Black 0001 Black 0001 SUPER VISED WIRELESS SECURIT Y CONSOLE Installation & P rogramming Instructions (760) 438-7000 • FAX (760) 438-7043 USA & Canada (800) 421-1587 & (800) 392-0123 Tol.
Black 0002 Black 0002 INTRODUC TION CONGRATULATIONS for selecting Linear’s DVS-1200 Secur ity System. The DVS-1200 Console incorporates many advanced and sophisticated features. The system can be expanded and customized to fit the installation’s specific needs.
Black 0003 Black 0003 T ABLE OF CONTENT S 1. THE DVS-1200 SEC URITY SYSTEM . . . . . . . . . . . . . . . . . . . . . . . . . . 2 CONSOLE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 DOOR/WIN DOW SENSOR S . . . . . . .
Black 0004 Black 0004 1 . THE DVS-1 200 SECURIT Y S Y S TEM CONSOLE The DVS-1200 Console is the heart of the system. It monitors all of the system’s wireless sensors and controls the alarm sirens. The Console cons tantly monitors the condition of the system’s sensors, displaying which protected doors and windows are open or closed.
Black 0005 Black 0005 DOOR/WINDOW SENSORS The DXS-31 sensors monitor doors and windows. They se nd radio signals to the Console. One type of signal is sent when the door or window is opened, and a different type of signal is sent when the do or or window is closed .
Black 0006 Black 0006 2. SECURIT Y S Y S TEM FL OOR PL AN EXAMPLE SYST EM ◆ The example shows a typical DVS-1200 system. ◆ Any or all of the accessories shown can b e used. ◆ A total of 12 sensors (includ ing keypads) can be used with each Console.
Black 0007 Black 0007 3. T YPICAL S Y S TEM SENSORS DOOR/WINDOW SENSOR ◆ Sensor mounts on door o r window with adjacent magnet. ◆ Opening door or windo w moves magnet away, triggering sensor. ◆ Pressing the case causes sensor to send a test signal.
Black 0008 Black 0008 4. CONSOLE FE A TURES 1 24-HOUR BUTTONS ★ Pressing the [ FIRE ] button f or two seconds sound s the fire sire n and sends a “fire” m essage to a centra l monitoring st ation through t he digital communicator (if the system is monitored ).
Black 0009 Black 0009 10 AUXILIARY FUSE ★ Type 2AG, 1-amp f use. ★ Protec ts the external relay outpu t when used with we t contacts (12 VD C switche d ou t). ★ Fuse will blow when loa d exceeds 1 a mp. ✍ WARNING: For continued protection against the risk of fire, replace only with the s ame type and rating of fuse.
Black 0010 Black 0010 5. CONSOLE INS T ALL A TION CONSOLE LOCATIO N ✍ NOTE: Sensor signals m ust be able to re ach the Console. ✔ Try to centrally locate the Console. ✔ Keep Console away fro m large metal appliances. ✔ Maximum recommended sensor range is 400 feet (system tested at 1000 feet).
Black 0011 Black 0011 EXTERNAL CONSOLE SPEAKER CO NNECTION (OPTIONAL) ◆ An external console speaker sound s system tones and alerts occupants with a loud siren during alar m. ◆ With the VB-2 module installed, the Cen tral Station can talk to the o ccupants through the external console speaker.
Black 0012 Black 0012 TELEPHONE LINE CO NNECTION (OPTIONAL) ◆ Connect the Console to the telephone line if the system is monitored, requires 2-way audio, or requires telephone remo te command. ◆ Telephone ring & tip terminals are for connection to th e incoming telephon e line.
Black 0013 Black 0013 CONSOLE POWER CONNECTION ◆ The Console is powered by a low voltage plug-in transformer. ◆ Use up to 25 feet of 20 AWG or larger two-conductor wire to con nect the transformer to the Console. Route the power wires from the plug-in transformer to the Console.
Black 0014 Black 0014 6. BASIC CONSOLE PROGRAMMING ◆ In a new installation, when power is first applied, the Console’s master user code is “1234”. CHANGE TH E MASTER USER CODE ✍ NO TE : Local programming must be entered on the Console’s keypad, not on a wirel ess remote keypad.
Black 0015 Black 0015 PROGRAMMING DIFFERENT SENSOR TYPES ◆ Follow the instructions on the previous page to select a sensor number to prog ram the sensor into. ✍ NOTE: A sensor can be programmed into more than one location. Be sure to choose an unused sensor numb er.
Black 0016 Black 0016 7 . BASIC SENSOR INS T ALL A TION ◆ Each accessory sensor is packaged with its own set of installation instructions specific to the model of sensor. ◆ Refer to the sensor’s instructions for details on installing, operating, and testin g of the sensor.
Black 0017 Black 0017 DXS-31 DOOR/WINDOW SENSORS ◆ The DXS-31 sensors can be used to mo nitor doors, windows, cabinets, crawl space do ors, gates, freezer doors, and many oth er moving objects that co uld be used for intru sion or need to be monitored.
Black 0018 Black 0018 8. CUS T OMIZING THE CONSOLE ◆ The Console can be customized for the specific installation. ◆ A label sheet with sensor location n ames is provided with the Conso le.
Black 0019 Black 0019 9. CONSOLE OPERA TING MODES OFF MODE ◆ Use this mode to disarm the burglary portion of the system. ◆ Switching to Off Mode sto p s any alarms in progress. ◆ The 24-hour functions are still active in Off Mode and can be triggered b y pressing the [ FIRE ] or [ EMERGENCY ] button.
Black 0020 Black 0020 HOME MODE ◆ Use this mode when sleeping or when an yone is staying inside. ◆ Home Mode causes an instant alarm wh en any perimeter sensor is triggered. ◆ Home Mode causes a delayed alarm when any exit/entry sensor is triggered (except in Home Instant Mode when they are instan t).
Black 0021 Black 0021 AWAY MODE ◆ Use this mode when no one will be staying home. ◆ Each burglary sensor can trigger the siren once per arming period. ◆ Away Mode causes an instan t alarm when any perimeter sensor is tri ggered. ◆ Away Mode causes a delayed alarm when any exit/entry sensor is triggered.
Black 0022 Black 0022 TEST MODE ◆ Even though this is a self-monitor ing supervised system, the National Burglar and Fire Alarm Association recommends that all security systems should be tested manually on a regular basis. ◆ The Console must be in Off Mode before go ing to Test Mode.
Black 0023 Black 0023 1 0. S Y S TEM TR OUBLE INDICA TIONS ◆ The DVS-1200 Console is a s elf-monitoring supervised wirele ss system. ◆ If the Console detect s a problem with any of the supervised .
Black 0024 Black 0024 1 1 . CUS T OMIZING THE S Y S TEM ◆ Adding additional sen sors will increase the protection provid ed by the system. ◆ All ground-level perimeter openings an d accessible upper-story openings need protection. ◆ Motion detectors can protect interior areas and areas where valuables are kept.
Black 0025 Black 0025 MAKING A SENSOR A 24-HOU R DOOR CHIME ◆ Sensors can be programmed to cause th e Console to chime an y time they’re activated.
Black 0026 Black 0026 MAKING A SENSOR ACTIVATE A DIFFER ENT ZONE ◆ Any sensor can be reprogrammed to activate any of the Console’s zon es. ◆ The sensor must have already been learned by the Console (see “Adding sen sors to the System” for d etails).
Black 0027 Black 0027 1 2. ADV ANCED PROGRAMMING ◆ To perform any of the advanced prog ramming steps, the Console must be in the Setup Mode. ◆ Each programming function is performed with similar keystrokes.
Black 0028 Black 0028 CHANGING A SENSORS SUPERVISION ◆ When a sensor is programmed, the Con sole automatically recognizes it as supervised o r non-supervised. ◆ The Console ex pects hourly status transmiss ions from any sensor programmed as supervised.
Black 0029 Black 0029 FIRE SIREN TIME ◆ The factory-set fire siren time is five minutes (UL installation maximum). ◆ The fire siren time can be adjusted from on e to 30 minutes. AUTOMATION OUTPUT TIME ◆ The factory setting causes the Automatio n Output to toggle between on and off with each activation.
Black 0030 Black 0030 SILENT BURGLARY ALARMS ◆ The factory setting causes audible burglary alarms. ◆ Alternately, the Console can be programmed for silent burglary alarms. SILENT EMERGENCY ALARMS ◆ The factory setting causes audible emergency alarms.
Black 0031 Black 0031 AUTOMATION OUTPUT MODE DURING ALARM ✍ NOTE: For the Automation Ou tput to acti vate during an alarm, t hat function must be enabled with Programming Step 71 or 72. ◆ If the Automation output is programmed to activate during an alarm, it can be programmed to flash or b e steady.
Black 0032 Black 0032 AUTOMATION OUTPUT WHILE ARMED ◆ The factory setting causes the Console’s Automation Output to activate when pressing the [ (A) ] key, or when it’s triggered with a two-button remote control. ◆ In addition, the Console can b e programmed to activate the Automation Output when the system is armed.
Black 0033 Black 0033 ADDITIONAL USER CODES ◆ The Console can be programmed with five restricted user codes and one page ale rt user code. ◆ The additional codes operate the system as usual, but cannot access Setup Mode.
Black 0034 Black 0034 1 3. COMMUNICA T OR PROGRAMMING SETUP MODE ◆ To perform any of the commun icator programming steps, the Conso le must be in the Setup Mode.
Black 0035 Black 0035 GENERAL COMMUNICATOR OPTIONS COMMUNICATOR ENABLE ◆ The factory setting for the Console disables the communicator. If th e system is going to be a non-monitored, local alarm only, leave the communicator disabled.
Black 0036 Black 0036 CALL LIMITER ◆ The factory setting for the c all limiter is OFF. This allows the co mmunicator to report burglary alarms, once for each sensor, as many times as they are triggered. ◆ Optionally, the Console can be prog rammed to only allow five burglary reports to tal per arming pe riod.
Black 0037 Black 0037 COMMUNICATOR REPORTING OPTIONS REPORTING FORMAT ◆ The factory setting causes the commu nicator to report using th e 4 by 2 format. This format allows four-digit accoun t numbers from 0000 to 9999 and provides two -digit alarm codes.
Black 0038 Black 0038 ACCOUNT NUMBER ◆ The communicator’s account numb er entered must be 4-digits lon g. ◆ The factory setting for th e account number is 0000. ◆ Enter an account n umber from 0000 to 9999. PRIMARY TELEPHONE NUMBER ◆ The primary Central Sta tion telephone number can be up to 20-digits lo ng.
Black 0039 Black 0039 REPORT CONSOLE TROU BLE ◆ The factory setting does not report Co nsole trouble events to the Central Station . ◆ Alternately, the communicator can be programmed to report Console trouble even ts. These include all con ditions that light th e Console’s BATTERIES or TROUBLE indicator.
Black 0040 Black 0040 COMMUNICATOR REPORTING CODES ◆ The two-digit communicator reportin g code for each event has a factory set value. These values may be customized to fit the specific installation and the reporting requirements of the Central Station monitoring the system.
Black 0041 Black 0041 FORCE ARMING REPORTING CODE ◆ Programming S tep #258 ◆ The factory set reporting code for force arming is “65” (Code 574 with Ad emco). ◆ Any value from 0-99 can be programmed for this event (0 = no report). ✍ NOTE: For force arming reporting, force arming reports must be enabled.
Black 0042 Black 0042 4 BY 2 FORMAT POINT ID REPORTING CODES 4 BY 2 FORMAT POINT ID ALARM REPORT CODES ◆ Refer to the 4 by 2 Format Point ID Repo rting Code table to view/edit the alarm reporting codes for each of the 12 sensors. The communicator will send these cod es if Point ID is enabled and any senso r triggers an alarm.
Black 0043 Black 0043 POINT ID RE PORTING COD ES STEP # PROGRA MMING FUNCTION POSSIBLE VALUES FACTORY VALUE INSTALLATIO N VALUE 210 SENSOR 1 ALARM REPO RT CODE 0 - 99 11 211 SENSOR 2 ALARM REPO RT COD.
Black 0044 Black 0044 IMPOR T ANT INFORMA TION LINEAR LIMITED WARRANTY This Linear product is warranted against defects in material and workmanship for twelve (12) months.
An important point after buying a device Linear DVS-1200 (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Linear DVS-1200 yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Linear DVS-1200 - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Linear DVS-1200 you will learn all the available features of the product, as well as information on its operation. The information that you get Linear DVS-1200 will certainly help you make a decision on the purchase.
If you already are a holder of Linear DVS-1200, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Linear DVS-1200.
However, one of the most important roles played by the user manual is to help in solving problems with Linear DVS-1200. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Linear DVS-1200 along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center