Instruction/ maintenance manual of the product RPV-I&S Lochinvar
Go to page of 16
1 RPV-I&S POWERED VENT GAS WATER HEATER For your family’s comfort, safety and convenience we recommend water heaters to be installed and serviced by a plumbing professional. T ABLE OF CONTENTS GENERAL INFORMATION ................................
2 RPV-I&S INSTALLATION Locating The Water Heater DO NOT install the water heater in any location where gasoline or flammable vapors are likely to be present.
3 RPV-I&S 76,000 BTU (283.9 L - 22.3 kW/Hr) models. Part II will cover venting specifications for 40 Gal - 40,000 BTU (151.4 L - 11.7 kW/ Hr) and 48 gal - 40,000 BTU (181.7 L - 11.7 kW/Hr) models. Refer to the rating plate located on the water heater for correct model identification.
4 RPV-I&S diameter PVC pipe. When venting with 4" (10.2 cm) PVC, use a 4" (10.2 cm) to 3" (7.6 cm) reducer to exit through the building wall with 3" (7.6 cm) PVC. Use the 3" (7.6 cm) vent terminal supplied with the water heater to terminate on the outside of the building.
5 RPV-I&S NOTE: For installations requiring both horizontal and vertical runs, the following rule must be followed: Total number of feet of straight pipe (both horizontally and vertically) must not exceed the allowable length listed in the “Through The Wall” section of the table for total number of elbows used.
6 RPV-I&S NOTE: When using 3" (7.6 cm) PVC, use a 3" (7.6 cm) to 2" (5.1 cm) reducer and exit the building wall with 2" (5.1 cm) PVC using the 2" (5.1 cm) 45° vent terminal supplied. Two 45° elbows are equivalent to one 90° elbow.
7 RPV-I&S NOTE: For installations requiring both horizontal and vertical runs, the following rule must be followed: Total number of feet of straight pipe (both horizontally and vertically) must not exceed the allowable length listed in the “Through The Wall” section of the table for total number of elbows used.
8 RPV-I&S 1. When directly communicating with the outdoors, each opening must have a minimum free area of 1 square inch per 4000 BTU (6.5 cm 2 /1.2 kw) per hour of total input rating of all equipment in the enclosure.
9 RPV-I&S GAS CONNECTIONS The gas supply lines must meet all requirements of the National Fuel Gas Code ANSI Z223.1-(Latest Edition) and/or in Canada CAN/CGA B149 Installation Codes - (Latest Editions). The minimum permissible gas supply pressure for the purpose of input adjustment is 1.
10 RPV-I&S Figure 11.
11 RPV-I&S Figure 12.
12 RPV-I&S THERMOST A T ADJUSTMENT The thermostat dial is adjusted to approximately 120°F when shipped from the factory. When adjusting the thermostat, it should be remembered that lower temperature settings are more energy efficient. The thermostat cover, on the right side of the gas valve, must be removed when the thermostat is adjusted.
13 RPV-I&S MAINTENANCE The following maintenance should be performed by a qualified service technician at the minimum periodic intervals suggested below. In some installations, the maintenance interval may be more frequent depending on the amount of use and the operating conditions of the water heater.
14 RPV-I&S THE FOLLOWING INSTRUCTIONS ARE FOR INSTALLATION OF: GAS WATER HEATERS SUITABLE FOR WATER (POTABLE) HEATING AND SPACE HEATING 1. All piping components connected to this water heater for space heating applications must be suitable for use with potable water.
15 RPV-I&S VENT PIPE PREPARATION AND JOINING Most failures in PVC, CPVC or ABS systems result from improper preparation and joining of pipe and fittings.
16 RPV-I&S Printed in USA.
An important point after buying a device Lochinvar RPV-I&S (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Lochinvar RPV-I&S yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Lochinvar RPV-I&S - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Lochinvar RPV-I&S you will learn all the available features of the product, as well as information on its operation. The information that you get Lochinvar RPV-I&S will certainly help you make a decision on the purchase.
If you already are a holder of Lochinvar RPV-I&S, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Lochinvar RPV-I&S.
However, one of the most important roles played by the user manual is to help in solving problems with Lochinvar RPV-I&S. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Lochinvar RPV-I&S along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center