37.4256.018.0 01/2012 Room air conditioner with remote condenser Condizionatore d’ambiente con condensatore remoto Climatiseur avec condenseur a air exterieur • Klimagerät mit außenkondensator A.
This air conditioner is equipped with cooling, drying and fan functions , cooling, drying, heating and fan functions . Details on these functions are provided here following; refer on these descri ptions when using the air conditioner . PRODUCT IDENTIFICA TION .
0 1. Infrared rays remote control unit 0 2. Monitor panel 0 3. Supply air deflector , 4. Return air grille , 5. Outdoor unit 0 6. Flexible tube 0 7. Air filter 0 8. Electric cable with plug 0 9. Service tube for condensate evacuation 10. Outdoor unit basket or support 11 .
SAFETY INSTRUCTIONS ● Read this booklet carefully before using this air conditioner . If you still have any difficulties or problems, consult your dealer for help. ● This air conditioner is designed to give you comfortable room conditions. Use this only for its intended purpose as described in this Instruction Manual.
5 POSITIONING OF OUTDOOR UNIT The outdoor unit must always be kept in vertical position and levelled. Make sure that there are no obstacles around the unit affecting the free circulation of air . A lug at the rear bottom of the unit ensures the minimum distance from the wall (3 cm).
6 OPERA TION WITH THE REMOTE CONTROL UNIT When using the remote control unit, always point the unit transmitter head directly at the air conditioner receiver . TEMPERA TURE SENSOR SELECT OR ● Under normal conditions the room temperature is detected and checked by the temperature sensor placed in the remote controller (I FEEL icon displayed ).
REMOTE CONTROL UNIT EG “NIGHT” BUTTON For details, see "NIGHT MODE". When you press this button in the COOL, HEA T or DRY mode, the mark appears on the display and the microcomputer in the remote control unit will adjust the set temperature to save energy .
8 EG HOW TO SET THE PRESENT TIME COOLING HEA TING 2. Press the SET H button until the present time hour is displayed. Press the SET M button until the present time minutes are displayed. The display will automatically stop flashing. 1. Press the button SEL TYPE three times.
9 EG WHEN DIFFERENCE BETWEEN ROOM TEMPERA TURE AND SET F AN SPEED TEMPERA TURE IS Cooling and 2 °C and over High dehumidifying Between 2 and 1 °C Medium modes: Below 1 °C Low 2 °C and over High Heating mode: Below 2 °C Medium The above mentioned data make reference to the conditioner operating when the sensor on the remote control unit is ON.
10 HORIZONT AL The horizontal air flow can be adjusted by moving the vertical blades to the left or right, as indicated in the following figure. ADJUSTING THE AIR FLOW DIRECTION Set vertical blades to the front position during COOLING/DR Y operation if humidity is high.
● Do not pour water on the unit to clean it. This will damage the internal components and cause an electric shock hazard. ● Never use solvents, or chemical agents when cleaning the indoor unit. Do not wipe the plastic casing using very hot water .
12 EG ACCESSORIES (SUPPLIED ON REQUEST) SUPPLEMENT AR Y BASKET OR SUPPORT GUIDE KIT FOR OUTDOOR UNIT If you want to utilise the air conditioner in several rooms, it is possible to buy varies baskets or support guides for the ins tallation of outdoor unit.
• The use of portable telephones near the air-conditioner may cause disturbance to its normal operation and must be avoided. In case abnormal operation is noticed, (OPERA TION lamp lights but outdoo.
14 Wires color legend Legenda colori fili elettrici Légende des couleurs des fils électriques Beschriftung der Leitungs-Farben Leyenda de los colores de los cable electricos P P i i v v n n a a k k .
Do not vent R410A into atmosphere: R410A is a fluorinated greenhouse gas, covered by Kyoto Protocol, with a Global W arming Potential (GWP) = 1975. Non disperdere R410A nell'atmosfera: R410A è un gas fluorinato a effetto serra, coperto dal protocollo di Kyoto, con potenziale di riscaldamento globale (GWP) = 1975.
S.A.C. - Printed in italy Via V arese, 90 - 21013 Gallarate - V a - Italy T el. +39 0331 755111 - F ax +39 0331 776240 www .argoclima.com.
An important point after buying a device Argoclima TWIN 14A (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Argoclima TWIN 14A yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Argoclima TWIN 14A - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Argoclima TWIN 14A you will learn all the available features of the product, as well as information on its operation. The information that you get Argoclima TWIN 14A will certainly help you make a decision on the purchase.
If you already are a holder of Argoclima TWIN 14A, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Argoclima TWIN 14A.
However, one of the most important roles played by the user manual is to help in solving problems with Argoclima TWIN 14A. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Argoclima TWIN 14A along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center