ELECTRIC DRYER INSTALLATION INSTRUCTIONS U.S.A. ONLY Para una version de esta s instruccione s en españo l, visite www .Whirlpool.com T ABLE OF CONTENTS TABLE OF CONTENTS .................................. ................................ 1 DRYER SAFETY.
2 INST ALLA TION REQUIREMENTS T ools and Parts G ather the r equired tools and parts be fore starting installation. Read and follow the instructions provid ed with any tools listed here.
3 Location Requirements Y ou will need ■ A location that allows proper exhaust installation. See “V enting Requirements.” ■ A separate 30-amp circuit. ■ If using a power supply cord, a grounded electrical outlet within 2 ft (6 10 mm) of either side of dryer .
4 ELECTRIC DR YER POWER HOOKUP Electrical Requirements It is your r esponsi b ility ■ T o contact a qualified electrical installer . ■ T o be sure that the electrical connection is adequate and in conformance with the National E lectrical Code, ANSI/NFP A 70- latest edition and all loca l codes and ordinances.
5 Electrical Connection W ARNIN G Fire Hazar d Use a new UL listed 30 amp power supply cord. Use a UL listed strain relief. Disconnect power b efore making electrical connections. Connect neutral wire (white or center wir e) to center terminal (silver).
6 block opening, screw r emova ble conduit connec tor onto strain relief threads. B C A A. Removable conduit connector B. Hole below terminal block opening C. Strain relief threads ■ Put direct wire cable thr ough strain relief. Strain r elief should have a tight fit with drye r cabinet and be in a horizontal position.
7 3. Connect ground wir e (green or bar e) of power supp ly cord to external ground conductor scr ew . Tighten screw . A. External ground conductor screw B. Neutral ground wire C. Ground wire (green or bare) of power supply cord D. 3/4" (19 mm) UL listed str ain relief E.
8 4. Place the hooked ends of the othe r direct wire cable wir es under the outer termin al block screws (hooks facing right). Squeeze hooked ends together . Tighten screws. 5. Tighten strain relief scr ew . 6. Insert tab of terminal block cover into slot of dryer rear panel.
9 2. Place the hooked end of the neutral wire (white or center wir e) of direct wir e cable under the cente r screw of terminal block (hook facing right). Squeeze hooked end together . Tighten screw . A C D E B D. Neutral wire (white or center wire) E.
10 VE N T I N G V enting Requirements W ARNIN G Fire Hazar d Use a heavy metal vent. Do not use a plastic vent. Do not use a metal foil vent. Failure to follow these instructions can result in death or re. WARNING: T o reduce the risk of fire, this dryer MUST BE EXHAUSTED OUTDOORS.
Improper ventin g can cause moistur e an d lint to collect in d oors, which may result in: Moi s ture damage to woodwork, furniture, paint, wallpaper, carpet s , etc.
12 Determine vent path ■ Select the route that will provide the straightest a nd most direct path outdoors. ■ Plan the in stallation t o use th e fewest number of elbows and turns. ■ When using elbows or m aking tur ns, allow as much r oom as possible.
13 4. Using pliers, tighten the coupling s with an additional two-thirds turn . NOTE: Do not overtighten. Damage to the coupling can result. 5. Attach “Y” connector to brass male end of small hose. Screw on coupling by hand until it is seated on connector .
14 All Models: 13. Select a Timed Dry heated cycle, an d start the dryer . Do not select the Air Only T emperatur e setting. If the dryer will not start, check the following: ■ Controls are set in a running or “On” position. ■ Start butt on has be en pushed firmly .
15 3. Remove the 4 screws from the opposite side of the door . 4. Install the 2 hinges to the front panel of the dryer using 4 screws. Use the non-slotted side to attach the hinge to the fr ont panel. 5. Instal l screws in top hinge holes in the door .
Press any key to clear the code from the display and return to the estimated ti me r emaining. T ry th e following: Check to see if a household fuse has blown or circuit breaker has tripped. Electric dryers use two household fuses or breakers. Replace the fuse or reset the circuit br eaker .
An important point after buying a device Maytag W10267633A (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Maytag W10267633A yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Maytag W10267633A - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Maytag W10267633A you will learn all the available features of the product, as well as information on its operation. The information that you get Maytag W10267633A will certainly help you make a decision on the purchase.
If you already are a holder of Maytag W10267633A, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Maytag W10267633A.
However, one of the most important roles played by the user manual is to help in solving problems with Maytag W10267633A. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Maytag W10267633A along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center