Instruction/ maintenance manual of the product LRA Linear
Go to page of 28
LRA Linear Residential Actuator Installation Guide PRINTER’S INSTRUCTIONS: INSTR,INSTL,LRA - LINEAR P/N: 228158 X12 - INK: BLACK - MA TERIAL: 20 LB. MEAD BOND - SIZE: 8.
LRA Linear Residential Actuator Installation Guide - 2 - 228158 Revision X13 2-3-2009 T able of Contents Pre-installation Information .................................. 1 B e f o r e Y o u B e g i n . . . ...................................... 1 Alwa ys Check the Gate’ s Action .
LRA Linear Residential Actuator Installation Guide - 1 - 228158 Revision X13 2-3-2009 Pre-installation Information Before Y ou Begin... Bef ore unpac king, inspect the carton for e xterior damage. If you find damage, advise the deliv er y carrier of a potential claim.
LRA Linear Residential Actuator Installation Guide - 2 - 228158 Revision X13 2-3-2009 Linear Actuator Operator Overview The Model LRA Residential Linear Actuator is designed to open and close a light-duty residential s wing gate. The operator can be used in left-hand or right-hand swing gate installations on gates weighing up to 600 pounds .
LRA Linear Residential Actuator Installation Guide - 3 - 228158 Revision X13 2-3-2009 Gate Lay out Illustration ENTR Y GATE FULLY CLOSED GATE FULLY OPEN LEAVE SLAC K IN CABLE TO ALLOW F O R GATE SWIN .
LRA Linear Residential Actuator Installation Guide - 4 - 228158 Revision X13 2-3-2009 Mounting Brack et Installation Examine Figure 2 f or details of the required mounting locations f or the two brack ets.
LRA Linear Residential Actuator Installation Guide - 5 - 228158 Revision X13 2-3-2009 Operator Setup Operator Mounting The operator mounts on the post brack et pin and into the gate brac ket b ushing. Refer to Figure 5. With the gate closed, carefully position the operator over the mounting 1.
LRA Linear Residential Actuator Installation Guide - 6 - 228158 Revision X13 2-3-2009 Operator Setup (Continued) Limit Switch Adjustment The open and close limit switches are adjustable by sliding them on the operator’ s frame . Sliding either s witch closer to the center of the operator decreases the gate tra vel.
LRA Linear Residential Actuator Installation Guide - 7 - 228158 Revision X13 2-3-2009 Controller Features SHADOW/RESET PROGRAMMING BUTTONS POWE R INDICATORS DISPLAY WHIP ANTENNA OPERATION BUTTONS OPER.
LRA Linear Residential Actuator Installation Guide - 8 - 228158 Revision X13 2-3-2009 Indicator Descriptions INDICA T OR DEFINITION INDICA TION WHEN LIT DURING NORMAL OPERA TION INDICA TION WHEN LIT D.
LRA Linear Residential Actuator Installation Guide - 9 - 228158 Revision X13 2-3-2009 T erminal Descriptions TERMINAL GROUP FUNCTION A C N 24 VOL T INPUT F ACT OR Y CONNECTED TO 24 V AC FR OM TRANSFORMER OR 24 VDC FROM CONTINUOUS DUTY DC SUPPL Y . AC DC - A CCESSOR Y POWER PRO VIDES 24 VOL T DC POWER FOR A CCESSORIES.
LRA Linear Residential Actuator Installation Guide - 10 - 228158 Revision X13 2-3-2009 Operator Accessor y Connections 3-BUTTON ST ATIO N KEYSWITC H FIRE ACCESS SWITCH SINGLE-CHAN NEL RADIO RECEIVER W.
LRA Linear Residential Actuator Installation Guide - 11 - 228158 Revision X13 2-3-2009 Basic Controller Programming Progr amming Overview The Controller can be programmed with v arious options for the operator . The programming fields are defined as “functions” that hav e “options”.
LRA Linear Residential Actuator Installation Guide - 12 - 228158 Revision X13 2-3-2009 Basic Controller Programming (Cont.) Run Alarm and Pre-start Alarm The f actor y def ault is Run Alarm on and a 3-second Pre-star t Alarm. The operator’ s beeper will sound 3 seconds before the operator star ts.
LRA Linear Residential Actuator Installation Guide - 13 - 228158 Revision X13 2-3-2009 Advanced Controller Progr amming Entering Advanced Progr amming Mode T o access and program the Advanced Programming functions, f or each programming session, Adv anced Programming must be enab led.
LRA Linear Residential Actuator Installation Guide - 14 - 228158 Revision X13 2-3-2009 Advanced Controller Progr amming (Cont.) Auxiliary Relay Mode The Auxiliary Relay has nor mally open and nor mally closed contacts. The f actor y setting disables the A uxiliar y Relay .
LRA Linear Residential Actuator Installation Guide - 15 - 228158 Revision X13 2-3-2009 Advanced Controller Progr amming (Cont.) Soft Start/Stop Duration This function causes the operator to star t and stop the DC motor slowly reducing gate wear and tear (at the full open or closed positions only).
LRA Linear Residential Actuator Installation Guide - 16 - 228158 Revision X13 2-3-2009 Advanced Controller Progr amming (Cont.) Radio Enable The Controller contains a built-in MegaCode ® radio receiver to allow activation from up to 40 access control transmitters and two Model MGT (gate edge) transmitters.
LRA Linear Residential Actuator Installation Guide - 17 - 228158 Revision X13 2-3-2009 Loop Lay out Illustration 2" 3/8" 4 FT. MINIMU M USE RELIEF CUT S AT CORNER S TWIST WIRE FROM END OF LOOPS BACK TO OPERATOR AT LEAST SIX TIMES PE R FOOT 2" MAX.
LRA Linear Residential Actuator Installation Guide - 18 - 228158 Revision X13 2-3-2009 Safety Edge Lay out Illustration RECEIVER FOR GATE EDGE TRANS MITTER BUILT INTO CONTROLLER GATE EDGE TRANSMITTER #1 SEPARATE PEDESTRIAN GATE REQUIRED 7FT.
LRA Linear Residential Actuator Installation Guide - 19 - 228158 Revision X13 2-3-2009 Photoey e Installation Illustration SEPARATE PEDESTRIAN GATE REQ UIRED 7 FT.
LRA Linear Residential Actuator Installation Guide - 20 - 228158 Revision X13 2-3-2009 Dual Gate Installations T wo oper ato rs can be used in du al gat e inst all ati ons . T he ope ra tor s communicate with each other through the 3-wire COMM LINK terminals.
LRA Linear Residential Actuator Installation Guide - 21 - 228158 Revision X13 2-3-2009 Operation Indications During nor mal oper ation, the Controller’ s displa ys will indicate current operating conditions and status .
LRA Linear Residential Actuator Installation Guide - 22 - 228158 Revision X13 2-3-2009 T roubleshooting Contacting T echnical Support F or technical questions regarding Linear gate operators, contact the T echnical Ser vices Depar tment at: 1-800-421-1587 from 6:30 AM to 4:30 PM P acific time Operator fails to start A.
LRA Linear Residential Actuator Installation Guide - 23 - 228158 Revision X13 2-3-2009 Model LRA Replacement P arts HARDWARE KI T POST BRACKET KI T GATE BRACKE T KI LIMIT SWITCH KIT T WORM DRIVE CA P .
LRA Linear Residential Actuator Installation Guide - 24 - 228158 Revision X13 2-3-2009 Prev entative Maintenance General Linear gate operators are designed for many y ears of trouble-free operation and, under recommended operating conditions, will require only minimal maintenance.
LRA Linear Residential Actuator Installation Guide - 25 - 228158 Revision X13 2-3-2009.
LRA Linear Residential Actuator Installation Guide - 26 - 228158 Revision X13 2-3-2009 Gate Operator Installation Checklist ❑ ❑ 1. The gate has been chec ked to make sure it is le vel and mov es freely in both directions.
An important point after buying a device Linear LRA (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Linear LRA yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Linear LRA - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Linear LRA you will learn all the available features of the product, as well as information on its operation. The information that you get Linear LRA will certainly help you make a decision on the purchase.
If you already are a holder of Linear LRA, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Linear LRA.
However, one of the most important roles played by the user manual is to help in solving problems with Linear LRA. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Linear LRA along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center