Instruction/ maintenance manual of the product DVR-38 Marquis
Go to page of 31
MARQUIS 38 DVT-38 & DVR-38 Direct Vent Gas F ireplace 7116 Beat ty D r Missio n, BC V 2V 6B4 Canada For use with Natural Gas or Propane* Installer: Please leave this manual w ith the appliance own.
.
Mar quis 38 3 CONTENTS Introduction 4 General Information 5 Appliance Description and Dimensions 6 Framing Dimensions 7 Clearance to Combustibles 8 Possible Fireplace Locations 9 Venting Instructions .
Mar quis 38 4 INTRODUCTION Thank you for purchasing the Marquis DV-38 Direct Vent Built- in Gas Fireplace. The Marquis DV-38 is one of the most advanced gas fireplaces on the market. It is designed using the latest technology and manufactured to the highest quality.
Mar quis 38 5 GENERAL INFORMA TION This ap pliance is liste d by Warnock Her sey for use in both th e Unite d State s and Ca nada. I t is tested a nd certified to the following US and Canadian g as appliance stan dards. - ANSI Z21.50- 1996 / CGA 2.22-M 96, V ented G as Fire place a nd Heat ers - CAN/CGA-2.
Mar quis 38 6 APPLIANCE DESCRIPTION & DIMENSIONS GAS VALVE CONVECTION FAN SPEED CONTROL (Optional) TOP LOUVERS GLASS DOOR APPLIANC E DI MENSIONS FRONT VI EW 38” 23-1/2” 39-3/4” TOP VIEW SIDE.
Mar quis 38 7 FRAMING DIMENSIONS FRAMING DIMENSIONS 38” 16- ¼ ” 38- ½ ” 26- ¼ ” 38” 54” TER MIN AT IO N FRAMING 11” 10” 38” *32- ¼ ” 16- ¼ ” 37” 12 ¾ ” 1 2 3 4 2” WHEN INSTALLING A SHELF OVER THE TOP OF REAR / TOP VENT MODEL DV38, THE F OLLOWING APPLIES: 1.
Mar quis 38 8 CLEARANCE T O COMBUSTIBLES CLEARANCES TO COMBUSTIBLES BACK 0” to sta nd-of f s SID ES 0” to stand- off s TOP 0” to stand- off s BOTTO M 0” ADJACENT S IDE WALL 1” to si de of f acepla te MANTLE see d iag ram VENT 1” to outside side and bottom surface, 2” to outs ide top sur f ace.
Mar quis 38 9 B C F D E A A Cross Corner B Flush w ith Wa ll C Flat on W all Co rner D Flat on Wa ll E Is l a n d F Room Divi der 15 ft Max . 15 ft Max . POSSIBLE FIREPLACE LOCA TIONS LOCATING GAS FIREPLACE This app liance m ust be i nsta lled in any location that i s free of plumbing , electr ical wiri ng and h eating or air cond itioni ng duct s.
Mar quis 38 10 VENTING INSTRUCTIONS VENTING The appliance will not function without being con nected to a proper venting s ystem. This appliance may use 4” and 7” gas flex vents with DV-38 listed vent componen ts, or Simpson Duravent 4 x 6-5/8 direct vent systems with Simpson Dura-ve n t Adaptor (SDA-3) .
Mar quis 38 11 VENTING INSTRUCTIONS Cont... • Chart is f or one 90° bend, with 1/4” vertical raise mi nimum per foot of horizontal length. • For each additional 90° or two 45° , add 1f t of vertical height. • Maximum two 90º bends, or equivalent.
Mar quis 38 12 VENTING INSTRUCTIONS Cont... RESTRICTOR PLACEMENT “FOR ABOVE 7 FOOT VE RTICAL RISE VENTED APPLICATIONS ONLY” Vertical Venting Between Seven Feet (7’) an d Ten Feet (10’) must use Restrictor # 1. V ertical Venting Between Ten Feet (10’) and Twenty-four Feet (24’ ) for Rooftop Terminations m ust use Restrictor #2 .
Mar quis 38 13 VENTING INSTRUCTIONS Cont... 24 Canadian Installations (1) US Installations (2) Canadian Installati ons (1) US Installations (2) A= Cl ear an ce a b ov e gr ad e, v era nd a , porch, de.
Mar quis 38 14 GAS CONNECTIONS Before co nnecting th e appliance to the gas su ppl y line, double check that the app liance y ou hav e purcha sed i s desi gned for t he gas type y ou are us i ng. The ga s type markings are locate d on the cer t ifica tion la bel a nd also on t he appl i ance ’s gas valve.
Mar quis 38 15 GLASS DOOR INSTRUCTIONS GLASS DOOR WARNING: Do not attempt to remove the glass door when the appliance is hot. Removing the Glass Door Remove the top and bottom louvers. There are two latches under the firebox. Undo the latches, swing the bottom of the door awa y from the appliance and then lift the door off the top retaining tabs.
Mar quis 38 16 LOG PLACEMENT INSTRUCTIONS PLACEMENT OF LOGSET, FIBER COALS & EMBER WOOL • Place the back log at the back of the burner tray as shown, behind the two tabs on the burner tray. • Place the front log on top of the burner as shown. The metal tabs protruding from the bottom of the log straddle the side of the burner top.
Mar quis 38 17 F AN & V AL VE WIRING DIAGRAM/INSTRUCTIONS ELEC TRICA L CONNEC TION S (for op tion al con vect ion fan kit FK 36 /38 on ly) • Install the fan first. Remove the lower louvers a nd gently place the bottom front lip of the blower mounting bracket into the opening.
Mar quis 38 18 INITIAL ST AR T UP INSTRUCTIONS FOR YOUR SAFETY, REA D BEFORE LIGH TING WARNING : If you do not follow these instructions exactly, a fire or explosion may result, causing property damage, personal injury or loss of life.
Mar quis 38 19 Set the thermostat, if present, to the lowest level. Press slightly and turn the control knob clockwise 3 to the OFF position and wait 5 minutes; thus allowing any gases to escape which may have accumulated in the combustion chamber. Note: LP gases do not vent upward.
Mar quis 38 20 MAINTENANCE CAUTION : Only conduct m aintenance on a cold appliance. The exterior painted surfaces, glass and gold tr ims m a y be cleaned with a soft, non-abrasive cloth and water or a suitable, mild, non-abrasive cleaner.
Mar quis 38 21 TROUBLESHOOTING SYMPTOM ACTION Pilot w ill not light after press ing the sparker man y times. 1. When lighting the appliance for the f irst time after installation or after servicing, there is air in the gas line. It takes a while for all the air to purg e out of the pi lot before gas can reach the pilot and ignite.
Mar quis 38 22 TROUBLE SHOOTING Cont... SYMPTOM ACTION The main burn er does not turn on with the pilo t li t. Cont... 3. Check to make sure the th ermostat is set high enough to turn on the appliance. 4. Check that the remote switch or the thermostat is turned on.
Mar quis 38 23 SER VICING Before servicing, read the terms and conditions of the Archgard warranty at the back of the manual. Contact the Archgard authorized dealer where you purchased the appliance and provide them with details of the problem and the installa tion information which the installer filled out at the back of the manual.
Mar quis 38 24 • Remove the bottom grill. • The pressure test taps are located on front of the valve. • The supply pressure is marked ‘ IN ’ and the manifold pressure is marked ‘ OUT ’. There is also an arrow marking the direction of gas flow.
Mar quis 38 25 SER VICING Cont... IF YOUR GLASS BREAKS CONVERTIBLE PILOT O RIFICE In the event your glass cracks or breaks, it must be replaced by the exact same size and material. It is made from high temperature cer amic material. See replacem ent parts list and contact your nearest Archgard dealer.
Mar quis 38 26 • Disconnect power to the gas fireplace. • Remove the fan speed mounting bracket. • The convection blower is located at the bottom of the appliance at the back. Remove the three screws holding the blower. • Rotate the blower to the left and carefull y take the blower out with its back end out first.
Mar quis 38 27 Parts can be ordered through your local dealer or distributor by giving IT EM # and DESCRIPTION. Item # Item Description Qty Unit 200-0044 OW NER’ S MANUAL, MARQU IS DV-38D & DVT3.
This Li mited Warrant y is made b y ARCHGARD INDUST RIES LTD., he re inafter referred to as “Archgard”. Archgard warrants to the ori ginal purchase r of an Arc hgard ga s b urning f i r eplace( s) that t he produc t will be fr ee from defe c ts in mater ia ls and w orkmans hi p under normal use an d service, for a “lifetime”.
.
Postage WARRANTY REGISTRATION ARCHGARD INDUSTRIES LTD. 7116 BEATTY DRIVE MISSION, B.C. CANADA V2V 6 B4 FOLD DO W N AT LI NE FOLD DOWN AT LINE & TAPE CLOSED CUT ALONG LI NE CUT ALON G LINE CUT ALON.
Archgard Industries Ltd. 7116 Beatty Drive Mission, British Columbia, Canada V2V 6B4 Telephone: 604-820-8262 Telephone Toll Free: 877-820-9800 Fax: 604-820-8881 Fax Toll Free: 866-820-2802 Website: www.
An important point after buying a device Marquis DVR-38 (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Marquis DVR-38 yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Marquis DVR-38 - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Marquis DVR-38 you will learn all the available features of the product, as well as information on its operation. The information that you get Marquis DVR-38 will certainly help you make a decision on the purchase.
If you already are a holder of Marquis DVR-38, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Marquis DVR-38.
However, one of the most important roles played by the user manual is to help in solving problems with Marquis DVR-38. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Marquis DVR-38 along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center