METROLOGIC INSTRUMENTS, INC. IS41 10 and IS4125 ScanQuest ® Laser Scan Engine Inst allation and User ’ s Guide.
Copyright © 2006 by Metrologic Instruments, Inc. All rights reserved. No part of this work may be reproduced, transmitted, or stored in any form or b y any means without prior written consent, except by reviewer, who may quote br ief passages in a review, or provided for in the Copyright Act of 1976.
ii T ABLE OF C ONTENTS Introduction Theory of O peration............................................................................... 1 Accessories ........................................................................................... 2 Components of the ScanQues t Engine .
iii T ABLE OF C ONTENTS Canada ................................................................................................ 24 Warnings.............................................................................................. 24 Limited Wa rranty .
1 I NTRODUCTION Metrologic’s ScanQuest ® Engines are mi niature laser bar code scann ers designed to be used in OEM applications a nd decode equipped OEM dev ices. The ScanQuest series provides fast, accurate, reliable sca nning i n a compact, lightweight package.
2 I NTRODUCTION Accessories The following are availab le: IS4125 Decoded Scan Engine Part Numbers Decode Demo Kit 45729 (Includes RS232 adapter cable – MCA951 to 9 PC port) M LPN * D ESCRIPTION M ANUFACTURE /P ART N O .
3 I NTRODUCTION Components of the ScanQuest Scan Engine Figure 1 : IS4110 Figure 2 : IS4125 Sc a n n er wi n d o w: This aperture emits laser lig ht. Infrared Object Sensor: When a specified time has ela psed without any scanning, the unit will enter a “standby” mo de.
4 I NTRODUCTION Label Locations The serial number label is l ocated on the bottom of the unit. On the top of the unit is the “avoid exposure” and mode l number label. The following are examples of these labels: Figure 3 : Labels Maintenance Smudges and dirt can interfere with the pro per scanning of a bar code.
5 IR S ENSOR A CTIVATION An infrared (IR) sensor located behind the scanner window initiates the scanning process. In short range mode the si gnal projects approximat ely 101.61 mm – 177.84 mm (4" – 7") beyond the output window. In long range mode the signal projects approximately 228.
6 D ESIGN S PECIFICATIONS O PERATIONAL Light Source: VLD 650 ± 10 nm CDRH/IEC: Designed to be used in CDRH Class II and IEC Class 2 laser products UL: UL recognized component for Canada and US Depth of Field, UPC 100%: 12.7 mm to 203.2 mm (.5" to 8") for 0.
7 D ESIGN S PECIFICATIONS M ECHANICAL Dimensions: 45.7 mm L x 40.6 mm W x 18.5 mm D ( 1.8" L x 1.6" W x .73" D) Weight: 55 g. (1.94 oz.) IS4125 Termination: Low profile ZIF 12-pi n connector that accepts a 1 mm x 12 position FFC/FPC cable Dimensions: 45.
8 D ESIGN S PECIFICATIONS Specifications for the Supplemental Window The IS4100 ScanQuest series was designed for integration into OEM equipment. The device is designed to function at its maxi mum performance capabilities as shipped.
9 D EFAULT S ETTINGS Many functions of the IS4125 deco de scan engine can be config ured or enabled/disabled. T he decode engine is sh ipped from the factor y configured to a set of default conditions. The default parameter of the decode sca n engine has an asterisk (*) in the charts on the following pages.
10 D EFAULT S ETTINGS Parameter Default RS232 OR RS232 TTL Light Pen Keyboard Wedge USB No Two Second Timeout * Razzberry Tone on Timeout No Tone on Timeout * Three Beeps on Timeout Be.
11 D EFAULT S ETTINGS Parameter Default RS232 OR RS232 TTL Light Pen Keyboard Wedge USB Prefix ID for UPC/EAN Suffix ID for UPC/EAN Bars High * Spaces High Transmit as .
12 D EFAULT S ETTINGS Parameter Default RS232 OR RS232 TTL Light Pen Keyboard Wedge USB Set Minimum Character Length Set Character Lock Length Transmit UPC-A Number Sys.
13 D EFAULT S ETTINGS Parameter Default RS232 OR RS232 TTL Light Pen Keyboard Wedge USB Matrix 2 of 5 Check Digit Hong Kong Matrix 2 of 5 MSI-Plessy Test of Check Digit.
14 D EFAULT S ETTINGS Parameter Default RS232 OR RS232 TTL Light Pen Keyboard Wedge USB Bancomer Mode FedEx parsing Retransmit of Same Code 1st Configurable Prefix ID 2.
15 S CANNER T ERMINATIONS IS4125-17 Connector Pin Assignments Metrologic provides a low profile ZI F 12-pin connector to connect to a 1 mm x 12 position FFC/FPC cable. The pin assignments are as follo ws: Pin Signal Name Function 1 VCC Input. 5VDC (± 0.
16 S CANNER T ERMINATIONS IS4125-38 Connector Pin Assignments Metrologic provides a lo w profile ZIF 12-pin connector to connect to a 1 mm x 12 position FFC/FPC cable. The pin assignments are as follo ws: Pin Signal Name Function 1 VCC Input. 5 VDC (± 0.
17 S CANNER T ERMINATIONS IS4125-41 Connector Pin Assignments Metrologic provides a low profile ZI F 12-pin connector to connect to a 1 mm x 12 position FFC/FPC cable. The pin assignments are as follo ws: Pin Signal Name Function 1 VCC Input. 5 VDC (± 0.
18 S CANNER T ERMINATIONS IS4125-103 Connector Pin Assignments Metrologic provides a low profile ZI F 12-pin connector to connect to a 1 mm x 12 position FFC/FPC cable. The pin assignments are as follo ws: Pin Signal Name Function 1 VCC Input. 5VDC (± 0.
19 S CANNER T ERMINATIONS IS4110 Connector Pin Assignments Metrologic provides a low profile ZI F 10-pin connector that accepts an FPC/FFC cable with a 1.0 mm Pitch and a 0.3 mm end thickness. T his cable is available from Metrologic in various lengths.
20 S CAN S ENSE T IMING IS4110 Timing Diagram The SCAN SENSE pulse occurs once for ea ch flip cycle. A flip cycle represents one scan in each direction (right to left then left to right from the scanner perspective). The HIGH to LOW transit ion of the SCAN SENSE signal initiates the start of the flip cycle.
21 R EGULATORY R EQUIR EMENTS AND W ARNINGS Regulatory Requirements The IS4100 Series ScanQuest Laser Scan engines are designed to meet the requirements of CDRH Class II and IEC Clas s 2 laser products. CDRH Class II/IEC Class 2 are defined as follows: Emission Duration: Greater than 0.
22 R EGULATORY R EQUIR EMENTS AND W ARNINGS Europe The CE Mark is required on products with IS4110 and IS4125 Scan Engin es if the products are to be importe d into European Economc Area (EEA) countries. Use of the CE Mark requires comp liance with Directives and standards dependent upon the type of product.
23 R EGULATORY R EQUIR EMENTS AND W ARNINGS United States Laser Safety To assist with the FDA filing requirements (refer to Regulatory Req uirements on page 21), Metrologic has registered the scan eng ine with the FDA as a component.
24 R EGULATORY R EQUIREMENTS AND W ARNINGS Canada Laser Safety The Radiation Protection Bur eau currently accepts products meeting the FDA standards in Canada.
25 L IMITED W ARRANTY The IS4110 and the IS4125 ScanQues t scanners are manufact ured by Metrologic at its Blackwood, New J ersey, USA facility. The ScanQuest scanners have a tw o (2) year limited warranty from the date of ma nufacture.
26 P ATENTS This Metrologic product may be covered b y, but is not limited to, one or more of the following US Patents: U.S. Patent No.: 5,260,553; 5,340,971; 5,340,973; 5,424,525; 5,468,9 51; 5,484,9.
27 I NDEX A Adapter Ca ble ............................... 2 Applications an d Protoc ols ............ 5 Assignments pin ............................................. 3 B Beam Wi dth ................................... 6 Beeper .......................
28 I NDEX Pin Assignme nts .................... 15–19 Pinout .................................... 15– 19 Protocol s ....................................... 5 R Red LE D ........................................ 2 Regulatory Requirements Canada Laser Safety .
29.
.
.
November 2006 Version 01 Printed in USA 00 - 022 57 C.
An important point after buying a device Metrologic ScanQuest IS4110 (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Metrologic ScanQuest IS4110 yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Metrologic ScanQuest IS4110 - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Metrologic ScanQuest IS4110 you will learn all the available features of the product, as well as information on its operation. The information that you get Metrologic ScanQuest IS4110 will certainly help you make a decision on the purchase.
If you already are a holder of Metrologic ScanQuest IS4110, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Metrologic ScanQuest IS4110.
However, one of the most important roles played by the user manual is to help in solving problems with Metrologic ScanQuest IS4110. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Metrologic ScanQuest IS4110 along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center