Instruction/ maintenance manual of the product VC201A-H Louisville Tin and Stove
Go to page of 18
Gas-Fir ed V ented Room Heater INST ALLA TION AND OPERA TING INSTRUCTIONS P/N 80900-H - REV . 01/05 This appliance is equipped with a safety control system designed to protect against improper venting of combustion products. THIS UNIT IS NOT TO BE INST ALLED IN MOBILE HOMES.
SPECIFICA TIONS………………………. 2 INTRODUCTION……………………….. 3 VENTING………………………………... 3 , 4 GAS SUPPL Y……………………………. 5 LOCA TION & SPECIAL PRECAUTIONS 5 COMBUSTION & VENTILA TION AIR.
INTRODUCTION THIS IS A GAS-FIRED, GRA VITY VENTED ROOM HEA TER THA T WILL OPERA TE SAFEL Y AND PROVIDE AN EFFICIENT SOURCE OF HEA T WHEN INST ALLED, OPERA TED AND MAINT AINED AS RECOMMENDED IN THESE INST ALLA TION AND OPERA TING INSTRUCTIONS. READ THESE INSTRCTIONS THOROUGHL Y BEFORE INST ALLING, SER VICING, OR USING THIS APPLIANCE.
VENTING 10’ or Less 2’ Min. 3’ Min. Ridge Chimney More than 10’ 10’ 2’ Min. 3’ Min. Ridge Chimney Height above any roof surface withon 10’ horizontally FIGURE A FIGURE A Seal around co.
GAS SUPPL Y This vented room heater must be connected to a gas supply capable of supplying the appliances full rated capacity . Provide a 1/8 inch N.P .T . plugged tapping, accessible for test gauge connection, immediately upstream of the gas supply connection to the appliance.
COMBUSTION AND VENTILA TION AIR When installed, this gas appliance must be provided with fresh air for combustion, ventilation, and dilution of hot flue gases. The minimum required volume of the area where the appliance is installed should be 50 cubic feet per 1,000 btu/hr .
CLEARANCES If the area where the appliance is to be installed contains carpeting, tile, or combustible materials, other than wood flooring, the appliance shall be installed on a metal plate (stoveboard), a wood panel, or other non-combustible materials.
PILOT ADJUSTMENT The pilot flame can be observed by opening the pilot lighting hole cover . The pilot flame should surround the top 3/8 to ½ inch of the thermocouple (see Figure 2). If the flame needs adjusting, first locate the pilot adjustment screw cap and remove.
CAUTION: There may be momentary and spasmodic orange flashes in the flame. This is caused by the burning of air borne dust particles and is not to be confused with the yellow tipping which is a stable or permanent situation when there is insufficient primary air .
10. Close pilot lighting hole cover and casing door . 11. Turn gas control knob counterclockwise to “ON”. 12. Turn temperature control knob to desired setting.
Flame too large 1. Defective operator section of gas valve. 1. Replace complete valve. 2. Burner orifice too large. 2. See orifice chart to determine the correct orifice size for your Model Number and elevation. 3. Pressure regulator malfunction. 3. Regulator must be adjusted by a qualified serviceman using proper tools and instruments.
Not enough heat 1. Heater undersized. 1. This is especially true when a dwelling or room is enlarged. Have the heat loss calculated and compare to the heater output (70% of input). Y our gas company or installer can supply you with this information. If heater is undersized, replace with correct size unit.
Page 13 Heat Shield Junction Box Speed Control Power Cord Fan Switch Bracket Blower Housing Mounting T ab FIGURE A CHB-3 BLOWER INST ALLA TION - (OPTIONAL) (ST ANDARD ON 70,000 BTU UNITS ONL Y) STEP 1. Run black wire and white wire that comes from bottom of junction box down through the heat shield.
TSK W ALL ST A T KIT OPTIONAL (VC/VCR- H SERIES HEA TERS) W ALL THERMOST A T INST ALLA TION INSTRUCTIONS Y our heater can be re-wired to operate with a millivolt wall thermostat by your installer . See wiring diagram below for correct wiring. NOTE: Do not disconnect the wire from the blocked flue switch to the “TH” terminal on the gas valve.
MODELS INCLUDED: VC-H / Closed Front Circulators VCR-H / Radiant Front Circulators CHB3 Blower VENTED CONSOLE HEA TER Prices and specifications subject to change without notice. All prices are F .O.B. factory . NOTICE: When ordering any component in the control train assembly , specify either Honeywell or Robertshaw components.
NA T . VC201A-H VC / VCR351A-H VC / VC R501A-H VC / VCR701A-H MODEL NUMBER L. P . VC202A-H VC / VCR352A-H VC / VC R502A-H VC / VCR702A-H REF . P A RT LIST P A RT LIST P AR T LIST P A R T LIST P ART DESCRIPTION NO. NO. PRICE NO. PRICE NO. PRICE NO. PRICE V alve, VS821A1061 Honeywell, Nat.
IMPOR T ANT SAFETY BULLETIN ON YOUR GAS CONTROL AND PILOT LIGHT SYSTEM FOR HEA TING EQUIPMENT WHA T YOU DON’T KNOW CAN HUR T YOU. Y our pilot light system has been designed for safe and reliable operation. Although safety mechanisms are built-in, the potential for hazard exists.
The Louisville Tin & Stove Co. warrants to the original user the accompanying product for the period specified herein, provided said product is installed, operated, maintained, serviced, and used according to the instructions and specifications accompanying the product.
An important point after buying a device Louisville Tin and Stove VC201A-H (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Louisville Tin and Stove VC201A-H yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Louisville Tin and Stove VC201A-H - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Louisville Tin and Stove VC201A-H you will learn all the available features of the product, as well as information on its operation. The information that you get Louisville Tin and Stove VC201A-H will certainly help you make a decision on the purchase.
If you already are a holder of Louisville Tin and Stove VC201A-H, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Louisville Tin and Stove VC201A-H.
However, one of the most important roles played by the user manual is to help in solving problems with Louisville Tin and Stove VC201A-H. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Louisville Tin and Stove VC201A-H along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center