Instruction/ maintenance manual of the product MUZ-D36NA Mitsubishi Electronics
Go to page of 44
SER VICE MANUAL CONTENTS 1. TECHNICAL CHANGES ··································· 3 2. P ART NAMES AND FUNCTIONS ····················· 3 3. SPECIFICA TION ················································ 4 4.
2.
3 3 1 TECHNICAL CHANGES MUZ-D30NA MUZ-D30NA - U1 MUZ-D36NA MUZ-D36NA - U1 MUY -D30NA MUY -D36NA 1. New model P ART NAMES AND FUNCTIONS 2 MUZ-D30NA MUY -D30NA Piping Air outlet Drain hose Drain outlet .
4 4 3 SPECIFICA TION Item Model MSZ-D30NA MSY -D30NA MSZ-D36NA MSY -D36NA Capacity Rated(Minimum~Maximum) Cooling 1 Btu/h 30,700 (9,800 ~ 30,700) 30,700 (9,800 ~ 30,700) 32,000/33,200 (9,800 ~ 32,000).
5 5 T est condition ARI Mode T est Indoor air condition Outdoor air condition Dry bulb (°F) Wet bulb (°F) Dry bulb (°F) W et bulb (°F) SEER (Cooling) "A" Cooling Steady State at rated co.
6 Open as a rule 20 inch or more if the front and both sides are open 4 inch or more / 8 inch or more if there are obstacles to both sides Open as a rule 20 inch or more if the back, both sides and top are open 14 in .
7 7 5 WIRING DIAGRAM MUZ-D30NA MUZ-D36NA.
8 8 MUY -D30NA MUY -D36NA.
9 9 6 REFRIGERANT SYSTEM DIAGRAM Unit:inch MUZ-D30NA MUZ-D36NA MUY -D30NA MUY -D36NA Outdoor heat exchanger Flared connection Defrost thermistor RT6 1 Service port Service port Discharge temperature t.
10 Max. length A Max. Height difference B Indoor unit Outdoor unit MAX. REFRIGERANT PIPING LENGTH and MAX. HEIGHT DIFFERENCE Model Refrigerant piping : ft. Piping size O.D : in. Max. Length A Max. Height difference B Gas Liquid MUZ-D30NA MUZ-D36NA MUY -D30NA MUY -D36NA 100 50 5/8 3/8 ADDITIONAL REFRIGERANT CHARGE (R410A:oz.
11 D ATA 7 MUZ-D30NA MUZ-D36NA MUY -D30NA MUY -D36NA 7-1. PERFORMANCE DA T A 1) COOLING CAP ACITY Model Indoor air Outdoor intake air DB temperature ( ˚ F) IWB 75 85 95 105 1 15 ( ˚ F) TC SHC TPC TC SHC TPC TC SHC TPC TC SHC TPC TC SHC TPC MUZ-D30NA 71 37.
12 12 7-2. PERFORMANCE CURVE 65 70 75 75 70 65 45 40 35 30 25 20 15 Indoor intake air DB temperature (°F ) = 848 CFM Airflow 15 25 35 45 55 Outdoor intake air WB temperature (°F) 4.
13 13 7-3. CONDENSING PRESSURE Cooling Data is based on the condition of indoor humidity 50 %. Air flow should be set to High speed. MUZ-D36NA (PSIG) Condensing pressure 86 80 75 70 68 70 75 80 85 90 .
75 70 65 75 70 65 (PSIG) (PSIG) Condensing pressure Outdoor ambient temperature 14 20 25 30 35 40 45 50 55 60 65 70 (°F) 200 500 480 460 440 420 400 380 360 340 320 300 280 260 240 220 Ind oor DB tem.
15 15 7-4. ST ANDARD OPERA TION DA T A Model MSZ-D30NA MSZ-D36NA MSY -D30NA MSY -D36NA Item Unit Cooling Heating Cooling Heating Cooling Cooling T otal Capacity Btu / h 30,700 32,600 32,000/33,200 35,200 30,700 33,200/34,000 SHF — 0.64 — 0.62 — 0.
16 7-5. CAP ACITY AND INPUT CORRECTION BY INVERTER OUTPUT FREQUENCY MUZ-D36NA Capacity correction factors Input correction factors Input correction factors Capacity correction factors Correction of Co.
17 7-6. TEST RUN OPERA TION (How to operate fixed-frequency operation) 1. Press EMERGENCY OPERA TION switch to COOL or HEA T mode (COOL : Press once, HEA T : Press twice). 2. T est run operation starts and continues to operate for 30 minutes. 3. Compressor operates at rated frequency in COOL mode or 58 Hz in HEA T mode.
18 8 ACTUA TOR CONTROL MUZ-D30NA MUZ-D36NA MUY -D30NA MUY -D36NA 8-3. Relation between main sensor and actuator Sensor Purpose Actuator Compressor LEV Outdoor fan motor R.
19 SER VICE FUNCTIONS 9 MUZ-D30NA MUZ-D36NA MUY -D30NA MUY -D36NA 9-1. PRE-HEA T CONTROL If moisture gets into the refrigerant cycle, or when refrigerant is lique fi ed and col- lected in the compressor , it may interfere the start-up of the compressor .
20 10 TROUBLESHOOTING 10-1. CAUTIONS ON TROUBLESHOOTING 1. Before troubleshooting, check the following 1) Check the power supply voltage. 2) Check the indoor/outdoor connecting wire for miswiring.
21 Outline of the function This air conditioner can memorize the abnormal condition which has occurred once. Even though LED indication listed on the troubleshooting check table (10-3.
22 Does left lamp of OPERA TION INDICA TOR lamp on the indoor unit blink at the interval of 0.5 seconds? Blinks: The outdoor unit is abnormal. Beep is emitted at the same timing as the blinking of the left lamp of OPERA TION INDICA TOR lamp. 2 Ye s (Blinks ) No (OFF) The outdoor unit might be abnormal.
23 3. Outdoor unit failure mode table MUZ-D30NA MUZ-D36NA MUY -D30NA MUY -D36NA The left lamp of OPERA- TION INDICA TOR lamp (Indoor unit) Abnormal point (Failure mode / protection) LED indication (Outdoor P .
24 The left lamp of OPERA- TION INDICA TOR lamp (Indoor unit) Abnormal point (Failure mode / protection) LED indication (Out- door P .C. board) Condition Correspondence Indoor/outdoor unit failure mode recall function LED 1 LED 2 1 1-time fl ash Converter 5 times Goes out A failure is detected in the operation of the converter dur- ing operation.
25 The flashing frequency shows the number of times the LED blinks after every 2.5-second OFF . (Example) When the flashing frequency is “2”. ON OFF 2.5-second OFF 2.5-second OFF 0.5-second ON 0.5-second ON Outdoor electronic control P .C. board(Parts side) Lighting LED2 LED1 10-3.
26 No. Symptom Indication Abnormal point / Condition Condition Correspondence LED1 (Red) LED2 (Y ellow) 20 Outdoor unit oper- ates. Once Lighting Primary current protection The input current exceeds 15 A. These symptoms do not mean any abnormality of the product, but check the following points.
27 10-4. TROUBLE CRITERION OF MAIN P ARTS MUZ-D30NA MUZ-D36NA MUY -D30NA MUY -D36NA Part name Check method and criterion Figure Defrost thermistor (RT61) ( MUZ ) Ambient temperature thermistor (RT65) Outdoor heat ex- changer temperature thermistor (RT68) Measure the resistance with a tester .
28 OPERA TION / INDICA TOR lamp flashes 5-times. Outdoor unit does not operate. 10-5. TROUBLESHOOTING FLOW Measure the voltage between each lead wire leading to the compressor . U (BLK) - V (WHT) V (WHT) - W (RED) W (RED) - U (BLK) Is voltage output on right table? Ye s No Disconnect the terminal of the compressor .
29 OPERA TION INDICA TOR lamp flashes 6-times. Thermistor is abnormal. Thermistor Symbol Connector , Pin No. Board Defrost ( MUZ ) RT61 Between CN661 pin1 and pin2 Outdoor electronic control P .
30 Heating operation does not work. • Is there voltage of 208 / 230 V AC between pin1 and pin 2 at connector CN912? Ye s No Disconnect the lead wire leading to the compressor . 3 minutes after turning on the power supply , start EMERGENCY OPERA TION in HEA T mode.
31 Fan motor does not operate or stops operating shortly after starting the operation. Is the resistance between each ter- minal of outdoor fan motor normal? (Refer to 10-4.) Check the connection between the connector CN931 and CN932. Disconnect CN932 from outdoor electronic control P .
32 G Check of LEV When cooling, heat exchanger of non-operating indoor unit frosts. When heating, non-operating indoor unit gets warm. T urn ON power supply to the outdoor unit after checking LEV coil is mounted to the LEV body securely .
33 • Unit cannot operate neither by the remote controller nor by EMERGENCY OPERA TION switch. Indoor unit does not operate. • OPERA TION INDICA TOR lamp flashes ON and OFF in every 0.5 seconds. Outdoor unit doesn’t operate. Outdoor electronic control P .
34 1. Disconnect the connector CN681 in the electronic control P .C. board. 2. Check the resistance of HPS 1 minute after the outdoor unit power supply was turned OFF . Check the resistance between each terminal. Is HPS protection displayed immediately after compressor starts? Replace HPS.
35 J Electromagnetic noise enters into TV sets or radios Ye s Is the unit grounded? No Ground the unit. Ye s Is the distance between the antennas and the indoor unit within 9.91 ft., or is the distance between the antennas and the outdoor unit within 9.
36 -4 14 32 50 68 86 104 100 90 80 70 60 50 40 30 20 10 0 32 50 68 86 104 122 140 158 176 200 180 160 140 120 100 80 60 40 20 0 Resistance (k Ω ) Resistance (k Ω ) T emperature (°F) T emperature (.
37 MUZ-D30NA MUZ-D36NA MUY -D30NA MUY -D36NA 2. Noise filter P .C. board { MUZ CN912 R.V . coil 208 / 230 V AC 60 Hz Output 208 / 230 V AC 60 Hz Input 208 / 230 V AC 60 Hz Output F64 FUSE 2 A / 250 V CN902 T o power board { CN903 T o power board { CN61 NR64 V ARISTOR { CN901 T o electronic control P .
38 MUZ-D30NA MUZ-D36NA MUY -D30NA MUY -D36NA 3. Outdoor power board 294-370 VDC Output Connect to the compressor V oltage among phases: 180 V Connect to the earth CN5 Primary current detection (Connect to the noise filter) CN2 Connect to the controller board (+)1-5(–): Signal transmission (T o electronic control P .
39 OPERA TING PROCEDURE PHOTOS 1. Removing the cabinet (1) Remove the screws of the service panel. (2) Remove the screws of the top panel. (3) Remove the screw of the valve cover . (4) Remove the service panel. (5) Remove the top panel. (6) Remove the valve cover .
40 OPERA TING PROCEDURE PHOT OS 2. Removing the inverter assembly , P .C. board and power board (1) Remove the top panel, cabinet, service panel and the back panel.
41 OPERA TING PROCEDURE PHOT OS 4. Removing the defrost thermistor (MUZ), discharge temperature thermistor , outdoor heat exchanger temperature thermistor and ambient temperature thermistor (1) Remove the top panel, cabinet, service panel and the back panel.
42 OPERA TING PROCEDURE PHOT OS 6. Removing the compressor and 4-way valve (1) Remove the top panel, cabinet, service panel and the back panel. (Refer to 1.) (2) Remove the inverter assembly . (Refer to 2.) (3) Remove the R.V . coil. (Refer to 3.) (4) Recover gas from the refrigerant circuit.
43.
HEAD OFFICE: TOKYO BLDG., 2-7-3, MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310, JAP AN Copyright 2008 MITSUBISHI ELECTRIC ENGINEERING CO.,L TD Distributed in Feb. 2008. No. OBH502 7 Made in Japan New publication, effective Feb. 2008 Specifications subject to change without notice.
An important point after buying a device Mitsubishi Electronics MUZ-D36NA (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Mitsubishi Electronics MUZ-D36NA yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Mitsubishi Electronics MUZ-D36NA - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Mitsubishi Electronics MUZ-D36NA you will learn all the available features of the product, as well as information on its operation. The information that you get Mitsubishi Electronics MUZ-D36NA will certainly help you make a decision on the purchase.
If you already are a holder of Mitsubishi Electronics MUZ-D36NA, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Mitsubishi Electronics MUZ-D36NA.
However, one of the most important roles played by the user manual is to help in solving problems with Mitsubishi Electronics MUZ-D36NA. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Mitsubishi Electronics MUZ-D36NA along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center