Instruction/ maintenance manual of the product MPB-33 Lucent Technologies
Go to page of 28
HOMEOWNER'S CARE AND OPERA TION INSTRUCTIONS OTL Report No. 116-F-36-5 B-VENT MPB-33/35/40/45 SERIES MODELS A French manual is available upon request. Order P/N 875,031CF Ce manuel d’installation est disponible en francais, simplement en faire la demande.
2 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. A VERTISSEMENT Ne pas se servir de cet appareil s'il a été plongé dans l'eau, complètement ou en partie. Appeler un technicien qualifi é pour inspecter l'appareil et rem- placer toute partie du système de contrôle et toute commande qui ont été plongés dans l'eau.
3 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. CONGRA TULA TIONS! In selecting this Lennox B-Vent Gas Appliance you have chosen the fi nest and most dependable fi replace to be found anywhere. A beautiful, prestigious, alternative to a wood burning fi replace.
4 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. Variable Flame Height Adjustment ( Millivolt Appliances only) 1. All Millivolt appliances are equipped with a variable gas control valve. Flame height for these models may be adjusted through a range between fi xed low and high settings, alternately , while the appliance is in operation.
5 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. 3. Keep lower control compartment clean by vacuuming or brushing at least twice a year . More frequent cleaning may be required due to excessive lint from carpeting, bedding materials, etc.
6 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. 6 - If the smoke is not drawn towards the edges of the glass door turn off the appliance and call a qualifi ed ser vice technican. Manual-Reset Safety Limit Switch This appliance is equipped with a manual reset blocked fl ue safety limit switch.
7 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. MAINTENANCE T ASK ACCOMPLISHING PERSON PROCEDURE Inspecting/Cleaning Burner , Logs and Controls Qualifi ed Ser vice T echnician Inspect valve and ensure it is properly operating. Check piping for leaks.
8 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. T o install the front glass enclosure panel, proceed as follows: 1. Retrieve the glass door frame. Visually inspect the gasket on the backside of the panel. The gasket surface must be clean, free of irregularities and seated fi rmly .
9 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. Electronic Appliance Checkout T o light the burner , refer to the lighting instruc- tions on Page s 20 and 21 . Ensure the igniter lights the pilot. The pilot fl ame should engulf the fl ame sensor as shown in Figure 9.
10 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. Figure 10 Figure 11 Figure 12 Burner Flame Appearance - Model MPB-3328 Burner Flame Appearance - Model MPB-3530 Burner Flame Appearance - Model MPB-4035 & MPB-4540 Initial Installation Considerations The packaged logs are located within the fi rebox.
11 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. Glowing Embers, Vermiculite, Decorative V olcanic Stone And Log Placement Instructions: Step 1. Separate the Glowing Embers (Rockwool) into pieces about the size of a quarter (see Figure 13) . Keep the pieces fl uffed up, not matted.
12 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. MPB-3328 LOG PLACEMENT 1 Position the individual logs as shown below . Logs should be placed in the order shown. Position the rear log on the brackets at the rear of the fi rebox with the log's notches directly over the brackets.
13 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. MPB-3530 LOG PLACEMENT 1 Position the individual logs as shown below . Logs should be placed in the order shown. Position the rear log on the brackets at the rear of the fi rebox with the log's notches directly over the brackets.
14 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. MPB-4035 & MPB-4540 LOG PLACEMENT 1 Position the individual logs as shown below . Logs should be placed in the order shown. Position the center log on the burner fi rst, then place the glowing embers as shown in Fig- ure 15.
15 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. WIRING DIAGRAMS Wiring diagrams are provided here for reference purposes only . This information is also provided on schematics attached directly to the appliance on a pullout panel located within the control compartment.
16 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. Remote Control Kit, Standard Cat. No. Model No. Description H0249 RCL Remote Control System (Standard) Rocker Switch Kit Cat. No. Model No. Description 80L41 FRS Rocker Switch Kit Forced Air Blower Kits Cat.
17 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. Arch Door Kit - Polished Brass Cat. No. Model Models-Where Used 98L05 ADK33CPB MPB-3328 26M43 ADK35CMPB MPB-3530 81L35 ADK40CPB MPB-4035 81L36 ADK45CPB MPB-4540 Arch Door Kit - Brushed Stainless Steel Cat.
18 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. ARCH DESIGN SCREEN DOOR KITS Cat. No. Model Description Where Used H0858 AD35C 35” Arch Doors, Charcoal MPB3530 H0859 AD35TI 35” Arch Doors.
19 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. Decorative Arch Screen Panel Kit Cat. No. Model Model H3592 DASPK33TI 33” Dec. Arch Screen Panel H3593 DASPK35TI 35” Dec.
20 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. LIGHTING INSTRUCTIONS – SIT MILLIVOL T GAS VAL VE WARNING: IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTL Y , A FIRE OR EXPLOSION MA Y RESUL T CAUSING PROPERTY DAMAGE, PERSONAL INJUR Y OR LOSS OF LIFE.
21 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. INSTRUCTIONS D’ALLUMAGE – VANNE GAZ MILLIVOLT SIT INSTRUCTIONS D'ALLUMAGE 8. Enfoncez le bouton de réglage jusqu’au fond et gardez-le enfoncé.
22 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. WARNING: IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTL Y , A FIRE OR EXPLOSION MA Y RESUL T CAUSING PROPERTY DAMAGE, PERSONAL INJUR Y OR LOSS OF LIFE. A. When lighting the appliance, follow these instructions exactly .
23 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. INSTRUCTIONS D’ALLUMAGE — ELECTRONIC INSTRUCTIONS D’ALLUMAGE POUR VOTRE SÉCURITÉ, LISEZ CES INSTRUCTIONS AVANT L ’ALLUMAGE A. Lorsque vous allumez l’appareil, suivez exactement ces instruc- tions.
24 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. TROUBLESHOOTING GUIDE - MILLIVOL T GAS CONTROL SYSTEM Note: Before troubleshooting the gas control system, Ensure external gas shut off valve, located at gas supply inlet, (and wall switch, iff applicable), is in the “ON” position.
25 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. ST ART CHECK • T urn Off Gas Supply . • Ensure Valve Switch Is In ON Position. • Disconnect Control Harness. • T urn On Optional Remote Switch (if applicable) • Check for proper volt- age at control harness (see insert A).
26 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. Item # Description MPB-3328 MPB-3530 MPB-4035 MPB-4540 Part No. Qty. Part No. Qty . Part No. Qty.
27 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. REPLACEMENT P AR TS 4 7 1 2 5 40 13 12 42 3 8 9 40/45 14 15 9 33/35 20 21 10 40/45 33/35 10 23 22 26 24 25 27 41 43 44 14 Located Inside (see F.
Printed in U.S.A. © 2005 by LENNOX HEARTH PRODUCTS P/N 875,031M REV . B 05/2006 Lennox Hearth Products reserves the right to make changes at any time, without notice, in design, materials, specifi cations, prices and also to discontinue colors, styles and products.
An important point after buying a device Lucent Technologies MPB-33 (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Lucent Technologies MPB-33 yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Lucent Technologies MPB-33 - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Lucent Technologies MPB-33 you will learn all the available features of the product, as well as information on its operation. The information that you get Lucent Technologies MPB-33 will certainly help you make a decision on the purchase.
If you already are a holder of Lucent Technologies MPB-33, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Lucent Technologies MPB-33.
However, one of the most important roles played by the user manual is to help in solving problems with Lucent Technologies MPB-33. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Lucent Technologies MPB-33 along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center