KOBE Brand Range Hood Model No.: CH013 0SQB CH013 6SQB CH014 2SQB CH014 8SQB CH-101 SERIES – 18” HEIGHT I N S T A L L A T I O N I N S T R U C T I O N S A N D O P E R A T I O N M A N U A L.
.
- READ AND S A VE THES E INSTRUC T IONS - CONT ENTS IM PORTANT SAF ETY I NSTRUC TIONS.................................................................................... 1 COM PONENTS OF PA CKAG E ......................................................
1 IMPORTANT SAFETY INSTRUCT IONS - PLEASE READ T HIS SECT I O N CAR EFUL L Y BEFORE INSTALLATION - WARNI NG : TO REDUCE T HE RISK OF F IRE, ELECT RIC SHOCK OR PERSONAL INJUR Y , OBSERVE THE F OLLOWING.
2 W hat to Do In The Event Of a Range T op Grease Fire - SMOTHER FLAMES with a c lo se fitting lid, cookie sheet, or m e tal tra y , and then tu rn off the burn er . KEEP FLAMMABLE O R COMBUST IBLE MA TERIAL A W A Y F ROM FLAMES. If the fl ames do no t g o out i mm edi a tel y , EV ACUA T E THE AR EA AND CALL T HE F IR E DEP AR T MENT or 91 1.
3 COMPONENTS OF PA CKAGE (Must keep a ll materi al for returns or re funds) O P T I O N A L R E C I R C U L A T I N G K I T A L S O A V A I L A B L E . F O R M O R E I N F O R M A T I O N , P L E A S E V I S I T O U R W E B S I T E W W W . K O B E R A N G E H O O D S .
4 INS T ALLATION PLEASE READ ENTIRE INSTRUCT ION BEFORE PROCEEDING Calculatio n before Installat ion To cal culate installation , p l ea se refer to Table 1.
5 SAFETY WA RNIN G HOOD MAY H AVE VER Y SH ARP E DGES; PL EASE W E AR PROT ECT IVE G LOVES IF REMOVING ANY PART S FOR INST ALLING, CLEA N ING OR SERV ICING. N OT E: USIN G ELE CTRICA L SCREWDRIVERS MA Y CAU SE DAMAGE TO THE HOODS. I nst allation T ab le of C ontent s UN DE R THE CA BI N ET IN ST A LLA T IO N .
6 UNDER T HE CA B INE T INS T A LLAT ION Preparatio n Before Installat ion NOTE: TO AVOID DAM A GE TO YOUR HOOD, PREVE NT DEBRIS FROM ENTERING THE VENT OPENING. • Decide th e lo cation of the ve nting p i pe from t he hood to the outside. Refer to Figure 1.
7 Ductwork Installat ion 7. Use 8” a luminum o r st eel p ipe ( fo llow bu ildi ng codes in your a rea) to c onnect the duct i ng transi tion on the hood to the duct w ork above.
8 15. I nstall he ati n g l amps ( not p r ovi ded), 120 Volt s 25 0 Watt s m ax. e ach. 16. T urn powe r ON in control panel. Check all lights and fan operation.
9 ST AND A LO NE INST A LL ATION * * * F ol l o w th e se i ns t a l l a ti o ns o n l y i f i n s t a l l i n g wi t h a n o p t i o n al d u c t c o v e r : Preparatio n Before Installat ion NOTE : TO AVOID DAM AGE TO YOUR HO OD, PRE VENT DEBRI S FROM ENT E RIN G TH E VENT OP E NIN G.
10 2. Alig n hoo d -m oun ting b rac ket to the t w o screw s on the wall and hook hood in t o p la ce. Ti ghte n scr ews to s ec u re hood t o t he wall . 3. For sa f et y purp ose, extr a knocko ut holes on th e back of the ho od are provi ded fo r a m o r e se cure inst all ati o n.
11 Duct Cover Installat ion 5. Use 8” a luminum or steel pipe (follow building codes i n y ou r area) to co nnect the ducting transition o n the hood to the ductwork abo ve . Use duct t ape to seal and secure joints as show n in Figu r e 15 . Sl i de t he du ct cover onto t he hoo d.
12 OPER A TING INSTRU CTIONS This KOBE h ood i s equipped with touch-sensor screen and fe atures 3 m i nu te d el ay shu toff, powerful centrifug al squirrel cage with baff le fil ters, b right 12- volt 20-watt ha lo gen li gh ts a n d heatin g lam p cap abili ty (heating lam ps not i ncluded).
13 Turn Off After 3 Minute Delay Gently touch the symbol under the Power Control s i g n o n c e , t h e symbol f l a shes and a f t e r 3 m i n u t e s , the ho o d w i l l t u r n o f f l e a v i n g o n l y t h e sign li t . Sp e e d C o n t rol : • There are four speeds: QuietM ode™, Low, Medium, and High.
14 M A INTEN A NCE SAFETY WA RNIN G NEVER PUT YOUR HAND INTO AREA HOU SIN G T HE F AN WHILE THE F AN I S OPERAT ING. For opt imal op eration, clea n range hood surface an d stainless steel baff le filters regularly. Cleaning Hoo d Surface CAUTI ON : NEVER USE ABRASIVE CLE ANERS, PADS, OR CL OTHS.
15 Cleaning Stainless Oil T unn e l, Baf fle Filters and Spa cers CAUTI ON : DR AIN OIL BEFORE RES IDUE CAN OVERFLOW. 1. Re move the baf fle filter (reverse the order of baffle installati on). 2. Car efully r em o ve oil tunnel. 3. Di scard oil an d residue.
16 SPECIFICA TIONS CH0130SQB / 30“ CH0136SQB / 36“ CH0142SQB / 42“ M O DEL / S IZE CH0148SQB / 48“ COLOR #304 C ommercial Grade S tainl e ss S teel CONSUMPTI O N / AM PERE 900W / 8 A VOL T AGE.
17 ME A S UREMENTS & DIA G R A M S *** In c h measurements co nverted from millimete r. In c h meas urem e nts are e stimated. - F O R U N D E R T H E C A B I N E T - MODEL NO: CH0130SQB CH0136SQB CH0142SQB CH0148SQB 3 0 " / 3 6 " / 4 2 " / 4 8 " 3 - 1 / 8 " ( 7 9 .
18 - F O R U N D E R T H E C A B I N E T – ( C o n t . ) 2 - 5 / 8 " ( 6 6 ) 1 - 1 / 4 " ( 3 2 ) 6 - 1 / 2 " ( 1 6 5 ) 5 - 5 / 8 " ( 1 4 3 ) 1 0 - 3 / 4 " ( 2 7 3 ) 8 - 5 / .
19 - FO R STAND ALONE ( W ITH OPT IONAL DUCT COVER) – MODEL NO: CH0130SQB CH0136SQB CH0142SQB CH0148SQB 3 0 " / 3 6 " / 4 2 " / 4 8 " 3 - 1 /8 " (7 9 . 5 ) 2 4 " ( 6 1 0 ) 1 8 " (4 5 7 ) 1 8 - 7 /8 " ( 4 8 0 ) 1 9 - 1 / 3 " (4 9 1 ) 1 - 1 / 4 " ( 3 2 ) 1 2 " ( 3 0 5 ) 6 " ( 1 5 2 .
20 - FO R STAND ALONE ( W ITH OPT IONAL DUCT COVER) – (Con t.) 3 0 " / 3 6 " / 4 2 " / 4 8 " 3 - 1 /8 " (7 9 . 5 ) 2 4 " ( 6 1 0 ) 1 8 " ( 4 5 7 ) 3 0 " ( 7 6.
21 Hood- Mounting Bracket 1" ( 2 5 .4) 4 " (1 0 2 ) 1 /2 " (1 3 ) 1 /3 " (8 . 5 ) 3 /1 6 " (5 ) 1/ 4" ( 6 .5 ) 1 1 /1 6 " (1 7 .
22 P A RTS LIST MODEL NO: CH0130SQB CH0136SQB CH0142SQB CH0148SQB BODY COMPONENT S NO. DESCRIPTI ON MODEL/SIZE PART NO. 1 Hood Casing CH101-1 2 Ducting Tran si tion CH101-2 3 Screws (3/16 ” x 3/8 .
23 1 2 3 4 5 9 3 8 1 0 1 1 6 1 2 1 3 1 4 1 7A 1 6 1 8 1 9 2 0 2 1 7 1 7B 1 7 1 5 2 2 2 3 Optional Duct Cover ( Sold Separately) 2 4 3.
24 Blower Assembly NO. DESCRIPTION MODEL / SIZE PA RT NO. 4.1 Screws (3/16 ” x 3/8”) CH101-4.1 4.2 Air Flow Grill CH101-4.2 4.3 Left Locknut CH101-4.3 4.4 Left Squirrel Cage CH101-4.4 4.5 Motor CH101-4.5 4.6 Ri ght Squirrel Cage CH101- 4.6 4.7 Ri ght Locknut CH101- 4.
25 Electrical Assembly NO. DESCRIPTION M ODEL / SIZE PART NO. 21.1 Bolt CH10 1-21 .1 21.2 Elect rical Box CH10 1-21 .2 21.3 Screws (3/16” x 3/8”) CH10 1-21 .3 21.4 Pow er Boa rd CH10 1-21 .4 21.5 Elect rical Box Cover CH10 1-21 .5 21.6 Setup Boar d CH10 1-21 .
26 Switch Assembly NO. DESCRIPTION MODEL / SIZE PA RT NO. 20.1 Screen Support CH10 1-20 .1 20.2 Touch Scr een CH10 1-20 .2 20.3 Sw i tch Box CH10 1-20 .3 20.4 Sw i tch Boar d CH101-2 0.4 20.5 Sw i tch Box Cover CH10 1-20 .5 20.6 Screw s (1/8 ” x 1/2”) CH10 1-20 .
27 CIRCUIT DIAGRAM MODEL NO.: CH0130SQB CH0136SQB.
28 MODEL NO.: CH0142SQB CH0148SQB.
29 DIS CL AIMER 1. CAREFUL LY INSPECT ALL I T EMS FOR DAMAGES BEFO RE ACCEPTING DELIVERY. NOT E A NY D A MAGES O N T HE F REI GHT BI L L OR EXPRESS RECEIPT. REQUES T NAME A ND SIGNATURE O F T HE CA RRIER’S AGENT A ND KEEP COPY T O SUPPORT YOUR CLAIM.
30 WA RRANT Y WA RRANT Y CERTIFICA T E KOBE Rang e Hoods, Inc. w arr ants all produc ts manufactur ed or sup plied by i t to b e free fro m defect s in w or km a nshi p and materi als.
31 h) fo r da m a ge b y or re su l ting f rom atte m p ted repairs conducted by anyone other than our Aut horized Service Agent. 3) T he purcha ser sh all be r espo nsible fo r an y expenses i nvol v.
32 PRODUCT REGISTRA TION Regis ter Your Product! Any covere d failure occurrin g within t wo year s of original purch ase arising from defe ctive workmanship or m ate rial in m anu factur e will be r epaired o r at our option t he unit will be repla ced free of ch arge by an authorized KOBE Range Hood s Agent or KOBE Range Hoods a s applicable.
KOBE Range Hoo ds 10505 Valley Blvd Suite # 302 El Monte , CA 91731 USA http:// www.KOB ERa ngeH oods.c om This KOBE hood i s m ade fo r use i n the US A a nd CANADA o nl y . W e do not recomm end usi ng thi s hood ove rseas as t he pow er suppl y may not be com p ati bl e and may vi olate the el ectr i cal cod e of that country.
An important point after buying a device Kobe Range Hoods CH0148SQB (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Kobe Range Hoods CH0148SQB yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Kobe Range Hoods CH0148SQB - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Kobe Range Hoods CH0148SQB you will learn all the available features of the product, as well as information on its operation. The information that you get Kobe Range Hoods CH0148SQB will certainly help you make a decision on the purchase.
If you already are a holder of Kobe Range Hoods CH0148SQB, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Kobe Range Hoods CH0148SQB.
However, one of the most important roles played by the user manual is to help in solving problems with Kobe Range Hoods CH0148SQB. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Kobe Range Hoods CH0148SQB along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center