Instruction/ maintenance manual of the product DS-75S16 Miller Electric
Go to page of 48
DS-75S12, DS-75S16, DS-75D12, and DS-75D16 OM-230 300A 2006 − 09 Processes Description MIG (GMA W) W elding Flux Cored (FCA W ) Welding (Gas-and Self-Shielding) Submerged (SAW) W elding Wire Feeder (Use with CV Power Sources) DS-75S/D Swingarc ™ File: MIG (GMA W) V isit our website at www.
Miller Electric manufactures a full line of welders and welding related equipment. For information on other quality Miller products, contact your local Miller distributor to receive the latest full line catalog or individual specification sheets. T o locate your nearest distributor or service agency call 1-800-4-A-Miller , or visit us at www .
T ABLE OF CONTENTS SECTION 1 − SAFETY PRECAUTIONS - READ BEFORE USING 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1. Symbol Usage 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
.
OM-230 300 Page 1 SECTION 1 − SAFETY PRECAUTIONS - READ BEFORE USING som _3/05 Y W arning: Protect yourself and others from injury — read and follow these precautions. 1-1. Symbol Usage Means W arning! W atch Out! There are possible hazards with this procedure! The possible hazards are shown in the adjoining symbols.
OM-230 300 Page 2 Arc rays from the w elding process produce intense visible and invisible (ultraviolet and infrared) rays that can burn eyes and skin.
OM-230 300 Page 3 1-3. Additional Symbols For Installation, Operation, And Maintenance FIRE OR EXPLOSION hazard. D Do not install or place unit on, over , or near combustible surfaces. D Do not install unit near flammables. D Do not overload building wiring − be sure power supply system is properly sized, rated, and protected to handle this unit.
OM-230 300 Page 4 1-5. Principal Safety Standards Safety i n W elding, Cutting, and Allied Processes, ANSI Standard Z49.1, from Global Engineering Documents (phone: 1-877-413-5184, website: www .
OM-230 300 Pa ge 5 SECTION 2 − CONSIGNES DE SÉCURITÉ − LIRE A V ANT UTILISA TION som _3/05 Y A vertissement : se protéger et protéger les autres contre le risque de blessure — lire et respecter ces consignes.
OM-230 300 Page 6 Le rayonnement de l’arc du procédé de soudage génère des rayons visibles et invisibles intenses (ultraviolets et infrarouges) susceptibles de provo- quer des brûlures dans les yeux et sur la peau. Des étincelles sont projetées pendant le soudage.
OM-230 300 Pa ge 7 2-3 . Da ngers suppléme ntaires en r el ation avec l’ins tallation, le f onctionnem ent et l a maintena nce Risque D’INCENDIE OU D’EXPLO- SION. D Ne pas placer l’appareil sur , au-dessus ou à proximité de surfaces inflammables.
OM-230 300 Page 8 2-5. Princi pales no rmes de sécurit é Safety in W elding, Cutting, and Allied Processes, ANSI Standard Z49.1, de Global Engineering Documents (téléphone : 1-877-413-5184, site In- ternet : www .
OM-230 300 Page 9 SECTION 3 − INTRODUCTION 3-1. Specifications T ype of Input Power W elding Power Source T ype Wire Feed Speed Range Wire Diameter Range W elding Circuit Rating W eight 24 V olts AC Single-Phase 10 Amperes 50/60 Hertz Constant V oltage (CV) DC With 14-Pin that provides voltage and current feedback Standard: 50 T o 1400 ipm (1.
OM-230 300 Page 10 4-2. Installing Control Box And Adjusting T ilt 1 W e ld Control 2 Bracket 3 Screw Bracket and screws are installed onto bottom of control at factory . 4 Swivel Loosen screws. Place control on swivel and slide forward. Tighten screws.
OM-230 300 Page 1 1 4-4. Installing Wire Guide Extension ST-152 383 1 Wire Guide Fitting 2 Bolt 3 Monocoil Liner 4 Wire Guide Extension T ighten bolt to secure liner in wire guide fitting. Do not overtighten bolt and crush liner . Repeat procedure for opposite side.
OM-230 300 Page 12 804 784-A Y T urn Off wire feeder and welding power source. Stop engine on welding generator . Y Use only with CC/CV DC Power Sources.
OM-230 300 Page 13 Ref. 803 187 1 Interconnecting Cables 2 Interconnecting Cable Receptacles 3 14-Pin Cord 4-7. Control Box Connections 1 3 2 4-8. 14-Pin Plug Information Pin* Pin Information A 24 volts ac with respect to socket G. A J K B Contact closure to A completes 24 volts ac contactor control circuit.
OM-230 300 Page 14 4-9. Removing Safety Collar And Adjusting Boom ST-142 599-C 1 Locking Knob T ighten knob to prevent boom movement. Loosen knob to allow boom movement. Change knob po- sition to limit upward movement. Pull boom down slightly and re- move safety collar .
OM-230 300 Page 15 1 2 4 3 4-12. Installing Drive Rolls 804 737-A 1 Drive Roll Carrier 2 Ejector Button 3 Drive Roll 4 Pressure Door Assembly Installation Open pressure door assembly . Lift drive roll swing arm. Align drive roll slots with three lobes on drive roll carrier .
OM-230 300 Page 16 4-13. Installing PD Continuous Wire Guides Ref. 804 731-A . PD Continuous Wire Guides: Should be used with .068/.072 in (1.8 mm) and smaller diameter wire for optimal performance. Should be used with PD drive rolls and cannot be used with non-PD (old- style) drive rolls.
OM-230 300 Page 17 4-14. Installing Non-PD (Old Style) Wire Guides Ref. 804 732-A Installing wire guides with non- PD (old- style) drive rolls . Non-PD (old-style) wire guides and drive rolls should be used with 5/64 in (2.0 mm) and larger diameter wire.
OM-230 300 Page 18 4-15. Installing W elding Gun 804 730-A 1 Gun Locking T ab 2 Power Clamp Knob 3 Power Pin Groove 4 Gun Connection End Installing gun with Accu-Mate connec- tion Loosen power clamp knob to allow power pin of gun to clear the gun locking tab.
OM-230 300 Page 19 4-16. Installing Welding Wire And Adjusting Pressure Drive Setting NONCONDUCTIVE SURF ACE NONCONDUCTIVE SURF ACE No Wire Slip Wire Slips T ools Needed: 15/16 in Ref.
OM-230 300 Page 20 4-17. Setting Internal DIP Switches On Motor Boards Remove wrapper . 1 DIP Switch S1 On Motor Boards PC1 and PC101. S1-1 Run-In enable or disable. S1-2 Automatic Run-In versus Manual Adjustment Run-in. Install wrapper when finished.
OM-230 300 Page 21 T ools Needed: 1/4 in 4-18. Equipment DIP Switch Settings (For Models With Meters Only) Ref. 803 154 / 803 188 Remove wrapper . 1 DIP Switch S2 On Digital Meter Board PC60 Install wrapper when finished.
OM-230 300 Page 22 SECTION 5 − OPERA TION 5-1. Power Switch 1 Power Switch 1 Ref. 803 183 1 Left/Right Select Switch Pressing the Left/Right Select switch allows the operator to choose which side of the unit’ s con- trols will operate. 5-2. Left/Right Select Switch 1 Ref.
OM-230 300 Page 23 5-4. T rigger Hold Switch 1 T rigger Hold Switches T rigger hold allows the operator to weld without holding the gun trigger . • T o use the trigger hold function, place the trigger hold switch in the On position.
OM-230 300 Page 24 SECTION 6 − MAINTENANCE 6-1. Routine Maintenance Y Disconnect power before maintaining. n = Check ~ = Clean l = Replace Reference Every 3 Months Section 4-6, 4-7 l Unreadable Labe.
OM-230 300 Page 25 6-3. Diagnostics 803 063-A 1 LED3 On Right Side Motor Control Board PC1 2 LED3 On Left Side Motor Control Board PC101 3 LED4 On Dual Board PC70 2 1 3 Display On Optional Meter LED3 .
OM-230 300 Page 26 6-4. T roubleshooting Y Disconnect power before troubleshooting T rouble Remedy Wire feeds, shielding gas flows, but electrode wire is not energized. Check cable connections. Check cables for continuity , and repair or replace cables if necessary (see Section 4-6).
OM-230 300 Page 27 Notes.
OM-230 300 Page 28 SECTION 7 − ELECTRICAL DIAGRAM Figure 7-1. Circuit Diagram.
OM-230 300 Page 29 204 716-B.
OM-230 300 Page 30 SECTION 8 − P ARTS LIST 804 785-A 1 2 3 4 5 6 10 12 13 14 16 17 18 19 20 21 26 22 2 Fig 8-4,5 Fig 8-2 Fig 8-3 Fig 8- 6 7 8 9 11 23 24 25 28 Fig 8-4.5 . Hardware is common and not available unless listed. 15 15 14 2 29 29 27 Figure 8-1.
OM-230 300 Page 31 Quantity Description Part No. Dia. Mkgs. Item No. Model 12 16 Figure 8-1. Main Assembly 1 See Note Control Box, (Fig 8-2) 1 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
OM-230 300 Page 32 803 190 . Hardware is common and not available unless listed. 3 4 5 6 5 12 13 15 4 2 14 18 17 16 19 20 21 21 20 22 23 24 1 8 9 10 11 7 Figure 8-2. Control Box Quantity Description Part No. Dia. Mkgs. Item No. Model DS-75S DS-75 D Figure 8-2.
OM-230 300 Page 33 Quantity Description Part No. Dia. Mkgs. Item No. Model D-75S D-75D Figure 8-2. Control Box (Continued) 17 R1,101 073 562 Pot,Cp Std Slot 1t 2. W 10k Linear 2 0 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
OM-230 300 Page 34 804 786-A 1 23 5 6 7 8 9 10 12 13 14 15 16 17 18 20 21 22 23 29 30 15 14 24 25 26 19 27 28 4 . Hardware is common and not available unless listed.
OM-230 300 Page 35 Quantity Description Part No. Item No. Model 12 16 Figure 8-3. Boom Assembly (Fig 8-1 Item 13) 1 010 313 Pin, Cotter Hair .072 X 1.437 4 4 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
OM-230 300 Page 36 See T able 8-1 For Drive Roll & Wire Guide Kits . Hardware is common and not available unless listed. 804 733-A 10 21 2 9 8 7 6 5 4 3 20 2 21 22 15 17 16 18 19 23 1 14 20 13 11 12 24 Figure 8-4. Drive Assembly , Wire Item No. Diagram marking Part No.
OM-230 300 Page 37 . Hardware is common and not available unless listed. 804 734-A 2 3 4 1 5 6 7 Figure 8-5. Drive Assembly With Motor (Left Side Shown) Item No. Diagram marking Part No. Description Quantity Figure 8-5. Drive Assembly With Motor (Figure 8-1 Items 26 and 28) 1 223 252 T achometer , Optical Encoder 1 .
OM-230 300 Page 38 8 7 6 9 1 2 3 4 5 6 7 13 12 11 10 ST-081 760-C . Hardware is common and not available unless listed. Figure 8-6. Support, Hub & Reel Description Part No. Item No. Quantity Figure 8-6. Support, Hub & Reel (Fig 8-1 Item 10) 1 058 427 RING, retaining spool 2 .
OM-230 300 Page 39 Wire Size PD-V for Hard Wire (1 kit or 4 rolls & 1 guide required) PD-U for Aluminum (1 kit or 4 rolls & 1 guide required) Guides for Old Style Drive Rolls (1 each required) Standard Drive Rolls ( 4 required) Fraction Metric PD-V Kit Roll Guide Roll Inlet Intermediate Exit V Groove U Groove VK Groove UC Groove .
Notes.
Notes.
Notes.
Warranty Questions? Call 1-800-4-A-MILLER for your local Miller distributor. miller_warr 2006 − 01 Y our distributor also gives you ... Service Y ou always get the fast, reliable response you need. Most replacement parts can be in your hands in 24 hours.
PRINTED IN USA © 2006 Miller Electric Mfg. Co. 2006 − 01 Miller Elect ric Mfg. Co. An Illinois T ool Wo rks Compa ny 1635 West S pencer S treet Applet on, WI 5 4914 US A International He adquarters.
An important point after buying a device Miller Electric DS-75S16 (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Miller Electric DS-75S16 yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Miller Electric DS-75S16 - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Miller Electric DS-75S16 you will learn all the available features of the product, as well as information on its operation. The information that you get Miller Electric DS-75S16 will certainly help you make a decision on the purchase.
If you already are a holder of Miller Electric DS-75S16, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Miller Electric DS-75S16.
However, one of the most important roles played by the user manual is to help in solving problems with Miller Electric DS-75S16. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Miller Electric DS-75S16 along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center