Instruction/ maintenance manual of the product L30 BF-2 Lenoxx Electronics
Go to page of 25
INSTALLATION AND OPERATION MANUAL FREESTANDING VENTED GAS FIREPLACE HEATER MODELS L30 BF-2 (B-Vent) WARNING If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, person injury or loss of life.
IMPORTANT WARNINGS / CAUTIONS CAUTION: Read this manual thoroughly before s tarting installation. For your safety, follow the installation, op- eration and maintenance inst ructions exactly without dev iation. Failure to follow these instructions may result in a possible fire hazard and may void the warranty.
TABLE OF CONTENTS PAGE 3 Important W arnings ................................................ 2 Testing / L isting, Using t his Manual ........................ 3 Planning Your Installati on ..................................... 4-6 Installat ion .....
PLANNING YOUR INSTALLATION PAGE 4 LOCAL AND NATIONAL CODE REQUI REMENTS The ins tallation of these applianc es mus t conform with local c odes or, in the absence of local cod es, with the National F uel Gas Code , (for USA) NF PA 54 / ANSI Z223.1-lat est edition.
PLANNING YOUR INSTALLATION PAGE 5 QUESTIONS T O ASK THE LOCAL BUILDING OFFI- CIAL Correct insta llati on is c ritic al a nd im perative f or r educ ing fire hazar ds and per ilous con ditions that c an ar ise when gas appl iances f uncti on im pr operly.
PLANNING YOUR INSTALLATION PAGE 6 CLEARANCES T O COMBUSTIBLE M ATERIALS Thes e applia nces can be inst alled in m ost res identia l room config urations , parallel to a re ar or adjacen t wall, or i n an alcov e that al lows f or the m inim um c learanc es to c om bus - tible surf aces.
INSTALLA TION See Pipe M anufact urers clearan ces for Pipe Cl earances Venting Requirements EXAMPL ES OF VENT ING INSTALL A T ION APPLIC ATIONS PAGE 7 Model: L30 BF-2 (B-Ve nt) Ve nting Requirements A pproved for vertical termination only.
INSTALLA TION PAGE 8 GAS SU PP LY HOOKUP If using pipe other than black iron pipe see NFPA 54-National Fire Protection Association / ANSI Z223.1-Amer ican National Standards Institute; and local code for specific requirements for the type of p ipe used.
INSTALLA TION PAGE 9 DOOR OPERA TION After setup of the logs and em ber s is c om plete, the g lass door mus t be closed. T he glass door is m ounted on hinges at the left sid e of the firebox and is s ecured i n the closed posit ion by two draw latches mounted o n the right side of the firebox.
INSTALLA TION PAGE 10 GAS APP LIANCE FINA L ASSE MBLY After the appli ance has been proper ly insta lled and all gas conn ections have been made an d tested, you can now insta ll the log set. See Door Ass embly on pa ge 11 for door removal i nstructio ns.
INSTALLA TION PAGE 11 INST A L LATION CH ECK LIST Read and under stand thes e instructio ns before using applianc e. Go thro ugh this insta llation chec klist: G Ensure that the lo g set is prop erl y installed . Use c au- tion when hand li ng the logs .
CARE A N D OPERA TION PAGE 12 FOR YOUR S A FET Y READ BEFORE LIGHTING WARNING: If you do not fo llow these instruc- tions exactly, a fire or explosion ma y result causing pr operty damage, personal injury or loss of life. A. This appliance has a pi lot which m ust be lit.
CARE A N D OPERA TION PAGE 13 “BRE AK-IN” PERIOD The f inish on this appliance is a h igh tem perature pai nt that requir es time and t emperatur e to complet ely cure. The curing proces s will take 2 or 3 bur ns (heat up and cool do wn periods). W e rec o mmend that you ventil ate the house during t he initial burns .
PROPAN E CONVERSION PAGE 14 PROP A N E CONVERS ION PROCEDU RE (Only required if Pr opane gas is used) This appliance is d esigned t o o perate on na tural gas , or propane (L P). It is f actory set f or use with natur al gas and requir es field con v ersion for use with pr opane.
PROPAN E CONVERSION PAGE 15 7. High / Lo w Pres sure Regulator I nstallation Proce- dure: a. Remove regulat or cap and conv ersion scre w (see follo wing il lus tr at ion). b. Install th e new con version screw (R ed = Propan e LP gas, B lue = Natural G as).
MAINTEN A NCE A lw ay s Turn Off Gas Control Valve Before Cleaning . A nnual Maintenance Should Only Be Performed By A Qualified Service Technicia n: PAGE 16 LOG SET Remo ving & Cleaning Logs - Caref ully rem ove the logs (rem oving top logs, then lifting f ront log out, the n rear log).
MAINTEN A NCE A lw ay s Turn Off Gas Control Valve Before Cleaning . A nnual Maintenance Should Only Be Performed By A Qualified Service Technicia n: PAGE 17 PERIODIC CH ECK OF PILOT AND BURNER FLA MES Check the operati on of the pilo t and cycle t he burner.
WIRING DI A GR A MS PAGE 18 GAS CONTROL A ND SAFETY SYST EM WIRING DI A GR A M CAUTIO N: Label all wiring pr ior to disconnec tion when s ervicing contr ols. W iring errors can caus e impr oper and dan- gerous o peration. Verify proper operation af ter servic ing.
TROUBLESHOOTING Qualif ied Techni cians Only PAGE 19 PROBLEM CAUSE(S) SOLUTIONS 1) Pilot will not light, and Pie z o Igniter does not produce a heavy blue spark. a. Electrode wire (at Pie z o Igniter) not pushed completely on. b. Piezo i gniter is defective • Make sure connections are solid.
REPLA CEMENT PART S Model L30- 2 BF PAGE 20 Item # Descriptio n Catalog # 1 Trim, Deco rative 52L04 2 Window Fram e, Charcoal 17M63 3 Burner Assem bl y 17M61 4 Blower, Air Circ ula tin g 52L19 5 Power.
OPTIONA L A CCESSORIES PAGE 21 Item # Descriptio n Catalog # Model 1 Door Kit, L30 BF-2, Gol d 14M09 DK3 B-G 2 Brick aded Interior Ki t, L30 14M06 BRK- L30 3 Deluxe Rem ote Control ( Therm ostaticall .
SPECIFICA TIONS: Model L30 BF- 2 PAGE 22 Approx. Sq. Ft. Heating Cap acity ∼ ∼ ∼ ∼ 1500 sq. ft. Flue Size 4” - Top Vent Height Ov erall 29” Height to Flue Outlet 30 3/8” Width 29 7/8” Depth 16 1/8” Fuel Natural Gas (standard) (or) LP Gas (c onvertible).
SAFETY / LISTING LA BEL: Model L30 BF-2 PAGE 23.
PAGE 24 OWNERSHIP R ECORDS Dealer’s Nam e: Dealer’s A ddress: City: State: Zip Code: Serial N umber: Date of Purchase: Date Instal led: Notes: SERVIC E AND M A INT ENANCE LOG Servi ce Servi ce Ser.
1110 West Taft Av e n ue Orange, CA 92865.
An important point after buying a device Lenoxx Electronics L30 BF-2 (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Lenoxx Electronics L30 BF-2 yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Lenoxx Electronics L30 BF-2 - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Lenoxx Electronics L30 BF-2 you will learn all the available features of the product, as well as information on its operation. The information that you get Lenoxx Electronics L30 BF-2 will certainly help you make a decision on the purchase.
If you already are a holder of Lenoxx Electronics L30 BF-2, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Lenoxx Electronics L30 BF-2.
However, one of the most important roles played by the user manual is to help in solving problems with Lenoxx Electronics L30 BF-2. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Lenoxx Electronics L30 BF-2 along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center