Instruction/ maintenance manual of the product KPOE-800-1P KTI Networks
Go to page of 17
Modular 8-Port Mid-span Power over Ethernet Injector KPOE-800-1P KPOE-800-2P Installation Guide 1 DOC.090201.
(C) 2008 KTI Networks Inc. All rights reserved. No part of this documentation m ay be reproduced in any form or by any mean s or used to make any di rective work (such as translation or transformation) without permission from KTI Networks Inc. KTI Networks Inc.
The information contained in this docu ment is subject to change without prior notice. Copyright (C) All Rights Reserved. TRADEMARKS Ethernet is a registered trademark of Xerox Corp.
Table of Contents 1. Introduction ............................................................................................................................... .5 1.1 Features .........................................................................
1. Introduction The Power over Ethernet (PoE) injector is a mid-sp an power injector designed and tested for use with all IEEE802.3af compatible PoE Powered Devices (PDs ). The PoE injector sits between a switch port and the PoE powered device, providing inline pow er capability to an un-powered switch port.
Modular PoE power upgradability 19" rack mounting support 1.2 Product Panels The following figure illustrates the faces of the injector: 1.3 Mid-span Injector Function The PoE mid-span power injector is designed and t ested for use with all IEEE802.
1.4 Model Definition KPOE-800-1P 1 Power Model The injector unit with one pre-installed power module KPOE-800-2P 2 Power Model The injector unit with two pre-installed power modules KPOE-800P60W Power.
8 - Disconnection, - Overload, - Over-current - Short-circuit, - Under voltage Power Module Slots 2 LED Indicators Power module status x 2 , Port PoE status x 8 Power Input Voltage: 100 ~ 240VAC, Frequency: 50/60Hz Power Consumption 1 Power Model: 68W max.
9 2. Installation 2.1 Unpacking Check that the following components have been included: Information CD The device unit An AC power cord If any item is found missing or damaged, please contact your local reseller for replacement.
2.3 Mounting the Injector Desktop Mounting The injector can be mounted on a deskto p or shelf. Make sure there is proper heat dissipation f rom and adequate ventilation around the device. Do not place heavy objects on the device. Rack Mounting The following brackets are designed for u se to mount the devices in a 19” rack.
2. Install the long bracket to the other side of the device. 3. Mount the device in a 19” rack. Mounting two units in a rack Use the bracket set 2 and follow the steps shown below: Short bracket x 4 Joint bracket x 1 1. Install two short brackets to both sides of each device.
3. Mount two device units as one in a 19” rack. 2.4 Installing Power Module If you purchased 2 Power Model, you may skip this section. 1 Power Model can deliver total up t o 60W for consuming by all eight ports. Calculat e the total power budget required for your PD connections before making any connections.
3. Install the power module into the slot until it is seated properly. 4. Screw the module in the injector securely. 2.5 Applying AC Power One AC power cord, which meets the specification of your country of origin was supplied with the device unit.
3. Making LAN Connections 3.1 Making Switch Port Connections The mid-span injector is designed to support th e following PoE incapable switch port t ypes and the PoE function is transparent and independe nt to the following port configuration: IEEE 802.
3.2 Making Powered Device Connections The mid-span injector supports connection to I EEE 802.3af compliant PoE PD (Powered Device). The Ethernet port of the PD can be Ethernet, Fast Ethe rnet or Gigabit Ethernet. The injector’s PoE OUT port delivers power together with network signal to a connected powered device via Cat.
Short-circuit A short-circuit situation is detected on the port. Under voltage An under-voltage situation is detected on the port. 3.3 LED Indication LED Function State Interpretation P1 Power 1 status ON Power 1 is ON. OFF Power 1 is OFF. P2 Power 2 status ON Power 2 is ON.
4. Applications 4.1 Application with Low Power Requirements 1 Power model may be used if the total power budge t of the connected PDs is less than 60Watts. One empty slot can be upgraded with one more power if total power budget increased and is more than 60W in future.
An important point after buying a device KTI Networks KPOE-800-1P (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought KTI Networks KPOE-800-1P yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data KTI Networks KPOE-800-1P - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, KTI Networks KPOE-800-1P you will learn all the available features of the product, as well as information on its operation. The information that you get KTI Networks KPOE-800-1P will certainly help you make a decision on the purchase.
If you already are a holder of KTI Networks KPOE-800-1P, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime KTI Networks KPOE-800-1P.
However, one of the most important roles played by the user manual is to help in solving problems with KTI Networks KPOE-800-1P. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device KTI Networks KPOE-800-1P along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center