Model 8100 Energy Recovery V entilator Installation Instructions READ AND SA VE THESE INSTRUCTIONS CAUTION 1. Read all instructions before beginning installation.
SPECIFICA TIONS Dimensions Unit – 37-7/16” W x 12-3/4” D x 20-9/16” H EnergyMax T ransfer Core – 12-1/8” x 12-1/8” x 10-3/4” Weight 75 lbs. Performance 77% Apparent Sensible Effectiveness (ASE) At rated ventilation capacity with 72°F indoor temperature and 32°F outdoor temperature.
SERVICE CLEARANCE 12" 12" 36" 37-7/16" 20-9/16" CEILING MOUNTING HOLES CEILING MOUNTING HOLES ON / OFF SWITCH W ALL MOUNTING HOLES W ALL MOUNTING HOLES RETURN ST ALE AIR SUPP .
The unit can be mounted on a concrete wall or on a stud wall. The mounting bracket is pre-drilled for fastening to standard 16” O.C. or 24” O.C. stud spacing. Remove the access panel, EnergyMax T ransfer Core, and air filters for installation. 1. Remove the access panel, EnergyMax T ransfer Core and filters.
MECHANICAL INST ALLA TION (CONTINUED) CEILING MOUNT The unit can be mounted on ceiling joists. The mounting bracket is pre-drilled for fastening to standard 16” O.C. or 24” O.C. ceiling joists. Remove the access panel, EnergyMax T ransfer Core, and air filters for installation.
MECHANICAL INST ALLA TION (CONTINUED) DUCTING DUCT WORK SPECIFICATIONS • Plan ontemporarily installing two airflow measuring devices. The systemwill have to be balanced( BALANCING THE SYSTEM SECTION ), after all duct work has been installed.
MECHANICAL INST ALLA TION (CONTINUED) DUCTING (CONTINUED) RETURN: FROM LIVING SPACE TO ERV • Stale airfrom the house should beexhausted from one exhaustgrille centrally located, such asa hallway .
MECHANICAL INST ALLA TION (CONTINUED) BALANCING THE SYSTEM DUCTING (CONTINUED) EQUIPMENT REQUIRED • The intakeand exhaust hoods must belocated at least 10ft. apart to avoid cross contamination. (See Figure 18 .
5 FT . MIN. 5 FT . MIN. 2-1/2 FT 2-1/2 FT PRESSURE GAUGES ST ALE AIR FROM HOUSE FRESH AIR FROM OUTSIDE FRESH AIR TO HOUSE ST ALE AIR TO OUTSIDE AIR FLOW MEASURING DEVICE #5158 AIR FLOW MEASURING DEVICE #5158 DAMPER DAMPER FIGURE 19 – Set-up for Balancing Airflow 90-1746 BALANCING THE SYSTEM (CONTINUED) BALANCING AIRFLOW 1.
SYSTEM ST ART -UP CONSTANT ON OPERATION OPERATION WITH HOME COMFORT CONTROL ™ (FIGURE 20) OPERATION WITH 8120 VENTILATION CONTROLLER OR THIRD-PARTY CONTROL (FIGURE 20) The Energy Recovery V entilator has an on/off switch which enables the unit to be constantly on.
SYSTEM ST ART -UP (CONTINUED) T able 2 – V entilation Air Requirements, CFM Home Size (ft 2 ) Number of Bedrooms < 2 2 - 3 4 - 5 6 - 7 > 7 ≤ 1500 30 45 60 75 90 1501 – 3000 45 60 75 90 105.
P.O.Box1467•Madison,WI53701-1467•Phone:800/334-6011 •Fax:608/257-4357• www.aprilairepartners.com 10009736 1.12 B2701202A Printed in U.S.A. © 2012 Aprilaire – A division of Research Products Corporation TROUBLESHOOTING T echnical Support is available Monday through Friday , 7:00 a.
An important point after buying a device Aprilaire 8100 (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Aprilaire 8100 yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Aprilaire 8100 - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Aprilaire 8100 you will learn all the available features of the product, as well as information on its operation. The information that you get Aprilaire 8100 will certainly help you make a decision on the purchase.
If you already are a holder of Aprilaire 8100, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Aprilaire 8100.
However, one of the most important roles played by the user manual is to help in solving problems with Aprilaire 8100. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Aprilaire 8100 along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center