12AR max.
6 a d c b ef 90 ° d c b a 5. Refrigerant piping work b a a b e b c d c A 5.2. Flaring work • Main cause of gas leakage is def ect in flaring work. Carry out correct flar ing w ork in the following procedure . 5.2.1. Pipe cutting (Fig. 5-3) • Using a pipe cutter cut the copper tube correctly .
7 5. Refrig erant piping w ork 5.4. Purging pr ocedures leak test PURGING PROCEDURES Connect the refrigerant pipes (both the liquid and gas pipes) between the indoor and the outdoor units. Remove the service port cap of the stop valv e on the side of the outdoor unit gas pipe .
8 7. Electrical work N A B H C F D E A G N 2 3 N 2 3 N L L 1 2 N B C F E N 2 3 12 N L L A H A D C E A G N 3 N F N L L (1) SEZ-A12AR (1:1 SYSTEM) 7.1. P ower supply (Fig.
9 7. Electrical work Fig. 7-4 LN N 2 3 N 2 3 1 2 5 12 7 6 3 4 65 mm 15 mm 1 2 Fig. 7-3 • P erform wiring as shown in the diagr am to the lower left. (Procure the cable lo- cally). (Fig. 7-3) Make sure to use cables of the correct polarity only . 1 Connecting cable 2 P ow er supply cable 4 core VVF cab le 3 core with ground IEC cord • SEZ-A12:1.
10 7.4. Outdoor unit (Fig. 7-8) • Connect cable from the indoor unit correctly on the terminal-bloc k. • Use the same terminal block and polarity as is used with the indoor unit. • For aftercare maintenance , giv e extr a length to connecting cable .
11 9. Air filter installation 9.1. Confirmation of enc losed par ts (Fig. 9-1) • Please ensure all the par ts sho wn below are present bef ore starting installation. 1 Filter × 1 2 Filter rail × 1 3 Filter rail × 1 4 ST . screw (4 × 10) × 14 5 Clamp × 2 6 Seal × 2 12 3 Fig.
12 9. Air filter installation 9.4. Filter installation points (Rear air intake) (Fig. 9-4) 1. Inser t the filter into rail 2 2. Hook the filter onto rail 3 A Control box B Drain pan D Filter E Rail 2 F Rail 3 Fig. 9-4 1 2 B A E D F Fig. 9-5 2 1 A E D F A F H G E 9.
13 10.1. Bef ore test run s After completing installation and the wiring and piping of the indoor and outdoor units, c heck f or refrigerant leakage, looseness in the power suppl y or control wiring, wr ong polarity , and no disconnection of one phase in the supply .
14 10.4. A UT O REST ART FUNCTION This model is equipped with the A UT O REST ART FUNCTION. When the indoor unit is controlled with the remote controller , the operation mode, set temperature , and the fan speed are memorized b y the indoor controller board.
15 1 Wiring from the Remote Control This wire is connected to terminal block f or remote controller of the indoor unit (non- polar). 2 When a Different Refrigerant System Grouping is Used. Up to 4 refrigerant systems can be controlled as one group using the MA remote controller .
Please be sure to put the contact address/telephone number on this manual before handing it to the customer. • Low Voltage Directive 73/23/ EEC • Electromagnetic Compatibility Directive 89/ 336/ EEC This product is designed and intended for use in the residential, commercial and light-industrial environment.
An important point after buying a device Mitsubishi Electronics SEZ-A12 (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Mitsubishi Electronics SEZ-A12 yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Mitsubishi Electronics SEZ-A12 - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Mitsubishi Electronics SEZ-A12 you will learn all the available features of the product, as well as information on its operation. The information that you get Mitsubishi Electronics SEZ-A12 will certainly help you make a decision on the purchase.
If you already are a holder of Mitsubishi Electronics SEZ-A12, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Mitsubishi Electronics SEZ-A12.
However, one of the most important roles played by the user manual is to help in solving problems with Mitsubishi Electronics SEZ-A12. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Mitsubishi Electronics SEZ-A12 along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center