Instruction/ maintenance manual of the product IS8000 Metrologic Instruments
Go to page of 40
METROLOGIC INSTRUMENTS, INC. HoloTrak ® IS8000 Series Holographic Scanners Installation and User’s Guide.
Copyright © 2005 by Metrologic Instruments, Inc. A ll rights reserved. No part of this work may be reproduced, transmitted, or stored in an y form or by any means without prior written consent, except by revie wer, who may quote br ief passages in a review, or provided for in the Copyright Act of 1976.
T ABLE OF C ONTENTS Introducti on........................................................................................................... 1 Scanner and A ccessori es ..................................................................................
iii.
1 I NTRODUCTION Metrologic's IS8000 series scanners bring the b enefits of holography to long- range industrial bar code scanni ng. Enclosed in rugged NEMA-12 cas es for industrial environments, the IS8000 series pr ovides omnidirectional scanni ng with optional no code/ wrong code warning.
2 S CANNER AND A CCESSORIES The following is a list of parts included in a stand ard IS8000 kit: ¾ IS8000 Series HoloTrak ® Holographic Scanner ¾ Power Supply ¾ [ MLPN 46-46207-US] 12VDC @ 4.16 Amps, 220VAC or ¾ [ MLPN 46-46207-UK] 12VDC @ 4.16 Amps, 240VAC or ¾ [ MLPN 46-46207-EC] 12VDC @ 4.
3 I NSTALLING THE S CANNER TO THE H OST (S TANDARD F EATURES ) Single HoloTrak ® Installation To avoid potential probl ems, do not power up th e scanner unti l the communication cable is secured to the host. 1. Turn off the host system. 2. Connect the communications cable to the HoloTrak ® and to the host.
4 I NSTALLING THE S CANNER TO THE H OST (S TANDARD F EATURES ) Primary/Secondary setup continued from previous page. All equipment must be connected bef ore powe r-up. After both units complete the power-up diagnostics, the operator will need to program the primary unit with the MetroSet Program provided.
5 I NSTALLING THE S CANNER TO THE H OST (O PTIONAL F EATURES ) Industrial Controller MX001 Interface Option The MX001 Industrial Control Inte rface performs three functi ons. ¾ Through an object sensor input, the scan ner can be alerted to any package present in the scan field.
6 I NSTALLING THE S CANNER TO THE H OST (O PTIONAL F EATURES ) External Speaker Box Option When attached, beeper tones from the scanner are emitted from both the scanner speaker and external speaker to serve as an audible indication of the operation of the scanner.
7 I NSTALLING THE S CANNER TO THE H OST (O PTIONAL F EATURES ) Hand-held Port Option A Non-Decode Hand-Held Scanner can b e connected to an IS8000 series fixed scanner. To avoid potential probl ems, do not power up th e scanner unti l the communication cable is secured to the host.
8 C ONFIGURATION TO THE H OST S YSTEM The scanner is shipped from the factor y c onfigured to a set of default conditions noted in the Default Settings section of this guide. In order for the scanner to communicate with the host system, it will need to be properl y configured.
9 I NSTALLING AND R UN N I N G THE M E T R O S E T ® 2 P ROG R A M How to Start To avoid potential probl ems, do not power up th e scanner unti l the communication cable is secured to the host. 1. Turn off the PC after installing the MetroSet 2 program.
10 P ARTS OF THE S CANNER c Green and Red LEDs The red LED is on when the unit is done p ower up, the VLD is emitting light and the unit is ready to scan.
11 M OUNTING B RACKET I NSTALLATION 1. Locate the mounting bolts on the sides of the scann er. 2. Align the bolts on the scanner with the cha nnels on the mounting bracket. 3. Slide the unit into pl ace until the scanner b olts sit securely in the bottom of the channels.
12 V ISUAL AND A UDIBLE I NDICATORS When the scanner is on, the acti vity of the red and green L EDs indicate the status of the scanner. Flashing Red, No Green During power-up and diagn ostic mode. Steady Red, No Green Unit has completed po wer-up, the VLD is emitting light, and the unit is ready to scan.
13 L ABELS – A C D B.
14 D EPTH OF F IELD AND S CAN P ATTERN C HARACTERISTICS IS8300 Depth of Field and Scan Pattern The depth of field area defined is based conservatively on a 0.
15 D EPTH OF F IELD AND S CAN P ATTERN C HARACTERISTICS IS8400 Depth of Field and Scan Pattern The depth of field area defined is based conservatively on a 0.
16 D EPTH OF F IELD AND S CAN P ATTERN C HARACTERISTICS IS8500 Depth of Field and Scan Pattern The depth of field area defined is based conservatively on a 0.
17 D EPTH OF F IELD AND S CAN P ATTERN C HARACTERISTICS IS8800 Depth of Field and Scan Pattern The depth of field area defined is based conservatively on a 0.
18 M AINTENANCE Smudges and dirt can interfere with the proper scanni ng of a bar code. Therefore, the output window w ill ne ed occasional cleanin g. 1. Spray optical qualit y cleaning fluid ont o l int free, nonabrasive cleanin g cloth. 2. Gently wipe the output window.
19 T ROUBLESHOOTING G UIDE P ROBLEM P OSSIBLE C AUS E ( S ) A CTION N EEDED No LEDs No Power No Scan Pattern No Power Check the power supply and outlet. Alternating Red and Green LEDs flash with a razz tone. Motor Failure Contact a Metrologic service representative.
20 A PPENDIX A Design Specifications IS8800 IS85 00 IS8400 IS8300 Optical Number of VLD 5 5 3 5 Scan pattern Omni Omni Omni Omni Scan l ines pe r sec ond 5,600 5,600 3,360 5,250 Focal planes 4 4 4 5 Scan l ines pe r foca l plane 20 20 12 15 Total scan lines 80 80 48 75 Minimum bar width 0.
21 A PPENDIX A ( CONTINUED ) Design Specifications IS8800 IS85 00 IS8400 IS8300 Electrical Input Voltage 12 VDC 12 VDC 12 VDC 12 VDC Starting Power 69 watts 69 w atts 53 watts 53 watts Operating power.
22 A PPENDIX B Default Settings Many functions of the scanner can be configured, or enab led/disabled. The factory programs the scanner to a set of default parameters. T hese defaults are marked with an asterisk (*) in the default column on the foll owing pages.
23 A PPENDIX B ( CONTINUED ) P ARAM E TE R D EFAULT RS-232 RS-422 L IGHT P EN 200 msec to find Supps 999 Code 128 Coupon Option 999 Code 128 Coupon Conversion 999 378/379 lock on supplement 999 Remote.
24 A PPENDIX B ( CONTINUED ) P ARAM E TE R D EFAULT RS-232 RS-422 L IGHT P EN Fire triac if goo d read/match 999 Fire triac i f bad match 999 Fire triac if no read 999 Triac Duration (sec.
25 A PPENDIX B ( CONTINUED ) P ARAM E TE R D EFAULT RS-232 RS-422 L IGHT P EN Transmit SANYO ID Chr 99 SNI Beetle Mode 9 9 French PC Term not currently supported 99 Xon/Xoff handshaking 9 9 Programmab.
26 A PPENDIX B ( CONTINUED ) P ARAM E TE R D EFAULT RS-232 RS-422 L IGHT P EN Transmit Code 39 Start/Stop Chara cters 99 Transmit ITF Mod 10 check digi t 9 9 Transmit Code 39 Mod 43 check digi t 99 SY.
27 A PPENDIX C IS8000 Series Pinout Connections D ESCRIPTION P IN S IGNAL 1G r o u n d 2 RS-232 Receive Input 3 RS-232 Transmit Output 4 CTS Input 5 RTS Output 6 Reserved 7G r o u n d 8 Reserved 9 RS-.
28 A PPENDIX C IS8000 Series Pinout Connections D ESCRIPTION P IN S IGNAL 1 12VDC Input Power t o Scanner 2 12VDC Input Power t o Scanner 3 Earth Ground 5 Power Ground 4 Power Ground Connector Type on.
A PPENDIX D Limited Warranty The IS8000 series scanners are manufactured by Metrologic at its Blackwood, New Jerse y, U.S.A. facility. The IS8000 series scanners have a two (2) year limited warranty from the date of manufacture.
30 A PPENDIX E Notices This equipment has been tested and found to comply with limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. T hese limits are designed to provide reasona ble protection against harmful interference when the equipment is operate d in a commercial environment.
31 A PPENDIX E ( CONTINUED ) Ach tu ng Die Verwendung anderer als der hier beschrieben en Steuerungen, Einstellungen oder Verfahren kann eine gefährliche Laserstrahlung hervorrufen. Der Kund e sollte unter keinen Umständen versuchen, den Laser-Scanner selbst zu warten.
32 A PPENDIX F Patents "Patent Informa tion This M ETROLOG IC product may be covere d by on e or more of t he follow ing U.S. Patents: U.S. Patent No.
33 I NDEX A ac input/outlet ............. 3-7, 9, 21, 28 accessori es ................................... 2 approvals ......... 4, 13, 20, 21, 30, 31 assignments pin ................................ 10, 27, 28 audible ............................... 6, 10, 12 B bar code .
34 I NDEX specificati ons ......................... 20, 21 system interfaces .......... 1, 8, 20, 22 T tones.............................................. 6 transforme rs .................................. 9 troubleshoot ing ..........................
C ONTACT I NFORMATION AND O FFICE L OCATIONS C ORPORATE H EADQUA RTERS N ORTH A MERICA E UROPEAN , M IDDLE E AST & A FRICA N H EAD QUA RT ERS USA, New Jerse y Germany, Munich Metrologic Instruments, Inc. Metrologic Instruments GmbH Tel: 1-800-ID-METRO Fax : 856-228-6673 Tel: 49-89-89019-0 Fax : 49-89-89019-200 Email: info@metrologic.
March 2005 Printed in the USA 00 - 02377A.
An important point after buying a device Metrologic Instruments IS8000 (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Metrologic Instruments IS8000 yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Metrologic Instruments IS8000 - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Metrologic Instruments IS8000 you will learn all the available features of the product, as well as information on its operation. The information that you get Metrologic Instruments IS8000 will certainly help you make a decision on the purchase.
If you already are a holder of Metrologic Instruments IS8000, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Metrologic Instruments IS8000.
However, one of the most important roles played by the user manual is to help in solving problems with Metrologic Instruments IS8000. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Metrologic Instruments IS8000 along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center