DYNA-GLAS TM CENTRIFUGAL PUMPS WITH INTEGRAL TRAP O W N E R’ S M A N U A L INST ALLA TION, OPERA TION & P ARTS 5MPRA Series MODELS 5MPRA6C-146 5MPRA6C3-146 5MPRA6D-147 5MPRA6D3-147 5MPRA6E-148 5MPRA6E3-148 5MPRA6F-156 5MPRA6F3-156 STA-RITE FOREIGN SALES CORP.
2 ‘5MPRA ’ SERIES PUMP WITH TRAP To avoid unneeded service calls, prevent possible injuries, and get the most out of your pump, READ THIS MANUAL CAREFULLY! The Sta-Rite ‘5MPRA’ Series Self-priming Centrifugal pump: • Is designed for use with swimming pools or as a centrifugal pump.
3 READ AND FOLLOW ALL INSTRUCTIONS! This is the safety alert symbol. When you see this symbol on your system or in this manual, look for one of the following signal words and be alert to the potential for personal injury. warns about hazards that will cause death, serious personal injury, or major property damage if ignored.
4 INST ALL A TION Only qualified, licensed personnel should install pump and wiring. Pump mount must: Be solid - Level - Rigid - Vibration free. (To reduce vibration and pipe stress, bolt pump to mount.) Allow pump suction inlet height to be as close to water level as possible.
5 Piping: Use at least 1-1/2" (38mm) pipe (use 2"(51mm) pipe if possible). Increase size if a long run is needed. When using 1-1/2" pipe, connect to pump with 1-1/2" to 2" (38 to 51mm) reducing adapter. To avoid strains on the pump, support both suction and discharge pipes inde- pendently.
6 ELECTRICAL Ground motor before connecting to electrical power supply. Failure to ground motor can cause severe or fatal electrical shock hazard. Do not ground to a gas supply line. To avoid dangerous or fatal electrical shock, turn OFF power to motor before working on electrical connections.
7 OPERA TION NOTICE: NEVER run pump dry. Running pump dry may damage seals, caus- ing leakage and flooding. Fill pump with water before starting motor. Before removing trap cover: 1. STOP PUMP before proceeding. 2. CLOSE GATE VALVES in suction and discharge pipes.
8 Drain all water from pump and piping when expecting freezing temperatures or when storing pump for a long time (see instructions below). Keep motor dry and covered during storage. To avoid condensation/corrosion problems, do not cover pump with plastic.
9 PUMP SER VICE Pump should only be serviced by qualified personnel. Be sure to prime pump (Pg. 7) before starting. Before removing trap cover: 1. STOP PUMP before proceeding. 2. CLOSE GA TE V ALVES in suction and discharge pipes. 3. RELEASE ALL PRESSURE from pump and piping system.
10 Pump Reassembly/Installing New Seal 1. Ceramic seat must be clean and free of dirt, grease, dust, etc. Wet outer edge with small amount of liquid detergent; press ceramic seat into seal plate cavity firmly and squarely with finger pressure (Fig. 6).
11 Clogged pipe/trap/impeller, worn impeller: 7. Make sure suction trap is not clogged; if it is, clean trap and strainer. 8. Make sure impeller is not clogged (follow steps 1 through 7 under “Removing Old Seal”, Page 9; check impeller for clogging; follow steps 7 through 11 under “Installing New Seal”, Page 10, for reassembly).
1 2 3 4 5 6 7 8 8A 8B Box A Box A 11 12 13 14 15B 15A 16 17 18 19 20 21 22 23 9 10 012 0394 BOX A For quick disconnect pipe connection parts: Adapter Union Pkg ..................... 11201-0153 O-Rings (2) .................... 35505- 1318 Key Part No. Description Qty.
An important point after buying a device Mad Catz 5MPRA6E-148 (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Mad Catz 5MPRA6E-148 yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Mad Catz 5MPRA6E-148 - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Mad Catz 5MPRA6E-148 you will learn all the available features of the product, as well as information on its operation. The information that you get Mad Catz 5MPRA6E-148 will certainly help you make a decision on the purchase.
If you already are a holder of Mad Catz 5MPRA6E-148, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Mad Catz 5MPRA6E-148.
However, one of the most important roles played by the user manual is to help in solving problems with Mad Catz 5MPRA6E-148. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Mad Catz 5MPRA6E-148 along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center