Instruction/ maintenance manual of the product DAR 1120 Miele
Go to page of 20
Installation Instr uctions DAR 1120, DAR 1130 en - CA DAR 1150, DAR 1220 DAR 1230, DAR 1250 Installation, repair and maintenance work should be performed by a Miele authorized service technician in accordance with national and local safety regulations and the provided installation instructions.
Disposal of packing material The cardboard box and packing materials protect the appliance during shipping. They have been designed to be biodegradable and recyclable. Please recycle. , DANGER Ensure that any plastic wrappings, bags, etc., are disposed of safely and kept out of the reach of babies and young children.
Appliance dimensions 19.
Appliance dimensions 20.
a The hood with exhaust collar is only used in air venting mode with an internal or external blower. b Installation area; Wall/ceiling area respectively for vent hole and outlet installation. For recirculation mode only the outlet installation is required.
a The hood with exhaust collar is only used in air venting mode with an internal or external blower. b Installation area; Wall/ceiling area respectively for vent hole and outlet installation. For recirculation mode only the outlet installation is required.
a Installation area; Wall/ceiling area respectively for vent hole and outlet installation. Appliance dimensions 23.
Distance between cooktop and hood (S) Do not install this exhaust hood over cooktops burning solid fuel. Observe the cooktop manufacturer's instructions when determining the distance between cooktop and lower edge of the hood. Unless the instructions require a greater distance, the adjacent minimum safety distances apply for Miele cooktops.
Distance between cooktop and hood (S) Miele Range Wall / Insert Hood DAR 1120, DAR 1220 (30") DAR 1130, DAR 1230 (36") DAR 1150, DAR 1250 (48") Internal / External blowers DRIB/DREB XL .
The majority of the weight of the installed ventilation system will be supported by the retaining plate. It must be firmly attached to the stud framing behind the drywall. If studs are not available in the required locations, a plywood backing (min. ½" (13 mm) thick) spanning at least two studs must be installed.
Before installation read the information in the "Dimensions" and "Important Safety Instruction" chapters. Under certain conditions, there is a danger of poisonous fumes by when the ventilation system and a furnace drawing interior air run at the same time.
, WARNING Danger of toxic fumes. Gas cooking appliances release carbon monoxide that can be harmful or fatal if inhaled. To reduce the risk of fire and to properly exhaust air, the exhaust gases extracted by the hood should be vented outside of the building only.
– If the exhaust is ducted into an inactive flue, the air must be expelled parallel to the flow direction of the flue. Never connect an exhaust hood to an active chimney, dryer vent, flue, or room venting ductwork. Seek professional advice before connecting an exhaust hood vent to an existing, inactive chimney or vent flue.
, WARNING TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: All electrical work should be performed by a qualified electrician in strict accordance with national regulations (for USA: ANSI-NFPA 70) and local safety regulations.
Total connected load DAR 1120, DAR 1220 with DRIB XL or DREB XL ......6 2 1W DAR 1130, DAR 1230 with DRIB XL or DREB XL ......6 2 4W DAR 1130, DAR 1230 with DRIB XXL or DREB XXL ....8 0 9W DAR 1150, DAR 1250 with DRIB XXL or DREB XXL ....8 1 2W Overhead lights DAR 1120, DAR 1220 .
32.
33.
34.
35.
M.-Nr. 10 219 920 / 01 en - US, CA DAR 1120, 1130, 1150 DAR 1220, 1230, 1250.
An important point after buying a device Miele DAR 1120 (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Miele DAR 1120 yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Miele DAR 1120 - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Miele DAR 1120 you will learn all the available features of the product, as well as information on its operation. The information that you get Miele DAR 1120 will certainly help you make a decision on the purchase.
If you already are a holder of Miele DAR 1120, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Miele DAR 1120.
However, one of the most important roles played by the user manual is to help in solving problems with Miele DAR 1120. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Miele DAR 1120 along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center