Instruction/ maintenance manual of the product MDG30PCC Maytag
Go to page of 36
Part No. 1 13201-7 MDG30PCC Inst allation Manual (30 lb Single Pocket, Phase 7 Coin) RET AIN THESE INSTRUCTIONS IN A SAFE PLACE FOR FUTURE REFERENCE A VER TISSEMENT : Assurez-vous de bien suivre les i.
FOR YOUR SAFETY Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. POUR VOTRE SÉCURITÉ Ne pas entreposer ni utiliser d’essence ni d’autres vapeurs ou liquides inflammables à proximité de cet appareil ou de tout autre appareil.
IMPOR T ANT YOU MUST DISCONNECT AND LOCK OUT THE ELECTRIC SUPPL Y AND THE GAS SUPPL Y OR THE STEAM SUPPL Y BEFORE ANY COVERS OR GUARDS ARE REMOVED FROM THE MACHINE TO ALLOW ACCESS FOR CLEANING , ADJUSTING , INST ALLA TION, OR TESTING OF ANY EQUIPMENT PER OSHA (Occupational Safety and Health Administration) ST ANDARDS.
W ARNING The dryer must never be operated with any of the back guards, outer tops, or service panels removed. PERSONAL INJUR Y OR FIRE COULD RESUL T . IMPOR T ANT PLEASE OBSER VE ALL SAFETY PRECAUTIONS displayed on the equipment and/or specified in the installation manual included with the dryer .
SECTION I SAFETY PRECAUTIONS ................................................................................................ 2 SECTION II SPECIFICA TIONS ................................................................................................
2 Maytag Co. 1 1320 1 - 7 SECTION I SAFETY PRECAUTIONS W ARNING: For your safety , the information in this manual must be followed to minimize the risk of fire or explosion or to prevent property damage, personal injury , or loss of life. W ARNING: The dryer must never be operated with any of the back guards, outer tops, or service panels removed .
1 13201 - 7 Maytag Co. 3 W ARNING: DO NOT use heat for drying articles that contain plastic, foam, sponge rubber , or similarly textured rubber materials.
4 Maytag Co. 1 1320 1 - 7 SECTION II SPECIFICA TIONS Shaded areas are stated in metric equivalents 3/10/04 NOTE: The manufacturer reserves the right to make changes in specifications at any time without notice or obligation. MA X I MUM C A P A C I T Y (D RY W E I GHT ) 3 0 l b s 13.
1 13201 - 7 Maytag Co. 5 S pecifications NOTE: The manufacturer reserves the right to make changes in specifications at any time without notice or obligation.
6 Maytag Co. 1 1320 1 - 7 SECTION III INST ALLA TION PROCEDURES Installation should be performed by competent technicians in accordance with local and state codes. In the absence of these codes, the installation must conform to applicable American National Standards: ANSI Z223.
1 13201 - 7 Maytag Co. 7 B. LOCA TION REQUIREMENTS Before installing the dryer , be sure the location conforms to local codes and ordinances. In the absence of such codes or ordinances the location must conform with the National Fuel Gas Code ANSI.Z223.
8 Maytag Co. 1 1320 1 - 7 C. DR YER ENCLOSURE REQUIREMENTS Bulkheads and partitions should be made of noncombustible material. NOTE: Allowances must be made for opening the control door . A 30-inches (76.2 cm) for optimum opening of load door . B The maximum thickness of the bulkhead is 4-inches (10.
1 13201 - 7 Maytag Co. 9 D. FRESH AIR SUPPL Y REQUIREMENTS The air supply (make-up air) must be given careful consideration to ensure proper performance of each dryer . An unrestricted source of air is necessary for each dryer . As a general rule, an unrestricted air entrance from the outdoors (atmosphere) of a minimum of 1 square foot (0.
10 Maytag Co. 1 1320 1 - 7 E. EXHAUST REQUIREMENTS Exhaust ductwork should be designed and installed by a qualified professional. Improperly sized ductwork will create excessive back pressure which re.
1 13201 - 7 Maytag Co. 11 SINGLE DR YER VENTING HORIZONT AL VENTING When horizontal single 8-inch (20.32 cm) venting is used, the ductwork to the outlet cannot exceed 30 feet (9.14 meters) refer to Illus. A below . This calculation of 30 feet (9.14 meters) compensates or allows for the use of a maximum of only one (1) elbow .
12 Maytag Co. 1 1320 1 - 7 MUL TIPLE DR YER (COMMON) VENTING HORIZONT AL VENTING If it is not feasible to provide separate exhaust ducts for each dryer , ducts for individual dryers may be channeled into a common main duct. Each dryer is provided with a back draft damper .
1 13201 - 7 Maytag Co. 13 VER TICAL VENTING Illus. D MUL TIPLE DR YER VENTING (VERTICAL) The maximum length of venting from the last dryer to where it exhausts: V ertical venting must not exceed 25 feet (7.
14 Maytag Co. 1 1320 1 - 7 GAS ELECT R I C A L SER VI CE S PECI FI CAT I O N S ( PER DR Y ER ) N OT ES: A. B. Wh en f u ses are u sed t h ey mu st be du al el emen t, t ime delay , cu rren t limitin g, class R K 1 or R K 5 O N L Y .
1 13201 - 7 Maytag Co. 15 For 1 10V Applications Sin gl e- P h ase ( 1ø ) El ect rica l C o n n ection s Lea ds Bl ack + Posit i v e Wh i te - Neutral G reen G ro und or L2 3. Grounding A ground (earth) connection must be provided and installed in accordance with state and local codes.
16 Maytag Co. 1 1320 1 - 7 G . GAS INFORMA TION It is your responsibility to have ALL plumbing connections made by a qualified professional to ensure that the gas plumbing installation is adequate and conforms to local and state regulations or codes.
1 13201 - 7 Maytag Co. 17 T Y P E OF GAS NA TURA L L I QUI D P RO P A NE Man i f ol d P r essu re* 3.5 in ch es W .C. 8. 7 m b 10. 5 i n ch es W . C . 26. 1 m b I n -Lin e P r essu r e 6. 0 - 12. 0 i n ch es W .C. 14. 92 - 29. 9 mb 11 . 0 i nc he s W.
18 Maytag Co. 1 1320 1 - 7 3. Piping Connections ALL components/materials must conform to National Fuel Gas Code Specifications ANSI Z223.1-LA TEST EDITION, or in Canada, CAN/CGA-B149.
1 13201 - 7 Maytag Co. 19 Consistent gas pressure is essential at ALL gas connections. It is recommended that a 3/4-inch (19.05 mm) pipe gas loop be installed in the supply line servicing a bank of dryers. An in-line pressure regulator must be installed in the gas supply line (header) if the (natural) gas pressure exceeds 12.
20 Maytag Co. 1 1320 1 - 7 IMPOR T ANT : If during installation the lint door safety chain was disconnected, it must be reconnected or personal injury may result. 10 . Rotate the basket (tumbler) and drum by hand to be sure it moves freely . 1 1. Check bolts, nuts, screws, terminals, and fittings for security .
1 13201 - 7 Maytag Co. 21 NOTE: The sail switch can be checked for proper operation by opening the lint door while heating circuit (gas burner or electric oven) is active (on). The heating unit should shut off within a few seconds. If not, make necessary adjustments to the sail switch.
22 Maytag Co. 1 1320 1 - 7 2. Mechanical Drop/Rotary Coin Meter or Slide Coin Meter a . Insert coin and turn knob (rotary type meter), or for slide meter unit, push in coin chute. b. Select temperature. c . Push the “Start” button. d. T o stop dryer , open the main door .
1 13201 - 7 Maytag Co. 23 SECTION IV SER VICE/P AR TS INFORMA TION A. SER VICE Service must be performed by a qualified trained technician, service agency , or gas supplier . If service is required, contact the dealer from whom the Maytag equipment was purchased.
24 Maytag Co. 1 1320 1 - 7 SECTION V W ARRANTY INFORMA TION A. RETURNING W ARRANTY CARDS Before any dryer leaves the manufacturer ’ s test area, a warranty card is placed on the back side of the main door glass.
1 13201 - 7 Maytag Co. 25 SECTION VI ROUTINE MAINTENANCE A. CLEANING A program and/or schedule should be established for periodic inspection, cleaning, and removal of lint from various areas of the dryer , as well as throughout the ductwork system. The frequency of cleaning can best be determined from experience at each location.
26 Maytag Co. 1 1320 1 - 7 W ARNING: THE ACCUMULA TION OF LINT IN THE EXHAUST DUCTWORK CAN CREA TE A POTENTIAL FIRE HAZARD . W ARNING: DO NOT OBSTRUCT THE FLOW OF COMBUSTION AND VENTILA TION AIR. W ARNING: INSPECT AND REMOVE ANY LINT ACCUMULA TION, WHICH CAN CAUSE THE BACK DRAFT DAMPER TO BIND OR STICK.
1 13201 - 7 Maytag Co. 27 SECTION VII DA T A LABEL INFORMA TION When contacting the Maytag dealer , certain information is required to ensure proper service/parts information. This information is on the data label, which is located on the upper left side panel area behind the top control (access) door .
28 Maytag Co. 1 1320 1 - 7 SECTION VIII PROCEDURE FOR FUNCTIONAL CHECK OF REPLACEMENT COMPONENTS 1. Microprocessor Controller (Computer) Board a . Upon completing installation of the replacement microprocessor controller (computer) board, reestablish power to the dryer .
1 13201 - 7 Maytag Co. 29 2. For Models with Direct Spark Ignition (DSI) Module (T ype I) Theory of Operation: Start the drying cycle. When the gas burner ignites within the chosen trial for ignition time (6-seconds), the flame sensor detects gas burner flame and signals the DSI module to keep the gas valve open as long as there is a call for heat.
30 Maytag Co. 1 1320 1 - 7 SECTION IX MANUAL RESET BURNER HI-LIMIT INSTRUCTIONS A. PHASE 7 This dryer was manufactured with a manual reset burner hi-limit thermostat, which is monitored by the Phase 7 computer .
1 13201 - 7 Maytag Co. 31 Notes _____________________________________________________________________________________________________________________ __________________________________________________.
Part No. 1 13201 7 - 09/16/08 - 10.
An important point after buying a device Maytag MDG30PCC (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Maytag MDG30PCC yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Maytag MDG30PCC - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Maytag MDG30PCC you will learn all the available features of the product, as well as information on its operation. The information that you get Maytag MDG30PCC will certainly help you make a decision on the purchase.
If you already are a holder of Maytag MDG30PCC, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Maytag MDG30PCC.
However, one of the most important roles played by the user manual is to help in solving problems with Maytag MDG30PCC. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Maytag MDG30PCC along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center