Instruction/ maintenance manual of the product Direct-Vent Gas Lennox Hearth Products
Go to page of 24
Report No. 050-S-18b-5 INST ALLA TION AND OPERA TION MANUAL W ARNINGS • Hot! Do not touch! The glass and surfaces of this appliance will be hot during operation and will retain heat for a while after shutting off the appliance. Severe burns may result.
2 T able of Contents C autions & s afety ..................................................................................... 3 o rifiCe s ize / a l titude a djustment .................................................................... 4 f ireplaCe r equirements .
3 C autions & s afety FOR YOUR SAFETY do not install or operate your Medina™ gas insert without first reading & understand- ing this manual. Any installation or operation of the appliance deviating from that which is stated in this manual WILL void the warranty & may be hazardous.
4 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. Orifice Size/Altitude Adjustment For altitudes above 2,000 feet (In Canada 4,500 FT/1370 M),the orifice should be de-rated by 4% for every 1,000 feet to maintain the proper ratio of gas to air .
5 Inspection The state or local gas inspector of the side wall horizontally vented gas fuel ed equi pme nt shal l not app rove the insta lla tion unless, upon ins pect ion, the inspector obser ves carbon monoxide detectors and signage installed in accordance with the provisions of 248 CMR 5.
6 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. Pre-Installation f ea tures Installation Options Residential - Vented V ertical Only Manufactured (Mobile) Home Natural Gas Or Propane (LP) Bedrooms Optional Wall-mounted Or Remote Thermostat Electrical The fan motor requires 120 Volts AC for operation.
7 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. i nsert d imensions m inimum f ireplaCe o pening r equired A = 29-3/4” (756mm) Front Opening B = 17-1/4” (438mm) Height C = 19” (483mm) Rear Width D = 16” (406mm) Fireplace Depth * T op air duct will need to be removed for short ZC applica - tions.
8 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. Facing & Mantel - Side View f aCing and m antel C learanCes Note: Hearth protection to be min.
9 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. v ertiCal v enting The vent pipes must be connected to the proper collars on the unit and the exhaust vent pipe must be connected to the termination cap or the unit will not operate. The combustion air vent pipe can be connected to the termination cap or it can terminate inside the chimney .
10 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. z ero C learanCe f ireplaCe i nst allation This insert may be installed in a masonr y or factor y built/zero clearance (ZC) fireplace. When installing in a ZC fireplace, the ZC grate must be removed and the ZC damper must be removed or secured open.
11 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. T op Log Ports Install front logs on retainer slots. Place top log on pin. Figure 10 Figure 11 s urround p anels i nst allation The Medina insert surround panels is made of heavy gage steel for durability and, if desired, for the ease of making an inside fit in the fireplace.
12 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. Gas Line Installation After leveling, position the insert in the fireplace - holding it about six inches out from its final location. Caution: Specific hearth requirements apply (see Clear - ances to Combustibles).
13 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. Operating Instructions p re -l ighting C heCklist Be sure to check these items before the initial lighting of the insert: c The insert gas label corresponds to the gas supply avail- able - that is "natural gas" for natural gas or "LP gas" for LP gas.
14 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. 5. Locate the pilot by looking over the top of the left front log. A blue flame will be seen when the pilot is lit. 6. T urn the gas control knob counter -clockwise to the "PILOT" position.
15 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. Paint Curing This insert has been painted with StoveBright high tem- perature metallic stove paint.
16 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. Millivolt Control Schematic Sparker Pilot Hood ON/OFF Rocker Switch, Thermostat, or Remote Thermostat Pilot Assembly Thermocouple Piezo Igniter.
17 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. Maintenance & Ser vicing m aintenanCe C heCklist The following should only be performed by a qualified service technician. Caution: Label all wires prior to disconnection when servicing controls.
18 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. Fan Snap Switch Fan Speed Control White Ground (Green) Black Blower Black (Hot) White (Neutral) Power Source Blower Wiring Schematic g lass d oor r emov al Caution: Do not slam or strike glass door or damage may occur .
19 SYMPTOM PROBABLE CAUSE CORRECTIVE ACTION Thin black coating (soot) forms on the viewing glass, logs, or firebox Improper log or ember placement Improper air shutter setting Not enough combus- tion air See Log Set Installation on Page 10 . If there is soot in one specific location, the rockwool below this location needs to be adjusted.
20 Replacement Parts Medina™ (MED) Part Number Description H6033 Cassette Assembly , NG (if LP , also requires H5464 conversion kit) H3070 Main Burner Assembly H5922 Pilot Assembly , Convertible NG .
21 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. MINIMUM CLEARANCES TO COMBUSTIBLES E = 31.5 ” ( 80 0m m) fr om T op F ac in g to Bo tt om of I nse rt F = 25.5 ” ( 64 8m m) fr om Ce nt er of G la ss to S ide F ac ing o r Sid e W al l *J = 39” (99 1m m) fr om 1 0.
22 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. CAUT ION : YOUR CO UNT RY G AS AP PLI ANC E MU ST ALW A YS BE O PER A TE D W ITH GLA SS DOO R IN PL ACE . STO P! Rea d th e s afe ty i nfo rma tion ab ove bef ore pr ocee din g. 1. Open the low er door .
23 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. Y our Fireplace Insert's Model Number ___________________________________ Y our Fireplace Insert’ s Serial Number ______________________.
Printed in U.S.A. © Lennox Hearth Products 2007 P/N 775,221M REV . A 05/2007 Lennox™ reserves the right to make changes at any time, without notice, in design, materials, specifications, prices and also to discontinue colors, styles and products. Consult your local distributor for fireplace code information.
An important point after buying a device Lennox Hearth Products Direct-Vent Gas (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Lennox Hearth Products Direct-Vent Gas yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Lennox Hearth Products Direct-Vent Gas - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Lennox Hearth Products Direct-Vent Gas you will learn all the available features of the product, as well as information on its operation. The information that you get Lennox Hearth Products Direct-Vent Gas will certainly help you make a decision on the purchase.
If you already are a holder of Lennox Hearth Products Direct-Vent Gas, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Lennox Hearth Products Direct-Vent Gas.
However, one of the most important roles played by the user manual is to help in solving problems with Lennox Hearth Products Direct-Vent Gas. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Lennox Hearth Products Direct-Vent Gas along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center