Instruction/ maintenance manual of the product 3000 RT 3U XL MGE UPS Systems
Go to page of 24
34003641FR/ AA - Page 1 T H E U N I N T E R R U P T I B L E P O W E R P R O V I D E R www.mgeups.com Installation and user manual Pulsar M 2200 RT 2U 2200 RT 3U 3000 RT 2U 3000 RT 3U 3000 RT 3U XL EXB.
34007776EN /AB - Page 2.
34007776E N/AB - Page 3 Introduction Environmental protection MGE UPS SYSTEMS has implemented an environmental-protection policy. Products are developed accordi ng to an eco-design approach. Subst ances This product does not contain CFCs, HCFCs or asbestos.
34007776EN /AB - Page 4 Introduction Pictograms Important instructions that must always be followed. Information, advice, help. Visual indication. Action.
34007776E N/AB - Page 5 Contents 1. Present ation 1.1 St andard positions ..... .............. .............. ................ .............. .............. ............... .............. ............ 6 T ower position ............ .............. ....
34007776EN /AB - Page 6 1. Presentation 1.1 Standard positions Tower position Rack position Dimensions (H x W x D) in mm Pulsar M 2200 RT 2U 440 x 86 x 640 Pulsar M 2200 RT 3U 440 x 131 x 490 Pulsar M.
34007776E N/AB - Page 7 1. Presentation 1.2 Rear panels Pulsar M 2200 / 3000 Pulsar M EXB (optional battery module) 1.3 Control panel (1) USB co mmunicat ion por t (2) RS232 communication port (3) Con.
34007776EN /AB - Page 8 2. Installation 2.1 Unpacking and contents check (30) Pulsar M 2200 or 3000 UPS (31) connection cable to AC-power source (32) 2 connection cables fo r the protected equipment (.
34007776E N/AB - Page 9 2. Installation 2.2 Installation in tower position 2.3 Installation in rack position It is advised to first install the battery module , then the power module above . Follow steps 1 to 4 for module mounting on the rails. The rails and necessary hardware are supplied by MGE UPS SYSTEMS.
34007776EN /AB - Page 10 2. Installation 2.4 Communication ports Connection of RS232 or USB communication port (optional) Installation of the communication cards (optional) The RS232 and USB commun ication ports cannot operate simultan eously.
34007776EN /AB - Page 11 2. Installation 2.5 Connections with a FlexPDU (Power Distribution Unit) module (optional) 2.6 Connections with a HotSwap MBP module (optional) The HotSwap MBP module makes it possible to serv ice or even replace the UPS wit hout affecting the connected loads ( HotSwap function).
34007776EN /AB - Page 12 2. Installation HotSwap MBP-module operation UPS st art-up with th e HotSwap MBP module 1 - Check that the UPS is correctly connected to the Hot Swap MBP module. 2 - Set switch (53) to the Normal po sition. 3 - Start the UPS by pressing the ON/OFF button (27) on the UPS control panel.
34007776EN /AB - Page 13 3. Operation 3.1 Start-up and norm al operation UPS personalisa tion 3.2 Operation on battery power T ransfer to battery power Low-battery warning For the initial start, AC power must be present to detect any wiring e rrors. Subsequently, the UPS can start even if AC power is not present.
34007776EN /AB - Page 14 3. Operation End of battery backup time 3.3 Return of AC power Following an outage, the UPS restarts auto matically when AC power retu rns (unless the restart f unction was disabled via UPS personalisation) and t he load is again supplied.
34007776EN /AB - Page 15 3. Operation Contact open: shut down of UPS Contact closed: start-up of UPS (UPS connected to the network and network energized) Note: local On/Off control via button (27) has priority over the remote control order.
34007776EN /AB - Page 16 4. Access to measurements and personalisation data 4.1 Display menus arrangement 4.2 Access to measurements Press the scroll button (25) to access any status conditions a nd alar ms, then the measurements for voltage, current, frequency, power output and battery backup time.
34007776EN /AB - Page 17 4. Access to measurements and personalisation data Output personalisation (1) These parameters may be modified only when the UPS is OFF. Detailed comments are available in the Persona l Solution-Pac software. ON/OFF personalisati on Battery personal isation 4.
34007776EN /AB - Page 18 5. Maintenance 5.1 Troubleshooting If LED (21) or (22) is ON, a fault or an alarm has occurred. Use the escape button (24) to stop the audio alarm.
34007776EN /AB - Page 19 5. Maintenance Troubleshooting a UPS equipped with the HotSwap MBP module 5.2 Battery-module replacement Safety recommendations The battery can cause electrocutio n and high short-circuit currents.
34007776EN /AB - Page 20 5. Maintenance Mounting the new battery module Carry out the above instruct ions in reverse order. 5.3 Maintenance on a UPS equippe d with the HotSwap MBP module D - Remove the metal protection cover in front of the battery (two screws).
34007776EN /AB - Page 21 5. Maintenance 5.4 Training centre To fully master operation of your MG E UPS SYSTEMS product and carry out level 1 servicing, see our complete range of technical training courses, avai lable in both French and English.
34007776EN /AB - Page 22 6. Appendices 6.1 Technical specifications (1) Depending on the output voltage selected: 200V / 2 08V / 220V / 230V / 240V, the output power is 1980VA / 1980VA / 2200VA / 2200VA / 2200VA.
34007776EN /AB - Page 23 6. Appendices 6.2 Glossary Bypass AC input Bypass line from the AC-power sour ce, controlled b y the UPS, used to directly supply the load if an overload or a malfunction occurs on the UPS. Backup time T ime during which t he load can be supplied by the UPS operating on battery power .
34007776EN /AB MGE UPS SYSTEMS T H E U N I N T E R R U P T I B L E P O W E R P R O V I D E R 140, Avenue Jean Kuntzmann ZIRST - M ontbonno t St Martin 38334 - Saint Ismier Cedex - Fr ance www.
An important point after buying a device MGE UPS Systems 3000 RT 3U XL (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought MGE UPS Systems 3000 RT 3U XL yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data MGE UPS Systems 3000 RT 3U XL - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, MGE UPS Systems 3000 RT 3U XL you will learn all the available features of the product, as well as information on its operation. The information that you get MGE UPS Systems 3000 RT 3U XL will certainly help you make a decision on the purchase.
If you already are a holder of MGE UPS Systems 3000 RT 3U XL, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime MGE UPS Systems 3000 RT 3U XL.
However, one of the most important roles played by the user manual is to help in solving problems with MGE UPS Systems 3000 RT 3U XL. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device MGE UPS Systems 3000 RT 3U XL along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center