All-In-One Wireless Security System V1.0 Model #: MG-6060 Reference and Installation Manual.
.
Paradox Magellan Systems 1 Table of Contents Introduction ......................................... .......... 3 About Mag ellan and this Manua l............. ................ 3 Convention s ............... ......................... ..................
2 Reference & Installation Manual Panel Answer O ptions ..... .......................... ............ 33 Panel Ident ifier .................... .......................... ......... 33 PC Password ...... .......................... .................
Paradox Magellan Systems 3 Introduction About Magellan and this Manual Magellan is designed for fast an d easy installation. Simply remove it from the box, mount the console and wireless transmitters, apply power and Magellan is ready to protect your home.
4 Reference & Installation Manual Quick Setup Follow these steps to quickly set up Magellan with the required settings for a basic security installation. 1. Getting Started 1. After po wering up for the first time, press [ START ] to access the Installer Menu.
Paradox Magellan Systems 5 When you are done the next menu option will appear. Pre ss [ NEXT ] until you see the “Passwords” menu or press the [8] key to immediately access the “Passwords” menu. 6. Passwords 1. From the “Passwords” menu, press [ OK ] .
6 Reference & Installation Manual Installation AC Power Magellan requires a 9Vac (1A/9VA) or 16.5Vac (20VA) transformer (not included) to supply power to the console. Connect the transformer to the AC terminals as shown in Figure 1 on page 6. Magellan can also be powered through a DC pow er supply.
Paradox Magellan Systems 7 For UL compliant ins tallations, the Magellan console must be able to seize the telephone line and p lace a call in an emergency situation. It must be ab le to do this even if other equipment (telephones, answering m achines, computer modems, etc.
8 Reference & Installation Manual Hardwire Zone Connections Magellan comes with two on-board ha rdwire zones. You can connect hardwire detecti on devices such as door contacts to Magellan’s zone terminals. Con nect the detection devices as shown in Figure 6 on page 8.
Paradox Magellan Systems 9 X10 Transmitter Connection Magellan supports the X10 communication protocol. X10 is a communication protocol for remote co ntrol of electrical devices such as lamps and appliance s. Communication is accomplished through standard household ele ctrical wiring using X10 transmitters and receivers.
10 Reference & Installation Manual Figure 12: Mounting Magellan onto the Wall Plate Figure 13: Magellan’s Back Plate Mounting Magellan on t he Wall Magellan can be mounted on a wall by first sec.
Paradox Magellan Systems 11 Programming Methods WinLoad Installer Upload/Download Software Program the Magellan console remotely or on-site using the WinLoad Installer Uploa d/Download Software for Windows® . For more information, contact your local Paradox Distributor or visit our Web site at www.
12 Reference & Installation Manual User Codes A person must be assigned to a user code in order to have access to Magellan. A user code defines the extent of a user’s access to the system and consists of a code # (PIN) and user options.
Paradox Magellan Systems 13 Zone Programming Magellan supports up to 1 6 wireless zones where each zone can be configured wi th a different zone d efinition and option. Each zone can also have a voice label recorded for it. Magel lan’s zones can be programmed using section programming or through the Installer me nu.
14 Reference & Installation Manual Follow/Stay Zones Sections [001] to [016]: Zones 1 to 16, 3-digit # = 004 Follow/Stay zones function as follows: • All zones defined a s Follow/Stay zones become Follow zones (refer to Follow Zones on page 13) when the Magellan system is Regular armed.
Paradox Magellan Systems 15 24Hr. Gas Zones Sections [001] to [016]: Zones 1 to 16, 3-digit # = 012 When a 24Hr. Gas zone opens, whe ther it is armed or disarmed, the console will immediately generate an al arm. The SIA FSK reporting format incl udes specific report codes to identify the alarm as a Gas alarm.
16 Reference & Installation Manual Intellizone Delay Timer Section [065]: 010 to 255 seconds; Default = 48 seconds Enter the desired 3-digit value into secti on [065] to program the Intellizone Delay Timer.
Paradox Magellan Systems 17 Wireless Programming The Magellan system supports up to 16 wireless zones and two wireless doorbells. These wireless zones are monitored usin g transmitters such as wireless detectors and door contacts. The Magellan console on ly supports the Paradox Mage llan series of wireless transmitters.
18 Reference & Installation Manual The signal strength is displayed using two terms: • “Good”: This is an average reading and is acceptabl e. • “Weak”: This is the wea kest reading. The transmitter should be moved to another location. Sometimes moving the transmitter by a small amount will greatly increase the signal reception.
Paradox Magellan Systems 19 Figure 20: Remote Control Button Options * = Hexa values A to F are keys [1] to [6] from Magellan’s Center Keypad. † = The panic feature (section [091] options [1] to [3] ; see page 23) must be enabled in order for this to work.
20 Reference & Installation Manual Arming and Disarming Regular Arming Switches to Stay Arming Section [092]: Option [4] Option [4] OFF = Switch to Stay arming disabled (default) Option [4] ON = S.
Paradox Magellan Systems 21 One-Touch Arming Section [092]: Options [7] and [8] Option [7] OFF = One-touch Reg ular/Force arming disabled Option [7] ON = One-touch Regular/Force arming enable d (defau.
22 Reference & Installation Manual Alarm Options Bell Cut-off Timer Section [063]: 001 to 255 minutes; 000 = Disabled; Defau lt = 4 minutes After an audible alarm, th e siren will stop upon disarming of the system or when the Bell Cut-Off timer has elapsed, whichever comes first.
Paradox Magellan Systems 23 presence and functionality. If a device has not sent a signal within the specified time period, Magellan can generate a trouble, an alarm and/or transmit a report code to the central monitoring station as define d by the Wireless Transmitter Supervision Options (pag e 22).
24 Reference & Installation Manual Reporting and Dialer Settings Report Codes A report code is a 1- or 2-digit hexa decimal value consisting of digits from 1 to F. Each section from [120] to [156] represents a set of up to four specific events and each of these events ca n be programmed with a separate 1- or 2-digit report code.
Paradox Magellan Systems 25 • Auxiliary Panic: Panic keys [4] and [6] (page 23) or the appropriate button (s) on a remote control (page 18) have been pressed. • Fire Panic: Panic keys [7] and [9] (page 23) or the appropriate button (s) on a remote control (page 18) have been pressed.
26 Reference & Installation Manual Table 8: Special Keys for Telephone Numbers Central Station Telephone Numbers (CSTNs ) Section [111] = Central Station Tel ephone Number 1 Section [112] = Centra.
Paradox Magellan Systems 27 [0] key followed by the 3-digit account number. Also, when using 3-digit account numbers, you must use 1-digit report codes.
28 Reference & Installation Manual Delay Between Dialing Attempts Section [076]: 001 to 255 seconds; 000 = disabled ; Default = 20 seconds This delay determines the amount of time the Magellan console will wait between each dialing attempt.
Paradox Magellan Systems 29 Auto-Test Report Section [071]: 001 to 255 days; 000 = Disab led; Default = Disabled Section [084]: Time (HH:MM) The Magellan conso le will transmit the Test Report report code programmed into section [153] after the nu mber of days programmed into section [071] has elapsed at th e time programmed into section [084].
30 Reference & Installation Manual Programmable Outputs A PGM is a programmable output that toggles to its oppo site state (i.e. a normally open PGM will close) when a specific event has occurred in the system. For example, a PGM can be used to activate bells or strobe li ghts, open/close garage doors a nd much more.
Paradox Magellan Systems 31 System Settings Software Reset Section [201] Performing a software reset will reset all programmed sections back to the factory defaults. To perform a software reset: 1. Access the installer prog ramming mode (page 11). 2. Enter section [201].
32 Reference & Installation Manual AC Failure Power failure detected. The system is running on the backup battery pack. Supervision Trouble Zo ne(s) displayed have not sent a check-in signal within the programmed interval (page 22). Console Tamper The Magellan console was tampered with.
Paradox Magellan Systems 33 WinLoad Software Settings Panel Answer Options The following two options define ho w Magellan answers an incoming call from a computer using the WinLoad Installer Upload/Download Software.
34 Reference & Installation Manual Appendix 1: Ademco Contact ID Report Code List CID# Reporting Code Programming Value Medical Alarms - 100 100 Medical alarm 01 101 Pendant transmitter 02 102 Fai.
Paradox Magellan Systems 35 CID# Re porting Code Programming Value 335 Local printer paper out 54 336 Local printer failure 55 337 Expansion module DC loss 56 338 Expansion module low battery 57 339 E.
36 Reference & Installation Manual CID# Reporting Code Programming Value 525 Reversing relay disabled AE 526 Notification appliance chk. #3 disabled AF 527 Notification appliance chk.
Paradox Magellan Systems 37 Index Numerics 001 to 016 ............................. .......................... ....... 13 – 16 021 to 036 ............................. .......................... ..............17 041 to 056 ..........................
38 Reference & Installation Manual Answering machine override ........ .......................... ....... 33 Arming options Auto-arm options ............... .......................... .............. 2 0 Bell Squawk on Arm/Di sarm with Remote Control .
Paradox Magellan Systems 39 E Entry Delay 1 ................... ............ .......................... ........13 Entry Delay 2 ................... ............ .......................... ........13 EOL zones ................... .....................
40 Reference & Installation Manual Special d isarming .............. .......................... .............. 2 4 System trouble ............... .......................... ................. 25 System trouble restore .............. ...............
Paradox Magellan Systems 41 V Viewing .................. ................................................ ........ 17 Viewing transmitter sig nal strength .......... ............. ........17 Voice message repetitions .......... .......................
42 Reference & Installation Manual.
Paradox Magellan Systems 43 WARRANTY Paradox Security Systems Ltd. (“Seller”) warrants its products to be free from defects in materials and workmanship under normal use for a period of one year.
.
.
780 Industriel Blvd., Sai nt-Eustache (Quebec) J7R 5V3 CANADA Tel.: (450) 491-7 444 Fax: (450) 491-73 13 www.paradox.ca Printed in Canada - 09/2004 MAGELLAN-EI01.
An important point after buying a device Magellan MG-6060 (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Magellan MG-6060 yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Magellan MG-6060 - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Magellan MG-6060 you will learn all the available features of the product, as well as information on its operation. The information that you get Magellan MG-6060 will certainly help you make a decision on the purchase.
If you already are a holder of Magellan MG-6060, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Magellan MG-6060.
However, one of the most important roles played by the user manual is to help in solving problems with Magellan MG-6060. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Magellan MG-6060 along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center