Report No. 050-S-15c-5 INST ALLA TION AND OPERA TION MANUAL Direct-V ent Gas Fireplace Inserts Retain These Instructions For Future Reference W ARNINGS • Hot! Do not touch! The glass and surfaces of this appliance will be hot during operation and will retain heat for a while after shutting off the appliance.
2 C autions & s afety FOR YOUR SAFETY do not install or operate your Ravenna™ gas insert without first reading & under - standing this manual. Any installation or operation of the appliance deviating from that which is stated in this manual WILL void the warranty & may be hazardous.
3 T able of Contents C autions & s afety ..................................................................................... 2 o rifiCe s ize / a l titude a djustment .................................................................... 4 f ireplaCe r equirements .
4 Orifice Size/Altitude Adjustment For altitudes above 2,000 feet (In Canada 4,500 FT/1370 M),the orifice should be de-rated by 4% for ever y 1,000 feet to maintain the proper ratio of gas to air . Improper orifice sizing may result in damage and unsafe conditions.
5 Inspection The state or local gas inspector of the side wall horizontally vented gas fuel ed equi pme nt shal l not app rove the insta lla tion unless, upon ins pect ion, the inspector obser ves carbon monoxide detectors and signage installed in accordance with the provisions of 248 CMR 5.
6 Pre-Installation f ea tures Installation Options Manufactured (Mobile) Home Natural Gas Or Propane (LP) Bedrooms Optional Wall-mounted Or Remote Thermostat Electrical The standard fan motor requires 120 Volts AC for operation. The fireplace is not dependent on the fan or an outside elec - trical supply to operate.
7 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. i nsert d imensions m inimum f ireplaCe o pening r equired A = 29-3/4” (756mm) Front Opening B = 19-1/2” (495mm) Height C = 19” (483mm) Rear Width D = 16” (406mm) Fireplace Depth * T op air duct will need to be removed for short ZC applica - tions.
8 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. Note: Hearth protection to be min. 3/8” (10mm) thick non- combustible or equivalent, with a k factor of .84. i nsert l eveling At each front and rear corner of the insert is an adjustable leg provided to level the insert should the hearth of the fireplace be uneven.
9 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. v ertiCal v enting The vent pipes must be connected to the proper collars on the unit and the exhaust vent pipe must be connected to the termination cap or the unit will not operate. The combustion air vent pipe can be connected to the termination cap or it can terminate inside the chimney .
10 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. z ero C learanCe f ireplaCe i nst allation This insert may be installed in a masonr y or factor y built/zero clearance (ZC) fireplace. When installing in a ZC fireplace, the ZC grate must be removed and the ZC damper must be removed or secured open.
11 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. 4. Install a light layer of rockwool directly over the ports. - A light layer will give a more constant rear flame. - A heavy layer will give more glow , but will need to be adjusted after light up.
12 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. Gas Line Installation After leveling, position the insert in the fireplace - holding it about six inches out from its final location. Caution: Specific hearth requirements apply (see Clear - ances to Combustibles).
13 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. Operating Instructions p re -l ighting C heCklist Be sure to check these items before the initial lighting of the insert: c The insert gas label corresponds to the gas supply avail- able - that is "natural gas" for natural gas or "LP gas" for LP gas.
14 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. W ARNINGS • Improper installation, adjustment, alteration, service or maintenance can cause injur y or property damage. For assistance or additional infor mati on, consult a qualifi ed installer , service agency or your gas supplier .
15 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. Flame Color & Behavior Y our Ravenna™ gas insert is designed for maximum heat- ing efficiency . Therefore, upon lighting of the main burner the flames will be semi-transparent or “bluish.
16 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. o pera ting o ptions The rocker switch on your Ravenna™ gas insert is used to turn the burner on and off while the pilot is on. The rocker switch can be installed in the hole in the right side of the top surround panel or in the hole in the panel to the left of the igniter button.
17 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. Maintenance & Ser vicing m aintenanCe C heCklist The following should only be performed by a qualified service technician. Caution: Label all wires prior to disconnection when servicing controls.
18 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. Fan Snap Switch Fan Speed Control White Ground (Green) Black Blower Black (Hot) White (Neutral) Power Source Blower Wiring Schematic g lass d oor r emov al Caution: Do not slam or strike glass door or damage may occur .
19 SYMPTOM PROBABLE CAUSE CORRECTIVE ACTION Thin black coating (soot) forms on the viewing glass, logs, or firebox Improper log or ember placement Improper air shutter setting Not enough combus- tion air See Brick Panel and Log Set Installation on Pages 10 & 11 .
20 Replacement Parts Ravenna™ 33/40 (RDV33/40) Part Number Description H3132 Cassette Assembly NG 33,000 BTU (if LP , also requires H5433 Conversion Kit) H3045 Cassette Assembly NG 40,000 BTU (if LP.
21 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. Fi nis h P ane l s / fr ont Su ppo rts Ca t. No. De scr ipt ion 75 2 5 2 "Z C L o w er F in i s h P a ne l /B ay F ac e Su p p or t *R e q.
22 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. MINIMUM CLEARANCES TO COMBUSTIBLES RDV40 RDV33 E = T op Facing to Bottom of Insert 35.5”(902mm) 31.5”(800mm) F = Cent er of G las s to Si de F aci ng o r S id e W al l 25.5”(648mm) 25.5” (648mm) *J = 10.
23 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. CAUT ION : YOU R CO UNT R Y G AS APPLIA NCE MUS T AL WA YS B E O PER A TE D W ITH GLA SS DOO R IN PL ACE . STO P! Rea d t he s afe ty info rma tio n a bove be for e pr oce edi ng. 1. Ope n t he l owe r d oor .
Printed in U.S.A. © Lennox Hearth Products 2007 P/N 775,218M REV . B 12/2007 Lennox™ reserves the right to make changes at any time, without notice, in design, materials, specifications, prices and also to discontinue colors, styles and products. Consult your local distributor for fireplace code information.
An important point after buying a device Lennox RAVENNA RDV33\40 (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Lennox RAVENNA RDV33\40 yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Lennox RAVENNA RDV33\40 - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Lennox RAVENNA RDV33\40 you will learn all the available features of the product, as well as information on its operation. The information that you get Lennox RAVENNA RDV33\40 will certainly help you make a decision on the purchase.
If you already are a holder of Lennox RAVENNA RDV33\40, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Lennox RAVENNA RDV33\40.
However, one of the most important roles played by the user manual is to help in solving problems with Lennox RAVENNA RDV33\40. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Lennox RAVENNA RDV33\40 along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center