Instruction/ maintenance manual of the product GES-801L MGE UPS Systems
Go to page of 22
Always “On” UPS Systems Inc. GES L-Series – Single Phase Input, Single Phase Output Uninterruptible Power Supply USER MANUAL Version 1.4 GES-801L, GES-102L, GES-152L, GES-202L, GES-302L Line Int.
Always “On” UPS Systems Inc..
Always “On” UPS Systems Inc. 3 SAVE THESE INSTRUCTIONS This manual contains important instructions for the GES-801L, GES-102L, GES-152L, GES-202L, GES-302L and should be followed during installation and maintenance of the UPS and batteries. The UPS contains voltages that are potentially h azardous.
Always “On” UPS Systems Inc. 4 TABLE OF CONTENTS INTRODUCTION ................................................................................................................... ..................... 5 SAFETY INSTRU CTIONS ........................
Always “On” UPS Systems Inc. 5 Introduction The L-Series is a Line Interactive UPS sy stem that includes the newest and latest technology enhancements. The Line Inte ractive technology with AVR function (on- line voltage boost-up & buck-down) allows fo r a wide input voltage range of 90 to 150VAC.
Always “On” UPS Systems Inc. 6 Safety Instructions The UPS has its own internal energy source (ba tteries), therefore the output receptacles may have electricity present even though the UPS is disconnected from the utility power.
Always “On” UPS Systems Inc. 7 Presentation Front Panel 1. POWER bar graph (BATTERY CHARGE/LINE VOLTAGE) This displays the present battery charge as a pe rcentage of battery capacity. It also displays the utility line voltage. 2. LOAD bar graph This displays the amount of power required by the load as a percentage.
Always “On” UPS Systems Inc. 8 Rear Panel 11. TELEPHONE/MODEM/ETHERNET SURGE PROTECTION Surge protection for telephone line, modem line, a nd 10BaseT line to m aintain a completely safe connection for INTERNET/INTRANET service. 12. EXTERNAL BATTERY PACK CONNECTOR (optional) Allows for extended runtime.
Always “On” UPS Systems Inc. 9 16. INPUT CIRCUIT BREAKER It trips when the connected loads exceed the pr otected receptacle's capacity. The center plungers of the circuit breakers extend when tripped. 17. SITE WIRING FAULT INDICATORS (RED LED) It illuminates when the UPS is connected to an improperly wired AC power outlet.
Always “On” UPS Systems Inc. 10 Installation Unpacking and Inspection Examine the packaging for damage. Inform the ca rrier imm ediately if and/or when damage is noticed. Retain the packaging for future use. Placement Install the UPS in a protected area with adequate airflow and free of excessive dust.
Always “On” UPS Systems Inc. 11 Connecting the Telephone/Modem/Ethernet Lines Connect a telephone line, modem line, or 10BaseT line into the telephone/modem/Ethernet surge protection sockets on the back of the UPS. Th e RJ-45/RJ-11 modular sockets accept standard single line telephone connections and 10BaseT conn ectors.
Always “On” UPS Systems Inc. 12 Operation Switching “On” the UPS With the UPS plugged in, press and hold the “ON/ TEST” button for at least 1 second to switch the UPS on.
Always “On” UPS Systems Inc. 13 Battery Charge Bar Graph This 5 LED display indicates the present charge of the UPS's batteries as a percentage of the total battery capacity.
Always “On” UPS Systems Inc. 14 Software Options UPSilon 2000 Software The UPSilon 2000 software utilizes standard RS -232 interface to perform monitoring functions, and provides an orderly shutdown of a computer sy stem in the event of power failure.
Always “On” UPS Systems Inc. 15 Computer Interface Port The computer interface port has the following characteristics: The communication port on the back of the UPS m ay be connected to a host com puter. This port allows the computer to monitor the status of th e UPS and control the operation of the UPS.
Always “On” UPS Systems Inc. 16 Battery Replacement Your batteries should run anywhere from 3-5 years before they need to be replaced. Please follow the instructions below for easy, trouble free, battery replacement. 1. Turn the UPS off (follow procedure previously mentioned) 2.
Always “On” UPS Systems Inc. 17 Troubleshooting Please follow the guidelines below for solutions to common problem s: Check UPS input plug and wiring. Check UPS input voltage. Please prepare the information as follows for service personnel: UPS model number and serial num ber Description of problem(s) in detail.
Always “On” UPS Systems Inc. 18 Storage Storage Conditions Store the UPS covered and upright in a cool, dry location, with its battery fully charged.
Always “On” UPS Systems Inc. 19 Battery Bank Installation Install up to 8 battery banks per L Series UPS following the instructions below. Caution: Make sure the UPS is shutdown and unplugged before connecting additional Battery Packs (refer to Switching the UPS “Off” section, page 11) 1.
Always “On” UPS Systems Inc. 20 Specifications Specification Comparison MODEL NO. GES-801L GES-102L GES-152L GES-202L GES-302L MAXIMUM CAPACITY 800VA / 560W 1kVA / 700W 1.
Always “On” UPS Systems Inc. 21 OUTPUT SHORT YES ABNORMAL VOLTAGE YES MODEM OR NETWORK SINGLE LINE (2 wire RJ11) / NETWORK (UTP, RJ45) COMPATIBLE JACKS I/O NOISE PROTECTION COMMON & NORMAL MOD.
Always “On” UPS Systems Inc. 22 CONTACT INFORMATION Additional Purchases or Upgrades Always “On” UPS Systems Inc. Bldg 1 – 150 Campion Road, Kelowna, BC, Canada, V1X 7S8 Phone: (250) 491-9777 Ext 451 Fax: (250) 491-9775 Email: sales@alwaysonups.
An important point after buying a device MGE UPS Systems GES-801L (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought MGE UPS Systems GES-801L yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data MGE UPS Systems GES-801L - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, MGE UPS Systems GES-801L you will learn all the available features of the product, as well as information on its operation. The information that you get MGE UPS Systems GES-801L will certainly help you make a decision on the purchase.
If you already are a holder of MGE UPS Systems GES-801L, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime MGE UPS Systems GES-801L.
However, one of the most important roles played by the user manual is to help in solving problems with MGE UPS Systems GES-801L. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device MGE UPS Systems GES-801L along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center