Important Safety Information Warning: • Always turn off power at the main power source by unscrewing fuse or switching circuit breaker to the off position before installing, removing, cleaning, or servicing thermostat. • Read all of the information in this manual before installing or programming this thermostat.
Features • Four pre-programmed setpoints for each day of the week. • Fast and easy programming for setting all days of the week simultaneously . • Energy efficient recovery . • Residual cooling for added air -conditioning efficiency . • T wo “AA” ENERGIZER brand batteries retain program memory, even during power outages.
FIGURE 1 Installing the Model 8355 Thermostat NOTE: For new installations, mount thermostat on inside wall, 4-5 feet above the floor . Do not install behind a door , in a corner , near air vents, in direct sunlight, or near any heat or steam generating fixtures.
FIGURE 3 7. Drill the marked holes using a 3/16" drill bit. NOTE: Enclosed plastic anchors do not require a drilled hole for drywall. 8. T ap plastic anchors into the holes. 9. Align base with plastic anchors and feed wires through opening. See Fig 4.
Programming Guide Set T ime of Day , Day of Week, T emperature Differential, Residual Cooling 1. Press SET & PROG/MAN. Release simultaneously . Press or to change T ime of Day . 2. Press 3. Press T o Change Day of Week 4. Press 5. Press T o change 1st Stage T emperature Differential NOTE: The T emperature Differential is Factory preset at 1°.
Changing Fahrenheit (F) to Celsius (C) Press and Hold SET Press Release both simultaneously . Energy Efficient Recovery The energy efficient recovery feature looks ahead up to 2 hours prior to the end of the setback (or set-up) period to begin monitoring pe rf or mance and calculating when to turn on your system.
Setting Daily Programming 1. Place COOL-OFF-HEA T -EM in COOL position. 2. Press SET button. The display will show a number from 1 to 7. This number represents the day of the week to be programmed. If programming individual days, press either or button to adjust the day of the week to program (1=Mon.
3. Press PROG/MAN button until indicator is in PROG position. T emporary Program Override T o temporarily increase or decrease temperature Press or The thermostat will automatically return to the program at the next scheduled setting change or after four hours.
T o T est Thermostat WARNING: DO NOT SHORT (JUMPER) ACROSS TERMINALS OF GAS V ALVE OR SYSTEM CONTROL TO TEST OPERA TION. THIS WILL DAMAGE THE THERMOST A T AND VOID YOUR W ARRANTY . CAUTION: Do not switch system to cool if the temperature is below 50°F (10°C).
T roubleshooting SYMPTOM REMEDY 10 Thermostat does not turn on system. Check Wiring (see INST ALLA TION). Check fuse. Replace with 3 amp fuse if fuse has opened. Five minute compressor short cycle protection may be in effect. Press RESET to override. NOTE: This will erase programming.
11 R Y1 O BG E W2 LC Y2 APRILAIRE MODEL 8355 HEAT PUMP THERMOSTAT R Y O G E W2 L C W3 CARRIER LOW VOLTAGE TERMINAL BOARD APRILAIRE MODEL 8355 HEAT PUMP THERMOSTAT CONVERSION TO CARRIER SPLIT SYSTEM CO.
12 R Y1 O BG E W2 LC Y2 APRILAIRE MODEL 8355 HEAT PUMP THERMOSTAT R Y O G W1 W2 X C COMFORTMAKER LOW VOLTAGE TERMINAL BOARD APRILAIRE MODEL 8355 HEAT PUMP THERMOSTAT CONVERSION TO COMFORTMAKER CYC SER.
13 R Y1 O BG E W2 LC Y2 APRILAIRE MODEL 8355 HEAT PUMP THERMOSTAT R Y O G W2 L C PAYNE LOW VOLTAGE TERM INAL BOARD APRILAIRE MODEL 8355 HEAT PUMP THERMOSTAT CONVERSION TO PAYNE RELIANT AND ENDURA MODE.
14 R Y1 O BG E W2 LC Y2 APRILAIRE MODEL 8355 HEAT PUMP THERMOSTAT R Y O G X2 W-U B WEATHERTRON LOW VOLTAGE TERMINAL BOARD APRILAIRE MODEL 8355 HEAT PUMP THERMOSTAT CONVERSION TO WEATHERTRON HEAT PUMPS.
15 R Y1 O BG E W2 LC Y2 APRILAIRE MODEL 8355 HEAT PUMP THERMOSTAT R Y O G E W1 L C T LENNOX LOW VOLTAGE TERMINAL BOARD APRILAIRE MODEL 8355 HEAT PUMP THERMOSTAT CONVERSION TO LENNOX CB19 HEAT PUMP SYS.
Limited Warranty Y our Research Products Corporation Aprilaire ® Thermostat unit is expressly warranted for two (2) years from date of installa- tion to be free from defects in materials and workmanship.
An important point after buying a device Aprilaire 8355 (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Aprilaire 8355 yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Aprilaire 8355 - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Aprilaire 8355 you will learn all the available features of the product, as well as information on its operation. The information that you get Aprilaire 8355 will certainly help you make a decision on the purchase.
If you already are a holder of Aprilaire 8355, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Aprilaire 8355.
However, one of the most important roles played by the user manual is to help in solving problems with Aprilaire 8355. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Aprilaire 8355 along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center