Instruction/ maintenance manual of the product 3638R Marley Engineered Products
Go to page of 16
READ & SA VE THESE INSTRUCTIONS MODELS 2438, 3038R & 3638R WHOLE HOUSE VENTILA T ORS CEILING INST ALLA TION ONL Y NOTE: MODELS 3038R AND 3638R ARE A V AILABLE FOR CEILING AND W ALL INST ALLA TION. W ARNING: TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT USE THIS F AN WITH ANY SOLID-ST A TE SPEED CONTROL DEVICE.
IMPORT ANT SAFETY INSTRUCTIONS W ARNING: TO REDUCE THE RISK OF FIRE, ELECTRICAL SHOCK OR INJURY TO PERSONS, OBSER VE THE FOLLOWING: 1. Do not use this fan with any Solid-State Speed Control Device. 2. Use this unit only in the manner intended by the manufacturer .
(1/2 A X B = AREA Sq. Ft.) GABLE EXHAUST (A X B = AREA Sq. Ft.) EA VE EXHAUST (A X B = AREA Sq. Ft.) GABLE EXHAUST A TTIC AIR INT AKE AND DISCHARGE Y our Whole House V entilator will be discharging a large volume of air into the attic every minute. Provisions must be made to allow this air to escape to the outside.
3 CEILING INST ALLA TION — MODEL 3038 USED WITH AN A3024 SHUTTER ONL Y NO FRAMING OR CUTTING OF JOISTS REQUIRED FOR 16” O.C. JOISTS. F AN LOCA TION AND MOUNTING STEP 1 - Fan should be located in center of house, preferably in hallway or corridor .
4 FOR CEILINGS WITH JOISTS ON 16 ” CENTERS MODEL A3024 SHUTTER FOR CEILINGS WITH JOISTS ON 24 ” CENTERS MODEL A3024 SHUTTER FIG. 4 FIG. 5 FIG. 6 FIG.
In attic reassemble channels and housing with the original bolts and lockwashers. T ighten these bolts securely . STEP 5B - With fan in attic remove adhesive backing from 1/2 ” x 1/2 ” gasket material and attach to the two bottom flanges of fan which will rest on the joists.
SHUTTER INST ALLA TION STEP 7 - Unpack Model A3024 shutter and read instructions included. Note that the first part of the shutter instructions refer to cutting the shutter hole, which you have already done, and so they may be disregard- ed. Follow the remaining instructions to adjust springs so that shutters open and close freely .
7 CEILING INST ALLA TION — ALL OTHER MODELS F AN LOCA TION & MOUNTING STEP 1 - Fan should be located in center of house, preferably in hallway or corridor . This will allow air to be drawn from all parts of living space. (See Fig. 1.) STEP 2 - Lightly mark a square opening on ceiling (with pencil) where shutter is to be located.
8 FOR CEILINGS WITH 2 X 4 JOISTS ON 16 ” CENTERS Determine which ceiling joists are to be cut per STEPS 2 & 3. Locate your fan size below and follow specific instructions.
9 FOR CEILINGS WITH 2 X 4 JOISTS ON 24 ” CENTERS Determine which ceiling joists are to be cut per STEPS 2 & 3. Locate your fan size below and follow specific instructions. FOR CEILINGS WITH 2 X 6 JOISTS ON 24 ” CENTERS Determine which ceiling joists are to be cut per STEPS 2 & 3.
10 BROWN WHITE BLACK WHITE (COM) RED (LOW) RED (LOW) BLUE (MED) BLACK (HI) BLUE (MED) BLACK (HI) SHUTTER INST ALLA TION STEP 6 - Unpack shutter and read instructions included. Carefully follow these instructions to adjust the spring tension on your shutter .
11 120V , 60 HZ FIG. 15 F AN MOTOR OUTLET BOX CONTROL OUTLET BOX GND. SCREW BLACK (HI) BLUE (MED) MOTOR RED (LOW) BLACK (HI) BLUE (MED) RED (LOW) WHITE (COM) CONTROL BLACK BROWN 120V SUPPL Y A V AILABLE A T CONTROL WHITE STEP 4 - After determining which diagram applies, pull wires to fan.
12 STEP 5 — Position fan on frame and secure with (4) wood or lag screws (number 12 x 1 1/2 ” preferred) through holes drilled in STEP 4. FIG. 4 FIG. 5 SEE CHART DOUBLE 2 X 6 HEADER 2 X 4 FRAMING SECURE UNIT IN PLACE WITH 2 ” X 2 ” FURRING STRIPS INSIDE.
13 ACCESSOR Y CONTROL MODEL 1012A Timer Switch may be used to control the fan, if it is desirable to run the fan after retiring at night. T ime switch can be set manually to run up to 12 hours, turning fan off automatically at the pre-set time. OPERA TING HINTS AND SUGGESTIONS 1.
14 REF . DESCRIPTION QTY . MODEL NO. USED ON 13 3 ” V -Belt, FHP 4L330 1 2438 33 ” V -Belt FHP 4L370 1 3038, 3038R 44 ” V -Belt FHP 4L440 1 3638, 3638R 2 Sheave, 4 ” OD Motor 1 2438 Sheave, 3.
LIMITED W ARRANTY Dear Customer , Thank you for your interest in Marley Engineered Products products. We ’ re sure you will enjoy its benefits for many years to come. Please take a minute to fill out the following information and keep it in your permanent records.
An important point after buying a device Marley Engineered Products 3638R (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Marley Engineered Products 3638R yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Marley Engineered Products 3638R - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Marley Engineered Products 3638R you will learn all the available features of the product, as well as information on its operation. The information that you get Marley Engineered Products 3638R will certainly help you make a decision on the purchase.
If you already are a holder of Marley Engineered Products 3638R, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Marley Engineered Products 3638R.
However, one of the most important roles played by the user manual is to help in solving problems with Marley Engineered Products 3638R. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Marley Engineered Products 3638R along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center