Instruction/ maintenance manual of the product LMBV-42REN Lennox Hearth
Go to page of 16
1 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. INST ALLA TION INSTRUCTIONS 42" B-VENTED GAS APPLIANCES P/N 850,041M REV. A 02/2007 Millivolt Models Electronic Models LMBV-42RMN LMBV -42REN LMBV-42RMP FOR YOUR SAFETY: Do not store or use gasoline or other flammable vapors or liquids in the vicin- ity of this or any other appliance.
2 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. TABLE OF CONTENTS Introduction ..................................... page 2 General Information ......................... page 2 Massachusetts and New York Requirements ...............................
3 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. Carbon Monoxide Poisoning: Early signs of carbon monoxide poisoning are similar to the flu with headaches, dizziness and/or nausea.
4 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. CLEARANCES Minimum clearance to combustibles for the ap- pliance is as follows: sides and back - 0" (0 mm), floor - 0" (0 mm), adjacent wall - 0" (0 mm), ceiling - 64" (1625 mm). Venting Gas Vent Rule – Gas vent caps are not permit- ted within 8 feet (2.
5 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. FRAMING SPECIFICATIONS Figure 4 Figure 5 Figure 6 Framing Dimensions Note: All framing dimensions calculated for 1/2" dry wall at the appliance face. If sheathing the chase or finishing with other thickness materials, calculations will need to be made.
6 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. All appliances are equipped with a gas flex line and shutoff valve attached directly to the gas control valve.
7 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. Figure 11 Step 5. Field Wiring – Refer to Section A for millivolt appliances and Section B for electronic appliances. A. Millivolt Wiring – The gas valve has been set in place and has been pre-wired at the factory.
8 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. Figure 14 Note: Supply wires may be alternatively connected to the outlet using the screw terminals, however the black supply wire must be wired to a terminal that is opposite (across the outlet) the point where the white supply wire is connected.
9 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. Replace logs if removed for pilot inspection. To light the burner; turn “ON” the remote wall switch and rotate the gas valve control knob counterclockwise to the “ON” position (“ON” will be to the left hand side of the valve).
10 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. When satisfied that the appliance operates properly, proceed to finish the installation. Leave the control knob/lever in “ON” position and turn the remote switch “OFF.” Replace the refractory access panel.
11 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. Fireplace Opening Spacer Finished Wall Header 1 2 3 4 5 6 7 8 9 10 11 12 9 10 11 12 Combustible Mantel Clearances Inches Min. Height of Mantel Above Fireplace Opening Max.Length of Mantels Three mantels are shown (dark gray elongated rectangles)- one, 1 ¹⁄₂ in.
12 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. Gas Conversion Kits In Canada THE CONVERSION SHALL BE CARRIED OUT IN ACCORDANCE WITH THE REQUIREMENTS OF THE PROVINCIAL AUTHORITIES HAVING JURISDICTION AND IN ACCORDANCE WITH THE REQUIREMENTS OF THE CAN1-B149.
13 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. Step 5. Attach manometer to the manifold side pressure test fitting and verify manifold pressure reads 3.5 inches water column (0.87 kPa) for natural gas, and 10.0 inches water column (2.49 kPa) for propane gas.
14 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. NOTE: THIS PAGE INTENTIONALLY LEFT BLANK..
15 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. NOTE: THIS PAGE INTENTIONALLY LEFT BLANK..
16 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. Printed in U.S.A. © 2006 by Lennox Hearth Products P/N 850,041M REV. A 02/2007 The manufacturer reserves the right to make changes at any time, without notice, in design, materials, specifications, prices and also to discontinue colors, styles and products.
An important point after buying a device Lennox Hearth LMBV-42REN (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Lennox Hearth LMBV-42REN yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Lennox Hearth LMBV-42REN - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Lennox Hearth LMBV-42REN you will learn all the available features of the product, as well as information on its operation. The information that you get Lennox Hearth LMBV-42REN will certainly help you make a decision on the purchase.
If you already are a holder of Lennox Hearth LMBV-42REN, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Lennox Hearth LMBV-42REN.
However, one of the most important roles played by the user manual is to help in solving problems with Lennox Hearth LMBV-42REN. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Lennox Hearth LMBV-42REN along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center