Instruction/ maintenance manual of the product KALEIDO-K2 Miranda Camera Co
Go to page of 32
K aleido-K2 High Resolution Vir tual Monit or W all Pr oc essor Guide to Installation and Operation M406-9900-402 Copyright 2006 Miranda T echnologies Inc. Specifications may be subject to change. Printed in Canada November 2006 K aleido-K2 Mirand a T echnologies inc.
GUIDE TO INSTALLATION AND OPERATION Kaleido K2 Safety Compliance Information Safety Compliance This equipment complies w ith: - CSA C22.2 No. 60950-1-03 / Safet y of Information Techno logy Equipment, Including El e ctrical Business Equipment.
GUIDE TO INSTALLATION AND OPERATION Kaleido K2 Contents 1 Kaleido-K2 High Resolution Virtual Monitor Wall Processor .................................................................... 1 1.1 Intr oduction ..............................................
GUIDE TO INSTALLATION AND OPERATION Kaleido K2.
GUIDE TO INSTALLATION AND OPERATION Kaleido K2 | 1 1 Kaleido-K2 Ultra High Resoluti on Virtual Monitor Wall Processor 1.1 Introduction The Kaleido-K2 Ultra High Resolution V irtual Monito r Wall Proc essor is designed as the ultimate solution to s ignal monitoring requirement s.
GUIDE TO INSTALLATION AND OPERATION 2 | Kaleido K2 Figure 1.2.1 Kale ido-K2 functional block dia gram REF Input.
GUIDE TO INSTALLATION AND OPERATION Kaleido K2 | 3 2 Overview 2.1 Front Panel The front panel of the Kaleido-K2 has three operationa l elements: - ON/OFF pushbutton - System status indicator L E D - CPU reset button. These items are actually located on the front edge of t he controller card.
GUIDE TO INSTALLATION AND OPERATION 4 | Kaleido K2 3 Mechanical Installation 3.1 Unpacking Make sure the following items have be e n shipped with y our Kaleido.
GUIDE TO INSTALLATION AND OPERATION Kaleido K2 | 5 Figure 3.2.2 Movin g the connecto r Once the DE-9 connector is installed in the prop er opening a nd the unit reassembled, do the following: - Remove the 4 rubber feet on the underside of the unit. - Place the Kaleido-RCP into the mounting bracket and secure it using the supplied screws (figure 3.
GUIDE TO INSTALLATION AND OPERATION 6 | Kaleido K2 4 Frame and Electri cal Installation Kaleido is a self-contained unit consisting of a frame, redundant po wer supplies, a controller card, and va rio us input and output cards. 4.1 Frame The frame is 4 RU high.
GUIDE TO INSTALLATION AND OPERATION Kaleido K2 | 7 4.2.2 Operation Connect each power supply to a power source usi ng the supplied power cords. In normal operation, both supplies should be switched ON (power switch on the power supply unit set to | ).
GUIDE TO INSTALLATION AND OPERATION 8 | Kaleido K2 4.3.1 Connector panel installation Remove the blank panel (a blank pan el is used to occ upy the rear panel space behin d empty slots) or existing connector panel. Release the captive screws at the to p and bottom, and pull the panel straight out of the frame.
GUIDE TO INSTALLATION AND OPERATION Kaleido K2 | 9 The location of the connectors differs between input a nd output cards, so placi ng the wrong type of card in a slot is simply not possible.
GUIDE TO INSTALLATION AND OPERATION 10 | Kaleido K2 The rear connector pan el (11) associated with the Controller module has the foll owing connectors: Ethernet: RJ-45 connecto r Ethernet interface for connection to LAN/WAN networks usin g TCP -IP. RS-422/485: DE-9S connector For connecting the Kaleido-RCP or other remot e cont rol devices.
GUIDE TO INSTALLATION AND OPERATION Kaleido K2 | 11 Green indicates that the unit is properly power ed and that one or both power su pplie s are on. Red indicates a stand-by mode: the unit is plug ged in but the Controller is not switched o n.
GUIDE TO INSTALLATION AND OPERATION 12 | Kaleido K2 4.4.2 GPI Module The GPI module provides interfaces and processin g to support 66 contact closure tally inputs and 36 contact closure alarm outputs. Four DC-37S con necto rs are in stalled on the MWR-GPI rear connector panel (10 ).
GUIDE TO INSTALLATION AND OPERATION Kaleido K2 | 13 GPI inputs characteristics: Signal: 64 short-to-ground inputs Connecto r: DC-37S GPI outputs characteristics: Signal: 66 opto-isolated co ntact closures Connecto r: DC-37S Characte ristics: Max differential voltage: 12 VDC Max s ink current: 70 mA Isolation voltage: 2500 VRMS Figure 4.
GUIDE TO INSTALLATION AND OPERATION 14 | Kaleido K2 4.4.3 Analog Audio Input Module (MWI-S A) This module provides inpu t s for 16 chan nels of analog stereo audio. Two DS UB 50 connectors are avail abl e on the MWR-SA rear connection panel (8). Figure 4.
GUIDE TO INSTALLATION AND OPERATION Kaleido K2 | 15 4.4.4 Digital Audio Input Module (MWI-AES ) This module provides inputs for 16 channels of AES/EBU digi tal audio. A single DSUB 50 connector is available on the MWR-AES rear conne ction pa nel (9 ).
GUIDE TO INSTALLATION AND OPERATION 16 | Kaleido K2 Figure 4.4.5.1 MWI-CVBS rear connector panel 4.4.6 Y/C Analog Video I nput Module (MWI-YC) This module provides inpu t s for 4 ch annels of Y/C (S -video) analog video. The inputs are mini-DIN 4-pin connectors, internally terminated and available on the MWR-YC rear connection module (5).
GUIDE TO INSTALLATION AND OPERATION Kaleido K2 | 17 Figure 4.4.7.3 MWA-BOC cable adapter 4.4.8 Digital Video SD-SDI Input Module (M WI-SDI ) This module provides inpu t s for four cha nnels of serial digital video. The inputs are on BNC connectors and are available on the MWR-4B rear connecti on module (2).
GUIDE TO INSTALLATION AND OPERATION 18 | Kaleido K2 Figure 4.4.8.2 DE-1 5P connector pinout 4.4.10 HD-SDI Video Input Module (MWI-HD) This module provides three standard - and high-definition digital video inputs.
GUIDE TO INSTALLATION AND OPERATION Kaleido K2 | 19 Figure 4.4.11.2 Audio mo nitoring connector pinout MON OUT: Provision for Monitoring output in SDI or Composite. Two slots are provided in the frame fo r the installation of output modules, increasing the flexibility of output management.
GUIDE TO INSTALLATION AND OPERATION 20 | Kaleido K2 Figure 4.5.1 Cascadin g two Kaleido-K2s Figure 4.5.1.1 Controlling multiple Kale ido-K2s through an ethe rnet network.
GUIDE TO INSTALLATION AND OPERATION Kaleido K2 | 21 4.5.2 Controlling multiple Kaleido-K 2s using RS-42 2 with a Kaleido-RCP Using the RS-422 comm unication port also allows up to 99 daisy-chained Kalei do -K2 frames to be controlled using only one Kaleido-RCP.
GUIDE TO INSTALLATION AND OPERATION 22 | Kaleido K2 5 Operation The function of Kaleido-K2 is to gather information from multiple sources and merge it into a single inform ation stream for presentation on a monitor. This process is managed un der softwa re control.
GUIDE TO INSTALLATION AND OPERATION Kaleido K2 | 23 6 Maintenance 6.1 Cleaning the air filter Occasionally, the air filter has to be removed and properly cleaned i n order to maintain proper ventilation. To remove and clean the air filter, follow these directions: 1.
GUIDE TO INSTALLATION AND OPERATION 24 | Kaleido K2 5. Remove the 4 screws that hold the fan onto the bracket, t hen remove the fan. 6. Install the new fan using the 4 retaining screws. 7. Plug in the fan power connector. Reinsta ll the fan bracket and the con nector panels.
GUIDE TO INSTALLATION AND OPERATION Kaleido K2 | 25 7 Specifications INPUT COMPOSITE VIDEO INPUT (MWI-CVB S) SIGNAL (4): NTSC (SMPTE 170M), PAL, PAL-M, PAL-NITU 624-4, SECAM RETURN LOSS: > 35 dB up to 5.
GUIDE TO INSTALLATION AND OPERATION 26 | Kaleido K2 SCALES: EBU DIGITAL PPM (IEC-6026 8-18), NORDIC (IEC-60268-10 TYPE I), BBC/UK PPM(IEC-60268-10 TYPE IIA), EBU PPM (IEC-60268-10 TYPE IIB) PROGRESSIV.
GUIDE TO INSTALLATION AND OPERATION Kaleido K2 | 27 OUTPUT PROGRESSIVE RGBHV OUTPUT 1 (MWO-HR) SIGNAL: Analog RGBHV RESOLUTION: From 800 x 600 to 1600 X 1200 NI H FREQUENCY: 31 kHz to 96 kHz REFRESH RATE: 50/59.94 Hz CABLE LENGH: 5m (low), 20m (medium) and 50m (hig h) cables built-in equalize r (Belden 1694) LEVEL: Selectable 0.
GUIDE TO INSTALLATION AND OPERATION 28 | Kaleido K2 REMOTE PORT (MWA-CPU) DESCRIPTION: Remote control panel communication port SIGNAL: RS-422 (SMPTE 207M, EBU-3245), RS-485 with 12V supply on pin 5 CONNECTOR: DE-9S (female) ETHERNET PORT(MWA-CPU) SIGNAL: 10/100 BASE-T (IEEE 802.
An important point after buying a device Miranda Camera Co KALEIDO-K2 (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Miranda Camera Co KALEIDO-K2 yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Miranda Camera Co KALEIDO-K2 - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Miranda Camera Co KALEIDO-K2 you will learn all the available features of the product, as well as information on its operation. The information that you get Miranda Camera Co KALEIDO-K2 will certainly help you make a decision on the purchase.
If you already are a holder of Miranda Camera Co KALEIDO-K2, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Miranda Camera Co KALEIDO-K2.
However, one of the most important roles played by the user manual is to help in solving problems with Miranda Camera Co KALEIDO-K2. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Miranda Camera Co KALEIDO-K2 along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center