NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 1 48" Wood Burning Fireplaces P/N 850,006M REV. C 04/2004 EST -48 EST -48-H MODELS WH Report No. 629-915173 EST A TE SERIES This installation manual will enable you to obtain a safe, efficient and dependable installation of your fireplace system.
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 2 TABLE OF CONTENTS Safety Rules .................................... page 2 Tools and Building Supplies ............ page 2 Precautions ..................................... page 3 Introduction .......
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 3 Figure 1 TYPICAL INSTALLATION *Construction Materials: • framing materials • paneling • particle board • flooring • millboard • dry wall • plywood • etc. PRECAUTIONS Note: These fireplace systems are not difficult to install.
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 4 WARNING: IF INSULATION IS USED, THE FIREPLACE MUST NOT BE PLACED DI- RECTLY AGAINST IT. INSULATION OR VAPOR BARRIERS, IF USED, MUST FIRST BE COVERED WITH GYPSUM BOARD, PLYWOOD, PARTICLE BOARD OR OTHER MATERIAL TO ASSURE INSULATION AND VAPOR BARRIERS REMAIN IN PLACE.
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 5 Figure 5 Figure 7 Figure 6 The fireplace may be positioned and then the framing built around it, or the framing may be constructed and the fireplace positioned into the opening. Usually, no special floor support is needed for the fireplace, however, to be certain: 1.
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 6 Figure 10 IMPORTANT: UNDER NO CIRCUMSTANCES CAN THE FIREPLACE TOP SPACERS ( FIGURE 10 ) BE REMOVED OR MODIFIED, NOR MAY YOU NOTCH THE HEADER TO FIT AROUND OR BE INSTALLED LOWER THAN THE SPACERS. THE HEADER MAY BE IN DIRECT CONTACT WITH THE TOP SPACERS BUT MAY NOT BE SUPPORTED BY THEM.
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 7 FRAMING SPECIFICATIONS Figure 11 Figure 12 Framing Dimensions for Ceiling Flue Type A B FTF13 Vertical 19" 19" (483 mm) (483 mm) FTF13 19&q.
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 8 Firestop Spacer Room Above Firestop Spacer Attic Above F10FS30-2 Firestop Spacer FTF10-S4 Stabilizer 2" Min. Air Space 30 ° Firestop And Attic Above 10' Max. Attic Space 2" Min. Air Space F10FS30-2 Firestop Spacer FTF10-S4 Stabilizer 30 ° Firestop And Room Above 10' Max.
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 9 Step 4. Note: Chimney sections are constructed with a unique locking tab design, which en- sures an immediate, tight assembly between sections. Plan your chimney requirements care- fully before assembly as chimney is difficult to disassemble after installation.
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 10 Locking Band Mastic Figure 30 Step 9. Security Chimneys locking bands, Model FLB, may be required if the chimney extends too high above the roof flashing.
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 11 A ¹⁄₈ " diameter hole must be drilled in the chimney joint using a ¹⁄₈ " diameter drill. Hole should be drilled in center of joint overlap ( see Figure 38 ). Be sure to drill only through the outer chimney casting.
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 12 FTF13 VERTICAL ELEVATION CHART 11 0 11 1 0 0 279 0.28 17 1 5 0 1 0 432 0.43 21 ¹⁄₄ 19 ¹⁄₄ 2 0 0 540 0.54 27 ¹⁄₄ 23 ¹⁄₄ 1 1 0 692 0.69 33 ¹⁄₄ 29 ¹⁄₄ 0 2 0 845 0.85 35 2 11 0 0 1 889 0.
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 13 Figure 36 A 1 C 1 B 1 B 2 C 2 A 2 A 1 C 1 B 1 B 2 C 2 A 2 Figure 37 Chimney Section Joints No. 8 x 1/2" SMS Screws Required At Every Joint Past.
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 14 Step 3. Center outer-locking section over outer chimney pipe. Push down until locking joint has firmly engaged. Step 4. Pull up slightly on return elbow to ensure locking joint has firmly engaged. Step 5.
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 15 OPTIONAL EQUIPMENT CONSIDERATIONS Gas Line Connection The EST-48 has been listed to accept a ¹⁄₂ " gas line for an approved gas appliance. Always have the appliance installed in accordance with all local building codes.
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 16 Figure 45 Figure 44 A B D C C Hearth Extensions and Wall Shields A hearth extension must be installed with all fireplaces. It is to protect the floor in front of the fireplace from both radiant heat and sparks.
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 17 Figure 47 FINISH TO YOUR TASTE There are a wide variety of “ finished looks ” for these fireplaces, from formal wall decor with elaborate mantels to rustic wood paneling or warm brick facings. Only noncombustible materials like stone, tile, brick, etc.
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 18 63L19 FTF13-12 63L20 FTF13-18 Chimney Section 63L21 FTF13-36 63L40 F10F6 Flashing 63L41 F10F12 Round Termination 63L44 FTF13-CTD Firestop Spacer (Fl.
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 19.
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 20 Lennox Hearth Products reserves the right to make changes at any time, without notice, in design, materials, specifications, prices and also to discontinue colors, styles and products. Consult your local distributor for fireplace code information.
An important point after buying a device Lucent Technologies EST-48 (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Lucent Technologies EST-48 yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Lucent Technologies EST-48 - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Lucent Technologies EST-48 you will learn all the available features of the product, as well as information on its operation. The information that you get Lucent Technologies EST-48 will certainly help you make a decision on the purchase.
If you already are a holder of Lucent Technologies EST-48, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Lucent Technologies EST-48.
However, one of the most important roles played by the user manual is to help in solving problems with Lucent Technologies EST-48. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Lucent Technologies EST-48 along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center